background image

 Page 7 of 12

Figure.3 Immersion wiring, a) layout of immersion wiring terminals, b) wiring diagram.

Only immersion heaters with a thermal over temperature saefty cut out  may be used. The immersion heaters have a 1-1/4” 

NPT thread. Thread will have to be sealed with appropriate compound/tape. They are rated at 4.5 kW at 240 V and are of 

a low noise Incoloy construction. The thermostat should be set to limit the temperature to a maximum of 185˚F (85˚C). It is 

recommended that that the water temperature is set for the lowest temperature that satisfies your hot water needs. Setting 

the temperature to 120˚F will reduce the risk of scalds. Please order the correct replacement via Kingspan Solar; fitting non-

approved heating elements may affect your warranty. 

If no immersion heater is to be installed, it is recommended that a brass 1-1/4” plug be used.

The cable must be copper 10AWG heat resistant compliant with the National Electrical Code, ANSI/NFPA 70. The heaters 

must be connected to a dedicated branch circuit with the relevant protection devices. The cable must be connected to a field 

wiring terminal that is rated for the immersion heater current load. The unit must be grounded to a properly installed ground 

circuit using an appropriate field terminal.

Check the immersion heaters are 240V and rated at 4500W this should be stated on the case.

Figure 3 shows the layout and wiring schematic of the heating element. To access the wiring terminals, firstly, remove the 

temperature dial by gently pulling of the dial completely off, then loosen the three retaining screws on the edge of the cover 

and slide the red cover off the unit.

The terminals are set up for single phase 240V series operation. 

The 1L1 wire is white and the 1L2 wire is black. The green stud, refer to Figure 3 a) shows the grounding connections. Use 

correct wire connections and ensure a proper gland/grommet is used to exit the immersion heater casing

WARNING

The tank must be full of water before any power is switched on. Heating elements will be damaged if powered in air.

2.3 IMMERSION HEATERS

WARNING: Use a qualified electrician to install the KINGSPAN TRIBUNE hot water tank. The tank must be electrically 

wired in accordance with these instructions and the relevant local codes. If local codes do not apply consult the National 

Electrical Code.

HAZARD OF ELECTRIC SHOCK! Any installation involving electric heaters must be grounded to earth to eliminate shock 

hazard.

Содержание Tribune

Страница 1: ...IMPORTANT NOTE TO THE INSTALLER Read these instructions before commencing installation Installation Manual For Kingspan Tribune USA Issue 4 Sept 2010 Part No BOOKSTAINULT Page 1 of 12 Tribune ...

Страница 2: ...ate this water heater if it is not working properly or if it has been damaged or dropped 8 This water heater should be serviced only by qualified service personnel Contact nearest authorized service facility for examination repair or adjustment SAVE THESE INSTRUCTIONS DANGER Very Hot Water can cause serious injury or death Ensure that you comply with the instructions contained within this manual a...

Страница 3: ...t maximum of 2 The pan should be connected to drain by a bore drain Consult a certified plumber for more information The KINGSPAN TRIBUNE should be located near to a drain to allow the drainage of water during maintenance and as an outlet for the safety equipment located on the unit The KINGSPAN TRIBUNE tank can supply outlets above it or at some distance from it Site the unit to minimise dead leg...

Страница 4: ...s allows a variety of heat sources to be used In the single coil configuration this can be connected to a boiler or solar circuit Twin coil tanks the lower coil is connected to a solar circuit and the top coil to a boiler system Figure 1 shows a schematic of the tank configuration Page 4 of 12 Figure 1 Single and Twin coil configurations ...

Страница 5: ...d water system meaning that thermal expansion may cause a pressure build up within your hot water tank In such a case an expansion tank must be fitted to allow for any excess pressure caused by thermal expansion Please see figure 2 for reference Water pressure If the incoming water pressure is over 80 PSI a pressure reducing valve Water pressure regulator must be fitted This is to be located on th...

Страница 6: ...e The hot water tank has a NPT female connection to accommodate this apparatus in the top of the tank CAUTION To reduce the risk of excessive pressures and temperatures in this water heater install temperature and pressure protective equipment required by local codes but no less than a combination pressure valve certified as meeting the requirements for Relief Valves and Automatic Gas Shutoff devi...

Страница 7: ...r the immersion heater current load The unit must be grounded to a properly installed ground circuit using an appropriate field terminal Check the immersion heaters are 240V and rated at 4500W this should be stated on the case Figure 3 shows the layout and wiring schematic of the heating element To access the wiring terminals firstly remove the temperature dial by gently pulling of the dial comple...

Страница 8: ...pen every other hot faucet in turn to purge all remaining air 3 1 FILLING If the tank is to be heated by an indirect boiler consult the boiler manufacturers commissioning instructions and fill the primary circuit accordingly Two port valves and tank thermostats may need to be used to control input into the KINGSPAN TRIBUNE unit 3 2 INDIRECT UNITS During heat up there should have been no sign of wa...

Страница 9: ...3 4 INSTALLATION CHECKLIST FLOW CHART Page 9 of 12 Figure 4 Check list of installation steps ...

Страница 10: ...me as the annual boiler or solar system service 1 Lift the lever on the expansion relief valve on the inlet control set and allow water to flow for 5 seconds Release and make sure it resets correctly Repeat with the pressure temperature relief valve In both cases check that the discharge pipe work is carrying the water away adequately If not check for blockages etc and clear WARNING THE WATER DISC...

Страница 11: ...er than by kingspan It has not been misused tampered with or subjected to neglect It has only been used for the storage of potable water It has not been subjected to frost damage The unit has been serviced annually The guarantee period starts from the date of purchase and no registration is required The guarantee is not transferable and rests with the original householder The system is fed from a ...

Страница 12: ......

Отзывы: