background image

Installation Instructions

Listed Certified for USA. and Canada

The ZDV3620 may be installed in an aftermarket permanently located, manufactured (mobile home), 

where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate.

This appliance is not convertible for use with other gases, unless a certified kit is used.

Model Number ZDV3620

Stock #’s: ZDV3620N and ZDV3620LP are Certified to:

ANSI Z21.88b-2003, CSA-2.33b-2003, CSA 2.17-M91, CSA P.4.1-02

Read this complete manual before beginning installation.

These instructions must be kept with the unit for future reference.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the

vicinity of this or any other appliance.

What To Do If You Smell Gas

Do not try to light any appliance.

Extinguish any open flame.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbour’s phone.

If you can not reach your gas supplier, call the fire department.

A Division of R-Co. Inc.

2340 Logan Avenue

Winnipeg, Manitoba, Canada  R2R 2V3

Ph: (204) 632-1962

Warning: 

Improper installation, alteration, service or maintenance can cause property damage, personal

injury or losses of life. Refer to this manual. Installation and service must be performed by a qualified
installer, service agency or the gas supplier.

Printed in Canada August 27, 2008 Part # 3620-MAN  

“Zero Clearance”

Direct Vent Gas Fireplace

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

Содержание ZDV3620

Страница 1: ...e vapors and liquids in the vicinity of this or any other appliance What To Do If You Smell Gas Do not try to light any appliance Extinguish any open flame Do not touch any electrical switch Do not us...

Страница 2: ...tory However due to the high temperature sili cone components the paint will cure when heat is applied to the appliance as it is first used The following information applies to the curing process to g...

Страница 3: ...ly 11 Fan kit installation 12 Millivolt system lighting burner control 13 Vent termination 14 Venting graph 15 General vent installation information 16 Installation of side wall venting 16 Venting ver...

Страница 4: ...is of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating to insure grounding Use carriage bolt at the attachment point see diagram above to secure...

Страница 5: ...n under water Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water 12 WARNING Do not opera...

Страница 6: ...terminal must be used and if applicable a Product approved air intake must be used Installation shall be in strict compliance with the manufacturer s instructions A copy of the installation instructi...

Страница 7: ...nt system does not exceed 20 feet 6 1m When you install your fireplace as in position B D or E a minimum of 6 inches 153mm clearance must be maintained from the perpendicular wall and the front of the...

Страница 8: ...appliance on the bottom sides and top of fireplace 4 When installing horizontal with a 90 degree bend maintain a minimum of four 21 2 inches above the bend in enclosures 5 Hearth is not mandatory but...

Страница 9: ...tel such paint or lacquer must be heat resistant 250 F to prevent discoloration Warning Combustible objects must not be placed on a non combustible mantel unless the non combustible mantel meets the m...

Страница 10: ...solution 8 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 PSIG 3 5...

Страница 11: ...of log must be shifted to the left against tab for proper log placement 4 Front log should be placed in front of burner up against log grate 5 Place right and left logs across front and back log in t...

Страница 12: ...eed switch from the wall mount Turn the variable speed wall controller to its minimum setting fully clockwise Use the set screw on the side of the variable speed controller to increase or decrease the...

Страница 13: ...pilot screw to provide proper sized flame Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire Size Max Length 14 GA 100 FT 16 GA 64 FT 18 GA 40 FT 20 GA 25 FT 22 GA 1...

Страница 14: ...al codes V NOTE Clearances are to the edge of terminal plate add 6 3 4 to clearances to arrive at center line NOTE Local Codes or Regulations may require different clearances Termination It is imperat...

Страница 15: ...f bends required 2 Having determined the vertical distance determine the maximum horizontal section allowed 3 Vent table has been established for 90 horizontal vertical runs With use of flex pipe dist...

Страница 16: ...xpanded to twice their lengths e g 4ft to 8ft Fully expand pipe and cut off excess Do not use more than 2 couplers to extend short pipes Single sections are preferred in an installation attaching at t...

Страница 17: ...of the roof slope under the shingles Both the sides and the lower edge lay on top of the shingles NOTE At the top edge of the flashing plate lift the shingles and nail the plate to the roof deck then...

Страница 18: ...ilder Antique Brass Z36GBC Grill Kit Classic Builder Chrome Z36GBP Grill Kit Classic Builder Polish Brass Z1GBL Grill Kit Black Z1GAB Grill Kit Antique Brass Z1GPB Grill Kit Polish Brass Z36GCR Grill...

Страница 19: ...DVSS Siding Shield ZDV48GP Galvanized Pipe 7 Dia x 48 Vertical Installations ZDVAAF Flashing 7 c w Storm Collar 1 12 to 7 12 ZDVAF2 Flashing 7 c w Storm Collar 8 12 to 12 12 ZDVAF3 Flashing 7 c w Stor...

Страница 20: ...minals at wall switch If burner comes on replace defective Switch ON wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Gener...

Страница 21: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...

Отзывы: