Operating Instructions

- With no air to the mask, screw the regulator adjustment knob all the way out and 

back in to be sure it turns freely.

2.4 Clean The Face Port

Remove any sand or debris from the interior of the mask and face port which may 

interfere with the divers vision, be inhaled, or blown into the divers face.

Under certain conditions, depending upon water temperature, you may find it 

necessary to prep the mask lens to keep it from fogging while diving. There are 

a number of commercial defoggers available for scuba diving which work well. 

Follow the directions on the label for use. If no commercial preparation is available 

it is possible to use soap. Use a small amount of liquid soap on a rag and smear a 

thin film on the inside of the lens. Do not rinse this film off. Apply the soap just 

prior to entering the water.

2.5 Adjusting The Equalizer

The Equalizer can easily be adjusted. Simply peel the Equalizer out of the Wire 

Retainer and reposition it in another one of the molded grooves in the Equalizer. 

The Wire Retainer can also be slightly bent in one direction or another, up or 

down, to get the angle of the Equalizer just right. Insure that the corners of the 

Equalizer grooves are “snapped” into position on the Wire Retainer so that it does 

not come loose.

2.6 Checking Regulator Functions And Preparing The Mask For Use 

Attach the low pressure hose that is supplied with the mask, to the low pressure 

(L.P.) port on the 1st stage regulator and then to the mask. Never connect the hose 

or mask to a high pressure (H.P.) port. When attaching the hose to the regulator 

ALWAYS USE A BACK UP WRENCH ON THE NIPPLE TUBE.

B

 

CAUTION

A backup wrench must be used on the hex fitting of the regu-

lator when tightening. Otherwise the regulator may come out 

of adjustment!

Prior to attaching the first stage regulator to your tank, be sure the regulator adjust-

ment knob on the mask is screwed all the way in. This will prevent the regulator 

from free flowing when the air is turned on.

Your first stage regulator shall be equipped with a safety device such as a submers-

ible pressure gauge. Attach the first stage to your tank and turn the air on while 

Содержание EXO-26

Страница 1: ...c All rights reserved This manual is made available for the express use of owner of this Kirby Morgan product No part of this manual may be reproduced stored in any retrieval system or transmit ted or...

Страница 2: ...You must have a return authorization from KMDSI prior to the return of any item Upon approval from KMDSI return the defective part freight prepaid to the KMDSI plant The part will be repaired or repla...

Страница 3: ...stand these sections B DANGER This word indicates an imminently hazardous situation which if not avoided could result in death or serious injury B WARNING This word indicates a potentially hazardous s...

Страница 4: ...15 2 5 Adjusting The Equalizer 15 2 6 Checking Regulator Functions And Preparing The Mask For Use 15 2 7 First Stage Regulator 17 2 8 Overpressure Relief Valve 17 2 9 Recommendations For Donning Or Re...

Страница 5: ...ob requirements improper maintenance or acts of God If you have any questions concerning this manual contact KMDSI 805 928 7772 or by Email at info KMDSI com or Dive Lab Inc 850 235 2715 or at Divelab...

Страница 6: ...OUS and could lead to serious accidents and or death Use of this equipment by a person who does not possess certification issued by an appropriate organization renders void any guarantee express or im...

Страница 7: ...er ice In order to reduce the risks of regulator freezing when diving in cold water below 10 C consider doing the following 1 Protect your regulators from any accidental ingress of water into the firs...

Страница 8: ...cylinder cylinders b Demand regulator c Safety device e g pressure gauge computer or reserve or alarm d Carrying frame or holding device for air cylinder s to mount the harness or carrying system e g...

Страница 9: ...Kirby Morgan Dive Systems Inc All rights reserved Document 120613002 9...

Страница 10: ...or The regulator is fully adjustable over a wide range of operating pressures By simply turning the Adjustment Knob while diving you can tune your regulator for your type of diving 2 EXOthermic Exhaus...

Страница 11: ...mply remove the mounting nut and push the entire module to the inside of the mask The earphones can then be removed A spare comm set is recommended for rapid replacement in the field if needed 7 Oral...

Страница 12: ...or ice diving operations and has been used successfully in the Arctic under subzero conditions It is an ideal mask for light commercial work for the diving scientist and for search and rescue operatio...

Страница 13: ...ryl Hardware Stainless Steel Chromed Brass O Rings Buna N Spider Neoprene Equalizer Urethane Recommended Lubricant Silicone Grease Dow Corning 111 Balanced EXO 26 Regulator Operating Pressures 115psi...

Страница 14: ...ore You Dive Before dressing in for a dive an inspection of the mask and all related gear should be made to insure everything is in proper working order This should be done well in advance of the dive...

Страница 15: ...Retainer and reposition it in another one of the molded grooves in the Equalizer The Wire Retainer can also be slightly bent in one direction or another up or down to get the angle of the Equalizer ju...

Страница 16: ...145 psi Higher first stage regulator pressures may cause free flow but turning the regulator adjustment knob in should stop the flow In the unlikely event there is still flow proceed to the regulator...

Страница 17: ...egulator and the second stage could increase until the hose ruptures This will cause a complete loss of the air supply It could also lead to injury of the diver due to the whipping action of the hose...

Страница 18: ...s natural correct position Do not try to force the buckles to swivel completely around They are allowed free but limited movement to keep the spider from becoming entangled while the mask is being han...

Страница 19: ...suit hood you may want to trim material from the cheek bone downward to under the front part of the chin When using a dry suit with a latex hood no adjustment should be needed How ever if the hood cov...

Страница 20: ...Inc All rights reserved Document 120613002 Operating Instructions A small hole can be punched in the top of the hood to relieve any build up of air inside Put the hole or holes on either side of wher...

Страница 21: ...ompensate for work rate depth diver position or affects of current or turbulence on the diaphragm The most noticeable difference in breathing resistance can be found in a face up position Resistance i...

Страница 22: ...aced underwater it must be cleared of water purged This is done by simply holding the mask firmly on the face keeping the regulator in a low position and depressing the purge button A slight momentary...

Страница 23: ...the regulator 4 Purge the regulator and try to get as much water out of it as you can then blow dry the mask with compressed air or let air dry completely 5 Disconnect the regulator and turn the adju...

Страница 24: ...tools must be purchased KMDSI highly recommends that Balanced EXO 26 rebuilds face seal replacements and frame replacements be done by a factory trained authorized dealer 4 4 STORAGE AND TRANSPORT OF...

Страница 25: ...he diver entering the water Procedures will vary between types and manufacturers of communications systems Follow the manufacturer s instructions on how to test these units 5 3 POST DIVE If your mask...

Страница 26: ...e covers and from under the module cover 3 Dry the assembly off Open the earphone covers take the module cover off and let everything on the inside dry 4 Once everything is dry reassemble the earphone...

Страница 27: ...REARENOOTHERWARRANTIES EXPRESSORIMPLIED INCLUDING BUTNOTLIMITEDTO ANYIMPLIEDWARRANTIES FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THE PRODUCT COVERED BY THIS WARRANTY IS MARKETED AND SOLD...

Отзывы: