![Kino Flo ParaZip 200 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/kino-flo/parazip-200/parazip-200_operation-manual_1971377008.webp)
8
LAMPS FAIL TO LIGHT:
•
With the power switch in the
ON
position, the red light should be on. If it is not,
Voltage is not present. Check your power feed. Check the fuse on the fixture and
replace if necessary
(5 x 20mm, T3.15AH/250V, Time Delay Type)
•
The on board manual dimmer should be full up, turned completely clockwise.
•
Check lamp contact. Lamps must be properly seated. If one lamp is not making
contact or is burned out, two lamps will be off.
•
Replace lamp or lamps.
•
After having checked that lamps are correctly seated, turn off power to the fixture
for 60 seconds and restart.
•
With DMX cable connected, if yellow light is off, there is no DMX signal.
Establish a valid DMX signal.
•
With DMX cable plugged in and yellow indicator on:
1. Address must be between 001 and 512. Addresses above 512
are invalid.
2. The dimmer setting on lighting board must in the full up mode.
3. The last fixture must have the DMX termination switch set to
END
of LINE
. Numerous terminated fixtures on a DMX run will
result in DMX signal corruption.
Note: If a Fixture or Ballast loses its DMX signal it will hold its last
DMX command.
For this reason it is important to turn the Fixture or
Ballast off using the DMX commands. For example, if you try to turn off
the lights by turning off the dimmer board, the lights will remember their
last DMX command and stay on. The Fixtures or Ballasts require
a DMX “Off” or “Black-out” command in order to turn off.