Trouble Shooting The Gas Control System

WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT.

NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position.

Problem

Possible Causes

Corrective Action

Spark igniter will not light.

Defective or misaligned electrode

Check for spark at electrode and pilot: if no spark and electrode wire is

at pilot.

properly connected, replace igniter.

Defective igniter

Using a match, light pilot. If pilot lights, turn off pilot and push the red

(push-button)

button again. If pilot will not light - check gap at electrode and pilot 
should be 1/8” to 1/4” to have a strong spark.

Pilot will not stay lit after carefully

Defective thermocouple

Check pilot flame. Must impinge on generator and thermocouple.

following lighting instructions.

(flame switch where applicable) 

Clean and/or adjust pilot for maximum flame impingement on
generator and thermocouple.

Defective valve magnet.

Replace valve

Pilot burning, no gas to burner,

Wall switch or wires

Check wall switch and wires for proper connections. Jumper wire

Valve knob “ON”, Wall

defective.

across terminals at wall switch. If burner comes on, replace defective

Switch “ON”

wall switch. If okay, jumper wires, across wall switch wires at valve.
If burner comes on, wires are faulty or connections are bad.

Generator may not be generating

Check generator with millivolt meter. Take reading at generator termi-

sufficient voltage.

nals of gas valve. Should read 325 millivolts minimum while holding 
valve knob depressed in pilot position and wall switch “off” Replace 
faulty generator if reading is below specified minimum.

Plugged burner orifice.

Check burner orifice for stoppage and remove.

Defective automatic valve

Remove wall switch wires from gas valve. Install jumper wires from 

operator.

top bottom terminals of gas valve. Turn valve on “ON”. If main burner
does not light, replace valve.

Frequent Pilot outage problem.

Pilot flame may be too low or

Clean and/or adjust pilot flame for maximum flame impingement

blowing (high) causing the pilot

on generator and thermocouple.

safety to drop out.

Flame lifts off burner and goes out

Inner 4” liner has come off flue

Attach 4” liner to flue or termination using      

in less than 30 seconds

or termination, flame is starving

screws, silicone and clamps as stated in manual

oxygen

Flame lifts off burner on

Improper installation of firebrick.

Be sure to postion firebrick against firebox walls and

one side while the rest of

Firebrick is likely leaning.

be sure to use brick clips attached to the inner side

the flame remains lit.

of firebox.

Содержание "Zero Clearance" ZDV1001

Страница 1: ...nce What To Do If You Smell Gas Do not try to light any appliance Extinguish any open flame Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier...

Страница 2: ...8 Vent termination 9 10 Venting graph 10 General vent installation information 11 Installation of top flue side wall venting 11 12 Installation of back vents 13 Repair parts list 13 Valve System Part...

Страница 3: ...vice person A professional service person should be called to inspect this appliance annually Make it a practice to have all your gas appliances checked annually 6 Control compartments burners and air...

Страница 4: ...llation recommendation when installing this fire place against non insulated exterior wall or chase it is recommend ed that the outer walls be insulated to conform to applicable insula tion codes Dryw...

Страница 5: ...pressure testing of the gas supply piping sys tem at test pressures equal to or less than 1 2 PSIG 3 5 KPa Note The gas line connection may be made of 1 2 rigid pipe 1 2 copper pipe or an approved fl...

Страница 6: ...should any solid fuels wood paper card board coal be used in this appliance Note It is normal for your gas fireplace to give off some odor the first time it is burned This is due to the curing of the...

Страница 7: ...plug on the inside wall of the access area opposite the fan Large holes are provided to allow wiring to enter the access area on the left of the unit Connect the power sensor and variable speed wall...

Страница 8: ...that turns the main burner on or off If main burner does not light immediately when you turn the gas control valve to ON ensure that the wall switch is in the ON position NOTE The On Off wall switch...

Страница 9: ...driveway located on public property 7 feet 2 1m minimum 3 V NOTE Clearances are to the terminal center line Add 6 inches to clearances not indicated as measured from center line NOTE Local Codes or R...

Страница 10: ...s are required the horizontal run length must be reduced to 7 feet How To Use The Vent Table 1 Determine the height of the system and the number of bends required 2 Having determined the vertical dist...

Страница 11: ...ing on the wall Cut a hole through the exterior wall allowing for a 11 x 11 minimum inside framing or an 8 1 2 diameter hole if venting through a non combustible wall Center wall thimble over 11 x 11...

Страница 12: ...NOTE At the top edge of the flashing plate lift the shingles and nail the plate to the roof deck then cement the shingles to the plate with a suitable waterproof mastic Ensure that the chimney is plum...

Страница 13: ...d must be cut to comply Install wall thimble Place fireplace into place and secure to floor with nailing tabs Step 5 Mount vent termination make sure 4 and 7 pipes are siliconed Caulk around wall thim...

Страница 14: ...urround Kits ZISAB Surround Antique Brass ZISPB Surround Polish Brass ZISAL Surround Almond ZISBG Surround Burgundy ZISGR Surround Green ZISSAB Surround Slim Line Antique Brass ZISSPB Surround Slim Li...

Страница 15: ...h ON wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Generator may not be generating Check generator with millivolt meter...

Страница 16: ...ing its stability or performance d damages caused by improper matching or application of the unit or the unit s components e damages caused by failing to provide proper maintenance and service to the...

Отзывы: