MTP-B41F
… Baby offset arm
The Baby Offset Arm allows fixtures to mount
above the center of a stand or to be under
slung from a baby stand.
10
LAMPS FAIL TO LIGHT:
•
Check ambient temperature. If below 60 degrees F, the unit might
have trouble starting.
•
With the power switch in the
ON
position, the red light should be on. If
it is not, Voltage is not present. Check your power feed.
•
The onboard dimmer should be full up. (Turned completely clockwise.)
•
Check lamp contact. Lamps must be properly seated. If one lamp is
not making contact or is burned out, two lamps will be off.
•
Replace lamp or lamps.
•
After having checked that lamps are correctly seated, turn off power to
the fixture for 60 seconds and restart.
•
Check that the lamp selector switch is in the appropriate setting.