MQVL48 / MQVLBG48 Component Locations
DCHS Cover for Optional Remote Receiver-
Millivolt or Proflame 1 Systems Only
VALVE
P2
MODULE
LIGHT
DRIVER
(LED)
120 VAC
GAS LINE
120 VAC
OPTIONAL
PROFLAME 1
C/W REMOTE
RECEIVER &
DCHS BOX
Wall Mount Option
10ft. Extension Harness (Part No. 1001-P904SI)
required.
The Remote Receiver can be mounted
on a vertical wall stud using the DCHS as
a mounting bracket.
Ensure that the face is protruding 1/2” so
that the face plate will be flush on the
face of the wall.
Drywall cutout size is 2” wide by 4-1/8”
tall.
Must be installed within 10ft of valve
assembly (6ft recommended).
BATTERY
BACKUP
REMOTE PAIRING BUTTON
(SW1 SWITCH)
TOP VIEW
REMOTE PAIRING BUTTON
(SW1 SWITCH)
39