background image

 

 

 

GL0016P 

INSTALLATION GUIDELINES 

FOR BIODISC

®

 UNITS 

BF, BG, NF & NG 

 

 

Contact Numbers: 
 
UK: 
Service Tel: +44 (0) 845 355 0555 
Service Fax: +44 (0) 1264 325245 
 
Ireland: 
Service Tel: +44 (0) 28 302 54077 
Service Fax: +44 (0) 28 302 60046 
 

 

 

 

 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

BioDisc is the registered trademark of Kingspan Environmental. 

510031P

 

BF Single Phase Panel Wiring Diagram

 

The following wiring diagrams are provided with in the control panel housing.          

If additional copies are required contact Kingspan.

 

510030P

 

BF  3 Phase Control Panel Wiring Diagram

 

510003P

 

BF 3 Phase Alarm Control Panel Wiring Diagram

 

510017P 

BF Single Phase Alarm Control Panel Wiring Diagram 

510012P

 

BG, NF & NG Single Phase Panel Wiring Diagram

 

510013P

 

BG, NF, & NG Single Phase Alarm Control Panel (Option L/M) 

510006P

 

BG, NF & NG 3 Phase Control Panel Wiring Diagram 

510007P

 

BG, NF & NG 3 Phase Alarm Control Panel

 

510018P

 

Independent Loss of Rotation Alarm 

Issue Description 

Date 

02 CC841 

May 2010 

      Enclosed Documents

Содержание BF BIODISC

Страница 1: ...ith in the control panel housing If additional copies are required contact Kingspan 510030P BF 3 Phase Control Panel Wiring Diagram 510003P BF 3 Phase Alarm Control Panel Wiring Diagram 510017P BF Sin...

Страница 2: ...tails on request Should you wish to inspect the operation of the equipment please observe all necessary precautions including those listed below which apply to maintenance procedures BioDisc units con...

Страница 3: ...GL0016P 02 Installation Guidelines for BioDisc Units BF BG NF NG 3...

Страница 4: ...also inside units particularly if they have been stored on site prior to installation adding weight and increasing instability Check units before lifting and pump out any excess water 2 5 When lifting...

Страница 5: ...though not obligatory for an installation of this type RCD protection is suggested as an extra precaution 3 12 Pump stations or any other associated equipment should have a separate power supply 3 13...

Страница 6: ...support the installed load but not so much as to prevent subsequent backfill bonding fully to the base 5 4 Ensure that the slab is free of any stones or other material which could damage the unit Low...

Страница 7: ...panel Customer Supply Inlet Pipe Control Panel G L 600mm Inlet Invert Add 100mm For Outlet Invert Concrete backfill minimum 150mm thick but to suit specific site conditions Concrete Pea Shingle or oth...

Страница 8: ...control panel should be positioned adjacent to the unit so that a It does not interfere with cover removal b It is convenient for the incoming power supply c It cannot be reached by someone standing i...

Страница 9: ...han 100 metres from the BioDisc and that the interconnecting cable customer supply should be laid in a separate trench to prevent electrical interference 6 2 5 Connect the incoming power supply to the...

Страница 10: ...GL0016P 02 Installation Guidelines for BioDisc Units BF BG NF NG 10...