ª,JSBNJ0Z'JOMBOE
5VCUBJOFSIFBUFSGJMUFSTZTUFN
P
AGE
16/17
ERRORCODES
This table explains error codes from faulty components or activated safety system.
Screen and state
of the heat pump
Component
Possible
Intervention
PP 01
Heater and pump
stopped
Water inlet
temperature sensor
Sensor
disconnected, non
supplied or
defective
Check the connections, the wires, change it
or replace the electronic card.
PP 02
Heater and pump
stopped
Heater protect
temperature sensor
Sensor
disconnected, non
supplied or
defective
Check the connections, the wires, change it
or replace the electronic card.
PP 03
The heater
continues running
Ambient air
temperature sensor
Sensor
disconnected, non
supplied or
defective
Check the connections, the wires, change it
or replace the electronic card.
PP 05
Heater and pump
stopped
Water outlet
temperature sensor
Sensor
disconnected, non
supplied or
defective
Check the connections, the wires, change it
or replace the electronic card.
PP 07
First anti-frost
protection active
Low temperatures
for water and air
No action required.
PP 07
Second anti-frost
protection active
Low temperatures
for water and air
No action required.
EE 01
Heater and pump
stopped
Heater overheating
protection
Insufficient water
flow
Check the water flow.
Overheating
protection switch
out of order
Replace the overheating
protection switch.
EE 03
Heater and pump
stopped
Flow switch
Insufficient water
flow
Check the water flow.
Switch is not
placed correctly
Check that the flow switch is correctly in
place so the arrow on the switch points the
way waterflow goes. Check
page 8. If adjustment is needed, loosen the
nut before turning the switch and tighten it
afterwards.
Flow switch
disconnected, non
supplied or
defective
Check the connections, the wires, change it
or replace the electronic card.
EE 06
Heater and pump
stopped
Heater protect
temperature sensor
Heater protect
temperature
detected up to
95°C more than 3
times in 1HR
Water flow is too small
piping has been blocked, check piping.
EE 08
The wire control
can't operated
Wire control
Communication
error
Signal cable of
wire
Control is loose
Check the connection of signal cable.
EE 09
Heater and pump
stopped
The outlet water
temperature is too
high for protection
Water flow rate
not enough
Water temperature
setting too high
Check the water flow rate, or water
system is jammed or not
Lower set temperature.
Содержание Tubtainer 2
Страница 13: ...JSBNJ 0Z JOMBOE 5VCUBJOFS TVPEBUJO M NNJUJO SIVU 11 17 VWB o SJ QBSBNFUSJU O ZU MM...
Страница 30: ...JSBNJ 0Z JOMBOE 5VCUBJOFS VOEFSI MMTW SNBSF SIDA 11 17 JME o 0MJLB QBSBNFUSBS Q EJTQMBZFO...
Страница 47: ...JSBNJ 0Z JOMBOE 5VCUBJOFS IFBUFS GJMUFS TZTUFN PAGE 11 17 NBHF o 1BSBNFUFST PO UIF TDSFFO...
Страница 64: ...JSBNJ 0Z JOOMBOE 5VCUBJOFS JMUFS FJ VOH SEITE 11 17 JME o JF WFSTDIJFEFOFO 1BSBNFUFS BVG EFN JTQMBZ...
Страница 81: ...JSBNJ 0Z JOMBOEF QQBSFJM EF GJMUSBHF DIBVGGBHF 5VCUBJOFS PAGE 11 17 NBHF JGG SFOUT QBSBN USF TVS Mh DSBO...
Страница 98: ...JSBNJ 0Z JOMBOE 5VCUBJOFS IFBUFS GJMUFS TZTUFN PAGE 11 17 GCFFMEJOH o 1BSBNFUFST PQ IFU EJTQMBZ...
Страница 107: ......
Страница 108: ......