Operation Manual

 

4Bank, Double & Single 

Select

Part No. 3100052 Rev A                                                                                          9-12-2013

Содержание Tegra 4Bank Universal

Страница 1: ...Operation Manual 4Bank Double Single Select Part No 3100052 Rev A 9 12 2013 ...

Страница 2: ...ixture 1 Mounting Plate 1 Extension Cable 1 Select Ballast 4Bank Double Single True Match Lamps 488 K29 S 4ft Kino KF29 488 K32 S 4ft Kino KF32 488 K55 S 4ft Kino KF55 242 K29 S 2ft Kino KF29 242 K32 S 2ft Kino KF32 242 K55 S 2ft Kino KF55 ...

Страница 3: ... Gaffer Ship Case Dimensions Weight 56 5 x 13 x 21 5 73 5 lb 143 5 x 33 x 55cm 33 5kg KIT 4804B 120 4ft 4Bank Kit 120VAC 1 Unit w Soft Case KIT 4804B 230 4ft 4Bank Kit 230VAC 1 Unit w Soft Case Kit Contents 1 4ft 4Bank System w MTP BL41 Mount 1 Lamp Case 1 Soft Case Dimensions Weight 55 x 8 x 19 5 26 lb 140 x 20 5 x 49 5cm 12kg Gaffer Kit 4ft 4Bank Kit ...

Страница 4: ...4B 230 2ft 4Bank Kit 230VAC 1 Unit w Soft Case Kit Contents 1 2ft 4Bank System w MTP BL41 Mount 1 Lamp Case 1 Soft Case Dimensions Weight 28 5 x 7 5 x 20 20 5 lb 72 5 x 19 x 51cm 9 5kg KIT 3NT 120 Interview Kit 120VAC 3 Unit KIT 3NT 230 Interview Kit 230VAC 3 Unit Kit Contents 1 2ft 4Bank System w MTP BL41 Mount 2 2ft Double System w MTP BL41 Mount 2 Lamp Case 1 Interview Ship Case Dimensions Weig...

Страница 5: ... must match at each end of the lamp for proper operation To Release the Lamp Harness Remove the harness from 2 clips located under the reflector Rotate the turn fastener clockwise to release harness The lamps can operate independent of the fixture allowing them to be built into sets or custom soft boxes or hand held as a single tube for an eye light WARNING Always use safety coated lamps to avoid ...

Страница 6: ... lamp Push lamps into the fixture s Lamp Holder Clips Restricting the airflow around the lamps can cause the lamps to operate hotter This increased heat will raise the lamp s color temperature and green spike Therefore it is recommended to clip gels to the doors of the fixture Do Not clip gels to louver Do Not block the fixture ends in a manner that restricts airflow ...

Страница 7: ...e loops provide attachment points for a safety chain To remove the plate pull up on the locking pin and reverse the mounting procedure A 180 turn loosens the orientation of the mount A right turn tightens the mount The tension on the lock lever may be adjusted by pulling the handle away from the mount This disengages the handle from the screw mechanism and allows the lever to be reoriented You can...

Страница 8: ... high frequency of 25kHz It is dead quiet instant on and lightweight Load Considerations Kino Flo ballasts are not power factor corrected They will draw double the current on the neutral from what is being drawn on the two hot legs On large installations it may be necessary to double your neutral run so as not to exceed your cable capacity Cold Temperature Operation The Select Ballast series is de...

Страница 9: ...ure when dropping from 4ft to 2ft It is not recommended to operate 2ft lamps in the 4ft setting At the 4ft setting the color temperature of the 2ft lamps will rise dramatically and experience a high green spike Extension Cable To insert the cable position the logo up to align the key ways on the extension cable with the circular receptacle on the ballast Rotate the locking ring until it clicks int...

Страница 10: ...nsion Cable 25ft X09 25 Double Extension Cable 25ft X04 25 Single Extension Cable 25ft True Match Lamps 488 K29 S 4ft Kino KF29 488 K32 S 4ft Kino KF32 488 K55 S 4ft Kino KF55 242 K29 S 2ft Kino KF29 242 K32 S 2ft Kino KF32 242 K55 S 2ft Kino KF55 BAL 415 120 Select 4Bank 120VAC BAL 415 230 Select 4Bank 230VAC BAL 215 120 Select Double 120VAC BAL 215 230 Select Double 230VAC BAL 105 S120 Select Si...

Страница 11: ...Flozier Half DFS D4 2ft 4Bank Flozier Full DFS D4 H 2ft 4Bank Flozier Half DFS D2 2ft Double Flozier Full DFS D2 H 2ft Double Flozier Half LVR 4804 B 4ft 4Bank Louver Black LVR 4802 B 4ft Double Louver Black LVR 4801 B 4ft Single Louver Black LVR 2404 B 2ft 4Bank Louver Black LVR 2402 B 2ft Double Louver Black LVR 2401 B 2ft Single Louver Black HAR 4804 4ft 4Bank Harness HAR 4802 4ft Double Harnes...

Страница 12: ... Rcvr 16mm MTP LBS Kino 41 Lollipop w Baby Rcvr Short 16mm X16 A4 4Bank to Single Splitter X16 A9 4Bank to Double Splitter X09 A4 Double to Single Splitter X09 A16 Double to 4Bank Combiner X04 A16 Single to 4Bank Combiner X04 A9 Single to Double Combiner MTP BL41 Kino 41L Mount w Baby Receiver 16mm MTP BL41S Kino 41L Mount w Baby Rcvr Short 16mm X16 12 4Bank Extension Cable 12ft X09 12 Double Exte...

Страница 13: ...air Kit Silver EXP M T Adhesive Mounts Releasable Ties 25pk PRT CR4 4Bank Connector Locking Ring 4pk PRT CR2 Double Connector Locking Ring 4pk PRT CR1 Single Connector Locking Ring 4pk PRT HLC Kino Locking Lamp Connector 1pk See our website at www kinoflo com for more repair parts ...

Страница 14: ...33 5 x 28 x 30 5cm 16 lb 7 5kg 4ft Lamps 20 KAS 54L 4ft Fixture Ship Case Large 57 5 x 15 x 17 146 x 38 x 43cm 25 5 lb 12kg 4ft 4Bank Fixtures 5 KAS 54S 4ft Fixture Ship Case Small 57 5 x 15 x 12 146 x 38 x 30 5cm 21 lb 9 5kg 4ft 4Bank Fixtures 3 KAS C26 6 Lamp Carry Case 2ft 26 5 x 6 x 4 67 5 x 15 x 10cm 1 lb 5kg 2ft Lamps 6 KAS C46 6 Lamp Carry Case 4ft 50 5 x 6 x 4 128 5 x 15 x 10cm 1 5 lb 7kg ...

Страница 15: ...re Style Length Width Depth Barndoor Width Weight w Lamps 4ft 4Bank 52 13 3 5 6 5 11 5 lbs 2ft 4Bank 27 13 3 5 6 5 7 5 lbs Lamp Type Length Width 4ft Med Bi Pin 48 5 1 5 2ft Med Bi Pin 24 5 1 5 Kino Flo Lamp w Harness Dimensions Kino Flo 4Bank Fixture Dimensions ...

Страница 16: ...s 4ft Double 52 7 5 3 5 6 7 7 lbs 2ft Double 27 7 5 3 5 6 4 7 lbs Fixture Style Length Width Depth Barndoor Width Weight w Lamps 4ft Single 52 4 5 3 5 3 5 4 3 lbs 2ft Single 27 4 5 3 5 3 5 2 6 lbs Kino Flo Double Fixture Dimensions Kino Flo Single Fixture Dimensions ...

Страница 17: ...A F40 1 8A Lamp Switching 1 4 Output Switching 4ft 2ft Ballast Size 13 x 9 5 x 3 33 x 24 x 7 6cm Weight 5 9lb 2 7kg BAL 215 120 Select Double Ballast 120VAC Input Voltage 120VAC 50 60Hz Output Frequency 25kHz Amperage F75 2 6A F40 1 8A Lamp Switching 1 2 Output Switching 4ft 2ft Ballast Size 9 x 9 5 x 3 23 x 24 x 7 6cm Weight 3 5lb 1 5kg BAL 215 230 Select Double Ballast 230VAC Input Voltage 230VA...

Страница 18: ...mp Switching 1 off Output Switching 4ft 2ft Ballast Size 11 x 2 5 x 2 5 28 x 6 5 x 6 5cm Weight 2lb 0 9kg BAL 115 230 Select Single Ballast 230VAC Input Voltage 230VAC 50 60Hz Output Frequency 25kHz Amperage F75 0 7A F40 0 5A F30 0 4A Lamp Switching 1 off Output Switching 4ft 2ft Ballast Size 10 5 x 4 x 3 26 5 x 10 x 7 6cm Weight 2 6lb 1 2kg ...

Страница 19: ...19 ...

Страница 20: ...c Equipment This symbol on the product or on its packaging indicates that this product shall not be treated as household waste This product is made of recyclable materials and should be disposed of in accordance with local and state regulations Kino Flo Inc 2840 N Hollywood Way Burbank CA 91505 USA Tel 818 767 6528 website www kinoflo com 20 ...