-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance

-WHAT TO DO IF YOU SMELL GAS

 

  Do not try to light any appliance. 

  Do not touch any electrical switch; do not use any phone in your building. 

  Leave the building immediately. 

  Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s 

instructions. 

  If you cannot reach your gas supplier, call the fire department 

-Installation and service must be performed by a qualified installer, service agency or the gas 

supplier.

 

INSTALLER: 

Leave this manual with the appliance.  

CONSUMER: 

Retain this manual for future reference. 

This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, 

where not prohibited by local codes. 
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use 

with other gases, unless a certified kit is used.

 

- Installation Instructions -

 

Model Numbers: 

Single Side Units: 

MQVL48N, MQVL48NE, MQVL48NE2, MQVL48LP, MQVL48LPE,  MQVL48LPE2 

 

Bay Peninsula Units: 

MQVLBG48N, MQVLBG48NE, MQVLBG48NE2, MQVLBG48LP, MQVLBG48LPE, MQVLBG48LPE2  

 

Certified to: ANSI Z21.88-2017/CSA 2.33-2017 and CSA2.17-2017 

VENTED GAS FIREPLACE HEATER

 

 

ENCLAVE 

 WARNING:  

FIRE OR EXPLOSION HAZARD

 

Failure to follow safety warnings exactly could result in serious injury, death, or property damage. 

A Division of R-Co. Inc. 2340 Logan Ave. 

  Winnipeg, Manitoba Canada R2R 2V3 Ph.: (204) 632-1962 

Printed in Canada December 9, 2019 Part# 48MQVLBG-MAN17 

VENTED GAS FIREPLACE HEATER:

 

NOT FOR USE WITH SOLID FUEL

 

 

WARNING:

 

DO NOT OPERATE THIS APPLIANCE WITHOUT 

DECORATIVE GLASS EMBERS ON BURNER AND MEDIA TRAY

 

- Certified for use with 

Adjustable Vented Platform

 (AVP), and 

Heat Distribution System

 (HDS) -  

Содержание MQVL48LP

Страница 1: ...des This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Installation Instructions Model Numbers Single Side Units MQVL48N MQVL48NE MQVL48NE2 MQVL48LP MQVL48LPE MQVL48LPE2 Bay Peninsula Units MQVLBG48N MQVLBG48NE MQVLBG48NE2 MQVLBG48LP MQVLBG48LPE MQVLBG48LPE2 Certified to ANSI Z2...

Страница 2: ...e to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children WARNING A HORIZONTAL VENT CERTIFIED GUARD SAFETY CAGE IS AVAILABLE WHEN REQUIRED BY LOCAL CODES SAFETY CAGES ARE AVAILABLE FOR ALL HORIZONTAL VENT TERMINATIONS CHECK WITH YOUR DEALER TERMINATION CAP IS HOT Do not pla...

Страница 3: ...d due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit 16 Clothing or other flammable material should not be placed on or near the appliance This appliance should not be used as...

Страница 4: ...Using Tile Lip 23 Facing Requirements 23 VL48S1BL VL48S1SS Surround Installation for MQVL48 24 25 MQVL48SEP Side Extension Panels 26 Glass Front Removal Installation 27 MQVLBG48 Bay Peninsula Locating Your Appliance 28 Fireplace Dimensions 28 Bay Peninsula Framing 29 Bay Peninsula Nailing Tabs and Framing 30 VLBGCK Corner Kit 31 33 Using Tile Lip 34 Facing Requirements 34 Front Glass Installation ...

Страница 5: ...figuration 2 Remote ON OFF and Manual HI LO Capabilities 63 Configuration 3 Remote ON OFF variable HI LO and Fan Capabilities 64 Operating the Receiver Without Batteries Millivolt and Proflame 1 65 Electronic Ignition Lighting Instructions 66 Proflame 2 Proflame 2 Parts List 67 Proflame 2 Module and Remote Control 68 Cold Climates CPI Setting Proflame 2 Remote Control 69 Proflame 2 Remote Control ...

Страница 6: ...fication plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to be easily read from a distance of eight feet away and read Gas Vent Directly Below 2 For direct vent appliances mechanical vent heating appliances or domestic hot water equipment where the bottom of the vent terminal and the air intake is i...

Страница 7: ...he sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can be reduced somewhat by turning down the speed of the fan with the variable speed control Be aware however that this will reduce the volume of heated air circulated into the room by the fan Note to th...

Страница 8: ... 1 Canadian National Electrical Code in Canada An appliance must be grounded to the steel chassis of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating to insure grounding Use carriage bolt at the attachment point see diagram above to secure the appliance to the floor For required venting components see venting installation in appropriate sectio...

Страница 9: ...or to the indoor gas fireplace being installed A Minimum sheltering cover overhang of 1 2 the distance from the base of the fireplace to the ceiling base of roofline is required EXAMPLE The bottom of the fireplace is 84 from the ceiling Therefore 42 of sheltering cover is required above fireplace All wiring connections to line power shall be in accordance with outdoor requirements of NECA NFPA 70 ...

Страница 10: ...tions are These stand offs are provided as indicators to illustrate the boundaries for framing Therefore no framing material is permitted to extend beyond these stand offs Vertical Venting in Cold Climates In cold climate conditions where temperatures go below 10 degrees Celsius or 14 degrees Fahrenheit we recommend that the chase be insulated and where the vent pipe enters into the attic space th...

Страница 11: ...an and free of all debris i e loose insulation pieces of wood etc Framing for Vented Chase with Grills Framing for Vented Chase with Openings No Grills 84 Sq In Air Option Fireplace Support must be open to allow air to flow through fireplace Required Minimum 151 Sq In Free Air Uses Kingsman VL48EG Grill Or Minimum 151 Sq In Free Air Equivalent Required Minimum 84 Sq In Free Air Fireplace Support m...

Страница 12: ...ely 14 3 4 to 27 1 4 Venting slots are provided at the bottom and between the fireplace and the platform 9 3 4 14 13 16 TO 27 5 16 14 13 16 27 5 16 1 Assemble Base of Platform using supplied self clinching studs nuts and screws X4 X2 Base Top OUTER SIDE PANEL OUTER SIDE PANEL INNER FRONT PANEL REAR BRACE SELF CLINCHING STUD SELF CLINCHING STUD OUTER SIDE PANEL OUTER SIDE PANEL OUTER SIDE PANEL CON...

Страница 13: ...l a layer of 5 8 drywall down to the Tile Lip This will allow for the installation of the final finishing materials down to the floor 2 Assemble Top using supplied screws 3 Set Platform at desired height and fix with screws 4 Hook back of fireplace into back of Platform and attach front with screws X10 X12 X4 5 Attach platform to floor and fireplace to framing REAR BRACE INNER SIDE PANEL INNER SID...

Страница 14: ...0 Square Inches Free Air Opening DO NOT COVER TOP OF PLATFORM WITH A SHEET OF PLYWOOD 480 Square Inches Free Air Opening TOP VIEW EXAMPLE 1 FRONT VIEW SIDE VIEW 84 Square Inches Free Air Opening 480 Sq In 84 Square Inches Free Air Opening SIDE VIEW 480 Sq In EXAMPLE 2 X 42 84 Square Inches EXAMPLE 1 1 2 X 56 84 Square Inches EXAMPLE 2 FRONT VIEW Opening must not be blocked by floor covering 14 ...

Страница 15: ...ning and fasten to framing with a wood screw at each end Then insert Grill and attach with supplied 6 black screws Do not over tighten screws USING HIDDEN GRILL MOUNT Required Opening Dimension is 48 5 8 wide x 3 5 8 tall x 2 deep Insert Upper Frame into opening and push between drywall and framing studs Attach to drywall with screws Insert Lower Frame into opening and push between drywall and fra...

Страница 16: ...and Right Side of Chase if used at Top Grills must be used on Left and Right Side of Chase if used at Bottom Pressure Fit into Framed Opening Pressure Fit into 15 1 4 Opening Fits into 6 5 8 Opening For Top of Chase Grill Openings Must be within 2 of Enclosure Top Pressure Point MQ Units FIREPLACE CHASE MUST BE VENTED AT TOP AND BOTTOM Grill openings must be within 2 of enclosure top This is to pr...

Страница 17: ...Air Opening Must be installed before front framing is in place Connect only the two center pipes when venting to an optional secondary chase vent Single Room Option Heated Room Air flows back into room with fireplace Connect all four flex pipes Ceiling Uses Kingsman VL48EG Grill Or Minimum 151 Sq In Free Air Equivalent Ceiling 2 MAX From top of Chase Optional Secondary Vent Uses Kingsman VL48EG Gr...

Страница 18: ...6cm All Vent Systems Vertical Vent Pipe in Enclosure over 76 1 2 5cm All Vent Systems MQVLBG48 SHOWN SIDE VIEW No Framing on Top Sides of fireplace for MQVL48 Single Side Units Top opening of Chase must be within 2 of Enclosure Top Min 151 sq in NOTE If using insulation in vented chase i e for outside wall wall board drywall is required to support all insulation Vented chase must be clean and free...

Страница 19: ...f the fireplace opening MQVL48 MQVLBG48 Adjacent Wall TOP VIEW Adjacent Wall may project directly from side of unit SIDE VIEW MQVLBG48 Shown Bottom Air Opening Options Min 84 sq in 1 in Min This area must be open MIN 480 Sq In 151 sq in Min 28 1 2 55 TV 3 4 15 1 4 Fireplace Opening 8 1 4 1 1 2 VARIABLE MQVLBG48 MQVL48 or MQVLBG48 with VLBGCK Corner Kit 57 1 2 Drywall 4 9 16 Opening must not be blo...

Страница 20: ...D As a Room Divider E As an Island F Right Side Corner G Exterior Wall Chase Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet 6 1 m MQVL48 Single Side Fireplace Dimensions A G C D E F 20 MAX 20 MAX B TOP FRONT BACK LEFT SIDE 20 ...

Страница 21: ... Qty 4 Nailing Tabs are located on each side of the front frame NOTE If using the rear nailing tabs for cantilevered chase etc refer to the Nailing Tab page for MQVLBG48 Bay Peninsula Pull up 90 for wall flush with fireplace face Rotate 180 for framing flush with fireplace face TOP VIEW RIGHT SIDE TOP VIEW RIGHT SIDE Flat As Shipped 18 3 8 Framing Depth 18 7 8 Framing Depth 1 2 2 1 Facing Material...

Страница 22: ...F FIREPLACE 18 7 8 Framing Flush with Face VARIABLE BACK WALL FRAMING Stud Stud 18 7 8 Framing Flush with Face Variable Can be built out to desired depth FRAMING IN FRONT OF FIREPLACE EXTENDED FRAMING IN FRONT OF FIREPLACE FRAMING IN FRONT OF FIREPLACE EXTENDED FRAMING IN FRONT OF FIREPLACE 56 1 2 Top of Platform Must Have Minimum 480 Square Inches Free Air Opening TOP VIEW DO NOT COVER TOP OF PLA...

Страница 23: ... screws into these highlighted areas Option A Open Chase at Ceiling MIN 151 Sq In Option B Vent Slot in Chase MIN 151 Sq In MAX 2 Below Ceiling Lower Vent Slot MIN 84 Sq In is REQUIRED for ALL Installations Do not drive screws into fireplace front Facing materials must be attached to framing 84 Square Inches Free Air Opening Opening must not be blocked by floor covering FRONT OF UNIT NOTE If insta...

Страница 24: ... 8 Space is required around fireplace opening Do not allow wall covering to come within this area NOTE DO NOT OVERTIGHTEN SCREWS PARTS LIST Qty 1 Surround Frame Qty 2 Black Side Fillers Qty 1 Bottom Filler Qty 1 Appliance Space Filler Qty 15 6 Black Screws TILE LIP ON FRONT OF UNIT 5 8 2nd hole from top Bottom Filler Side Filler Side Filler Surround Frame NOTE If the wall covering material is more...

Страница 25: ...EWS Set Surround to desired depth see Adjustment below ADJUSTMENT Depth of Surround can be adjusted to match thickness of wall finishing materials Gap behind Surround can be adjusted from approximately 1 2 drywall only to 2 1 4 stone brick or other materials Once depth of Surround has been set tighten screws to hold Surround in place Surround Tabs Fireplace Slots Mounting Screws Drywall 2 1 4 ADJU...

Страница 26: ...l with nails or low profile pan head screws Repeat for other side 3 Proceed with finishing wall surface Contents if Kit Qty 2 Side Extension Panels Qty 4 6 Black Screws 4 18 3 16 19 7 16 FINISHED HEIGHT FINISHED WIDTH FROM EDGE OF FIREPLACE TO OUTSIDE OF 2 X 4 18 3 16 PANEL HEIGHT 19 3 16 HORIZONTAL FRAMING DIMENSION HORIZONTAL FRAMING ABOVE TOP OF OPENING 1 2 HORIZONTAL FRAMING BELOW BOTTOM OF OP...

Страница 27: ... Remove the Side Cover Panels 4 Glass Door Front can now be lifted out of the fireplace 5 Installation is the reverse of these steps Tighten wing nuts on Glass Front until they are snug Wingnuts should be finger tight on Glass Front NOTE Do not over tighten nuts as glass could break Side Cover Panel Upper Glass Retainer X4 Ball of Gasket Faces Fireplace Use caution when working with glass Wear glo...

Страница 28: ...ight Side D Corner Kit Left Side E Corner Kit Right Side F 45 Corner G As an Island Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet 6 1 m MQVLBG48 Bay Peninsula Fireplace Dimensions A B C F 20 MAX 20 MAX G D E TOP FRONT BACK LEFT SIDE 28 ...

Страница 29: ... supporting FRAMING ON TOP OF FIREPLACE VARIABLE Can be built out to desired depth VARIABLE VARIABLE TOP VIEW BACK WALL SIDE VIEW BACK WALL 18 7 8 MIN EXTENDED FRAMING IN FRONT OF FIREPLACE TOP VIEW BACK WALL TOP VIEW BACK WALL SIDE VIEW FRAMING ON TOP OF FIREPLACE 56 1 2 WIDTH OF UNIT 18 7 8 MIN 20 3 8 MIN BACK WALL BACK WALL 18 7 8 MIN 20 3 8 MIN Sides of Unit will be exposed at viewing area Fra...

Страница 30: ...fireplace Optional framing attached to side of fireplace Optional framing attached to side of fireplace Sides of Unit will be exposed Framing depth will be increased by 1 1 2 18 7 8 MIN 20 3 8 MIN SIDE NAILING TAB MIN 84 SQ IN MIN 151 SQ IN MIN 151 SQ IN MIN 84 SQ IN MIN 151 SQ IN MIN 84 SQ IN TOP VIEW Top of Platform Must Have Minimum 480 Square Inches Free Air Opening Top of Platform Must Have M...

Страница 31: ...ws Preparation 1 Remove the Side Glass Door and frame NOTE It is not necessary to remove the Spring Mechanisms when installing a Corner Kit 2 Remove Lower Front Panel Assembly Remove Side Glass Door from firebox Refer to Side Glass Door Removal and Installation This side glass door will not be reused 3 Remove Outer Glass Supports from side of fireplace These will not be reused 4 Cut Gasket just pa...

Страница 32: ... 6 Pan Head Screws along front edge Set Stand off into position Use Qty 7 DT Screws to attach Back Top and Bottom of Heat Shield Apply Mill Pac to Gasket of Firebox Cover Slide Firebox Cover Into Place From Front IF USING PORCELAIN OR FLUTED LINERS Remove Qty 4 DT Screws from outside and install from inside firebox IF FIREPLACE IS ALREADY INSTALLED SIMPLY CUT SCREWS WITH A ROTARY TOOL Use Qty 6 Pa...

Страница 33: ...h Qty 3 DT Screws Install Side Cover Panel 1 Install Side Cover Panel when installing Glass Front Door 2 Reinstall Lower Front Panel Assembly Discard the 2 Outer Glass Supports as they are not required NOTE VLBGCK Corner Kit Requires The Same Framing And Clearances As MQVL48 60 72 Single Side 4 Install Inner Liner Panel and secure with Qty 3 DT Screws Glass Side Corner Kit side has the same Instal...

Страница 34: ...NAL COMPONENTS VALVE IPI SYSTEM Option A Open Chase at Ceiling Minimum 151 Sq Inches Option B Vent Slot in Chase MAX 2 Below Ceiling Minimum 151 Sq Inches Lower Vent Slot MIN 84 Sq In is REQUIRED for ALL Installations Do not drive screws into these highlighted areas Do not drive screws into fireplace front Facing materials must be attached to framing 84 Square Inches Free Air Minimum 34 ...

Страница 35: ...ts on Side Glass and then back them off 1 4 to 1 2 turn Finally finish tightening all wing nuts on Glass Front NOTE Do not over tighten nuts as glass could break Wingnuts should be finger tight on Glass Front To Remove Glass Front 1 Remove the Qty 4 Wing Nuts on the Upper Glass Retainer and remove the retainer 2 Loosen the Qty 4 Wing Nuts on the Lower Glass Retainer but do not remove Glass Front c...

Страница 36: ...e Bolts on the upper and lower Spring Mechanisms 2 Install Door Retainers and Wingnuts Do not fully tighten Wingnuts until Firebox Front Glass Panel is installed 3 Proceed to Front Glass Installation Instruction Glass 48VLB 311 Spring Mechanism 60VLBG 126A Replacement Part Spring Mechanism 60VLBG 126A Glass Door Frame c w Gasket SIDE GLASS DOOR Carriage Bolt Carriage Bolt SLOTS IN GLASS DOOR FRAME...

Страница 37: ...with glass Wear gloves Suction Cups Recommended Removal of the Glass Front Refer to Glass Door Front Removal Installation section of this manual 1 Remove nuts with a 3 8 wrench 2 Remove Glass Door Removal of the Glass Side Doors Refer to Glass Door Side Removal section of this manual 1 Remove nuts with a 3 8 wrench 2 Remove Glass Door Glass Replacement Safety Glass Barrier Only Tempered Low E Glas...

Страница 38: ...ULD FACE OUTSIDE REPEAT PROCEDURE FOR FRONT GLASS TWO PEOPLE AND OR SUCTION CUPS ARE RECOMMENDED 16 3 16 14 3 8 TOP SIDE GLASS PANELS QTY 2 TOP 16 3 16 54 5 8 TOP FRONT GLASS PANEL QTY 1 INSERT GLASS INTO CLIPS IN TOP OF FIREPLACE GLASS SUPPORTS PLACE GLASS INTO GLASS SUPPORTS REPEAT FOR OTHER SIDE 38 ...

Страница 39: ... Extension Harness Part No 1001 P904SI required The Remote Receiver can be mounted on a vertical wall stud using the DCHS as a mounting bracket Ensure that the face is protruding 1 2 so that the face plate will be flush on the face of the wall Drywall cutout size is 2 wide by 4 1 8 tall Must be installed within 10ft of valve assembly 6ft recommended BATTERY BACKUP REMOTE PAIRING BUTTON SW1 SWITCH ...

Страница 40: ...Canadian National Electrical Code in Canada LED Light Strip is Located Under the Firebox TEMPERED GLASS PANEL TEMPERED GLASS PANEL LED CONTROLLER MODULE LIGHT REFLECTOR BURNER PAN TOP VIEW FRONT OF FIREPLACE YELLOW CONNECTOR PROFLAME 2 MODULE GROUNDING STUD BATTERY BACKUP LED LIGHT STRIP LIGHT REFLECTOR 584 X10 HARNESS 40 ...

Страница 41: ... into SLOTS Fasten with Qty 4 DT Screws INSTALLING VL48PLE STEP FOUR Install Side Liners with Qty 3 DT Screws NOTE if you are using VLBGCK CORNER KIT only one End Panel will be used Note Warping and Discoloration of Porcelain or Painted Metal Liners Is Not Covered Under Warranty Both Porcelain and Painted Metal Liners may discolour and warp during normal operation of your appliance This is normal ...

Страница 42: ... Panel Kit CONTENTS GLASS BACK LINER X 3 BACK CLIP DISCARD MQVL48RGB BACK PANEL KIT CAUTION NOT TEMPERED GLASS EXTREMELY FRAGILE HANDLE WITH CARE STEP ONE Remove Liner Clip and screws from inside of firebox with a 1 4 hex driver Discard Back Clip but Keep Screws DT SCREW DT SCREW LOWER LINER CLIP NOT REQUIRED FOR GLASS PANELS TOP OF FIREBOX Note Discoloration of Glass Liners Is Not Covered Under W...

Страница 43: ...ND PANEL MQVL48RGE END PANEL KIT CAUTION NOT TEMPERED GLASS EXTREMELY FRAGILE HANDLE WITH CARE NOTE If using VLBGCK CORNER KIT and you are NOT installing a Glass End Panel install Inner Liner Panel from Corner Kit before Glass Back Liner However if you ARE installing a Glass End Panel do not install Inner Liner Panel from the Corner Kit PANEL SLOT FALSE BOTTOM FLANGE GLASS LIFT AND PUSH CONTINUED ...

Страница 44: ...t actions for other side NOTE if you are using VLBGCK CORNER KIT only one End Panel will be used Note Discoloration of Glass Liners Is Not Covered Under Warranty Glass Liners may discolour during normal operation of your appliance This is normal and not considered a defect LEFT SIDE END PANEL TAB FRONT OF FIREBOX 44 ...

Страница 45: ...per Liner Clips from inside of firebox with a 1 4 hex driver Reinstall Back Clip with Qty 2 DT Screws RIGHT SIDE END PANEL BACK LINER X 2 LEFT SIDE END PANEL RIGHT SIDE END PANEL MQVLBG48 WITH VLBGCK CORNER KIT SHOWN END CLIP BACK CLIP END CLIP MQVL48RLSE END LINER KIT MQVL48RLSB BACK LINER KIT BEND END CLIP INTO SHAPE REINSTALL INTO SAME HOLE IN FIREBOX Liners are Identical No Left or Right LOWER...

Страница 46: ...Drawing on Previous Page NOTE If using VLBGCK CORNER KIT remove Inner Liner Panel from Corner Kit if installed Note Discoloration of Liners Is Not Covered Under Warranty Liners may discolor during normal operation of your appliance This is normal and not considered a defect LOWER LINER CLIP X4 LOWER LINER CLIP X 4 MEDIA TRAY 46 ...

Страница 47: ... Glass Zircon Glacier Ice Use of any other glass can alter the performance of the unit and is not covered under warranty Discoloration of Glass Media may occur if placed on the burner this is not covered under warranty MQ46D Driftwood Log Set 3pcs Place Log 1 on left side of fireplace against the back wall of the firebox Place Log 2 on the right side of fireplace against the back wall of the fireb...

Страница 48: ...ed on some models MQEMBER Place these glowing ember chunks randomly Embers may be used with or without other accessories NOTE Pilot Area Must Not Be Covered as delayed ignition can occur Do Not Cover any part of the burner tube with logs as sooting may occur For best flame pattern it is essential to spread supplied Bronze Glass directly onto burner tube MQRBD1 MQRock2 Or MQRock3 48 ...

Страница 49: ...G 2 LOG 3 LOG 3 LOG 4 LOG 4 LOG 5 LOG 5 NOTE For best flame pattern it is essential to spread supplied Crushed Glass or MQEMBER directly onto burner tube If sooting occurs one or more logs may be removed LOG 1 LOG 4 LOG 2 LOG 5 LOG 3 LOG 1 LOG 3 LOG 2 LOG 5 LOG 4 Logs as Shipped Setup Option 1 Top View Setup Option 1 Front View Setup Option 2 Top View Setup Option 2 Front View 49 ...

Страница 50: ...lass MQ Rock MQ Stone or MQ Ember Follow instructions for these accessories 1 4 3 2 NOTE Pilot area must not be covered as delayed ignition could occur For best flame pattern it is essential to spread supplied Crushed Glass or MQEMBER directly onto burner tube If sooting occurs one or more logs may be moved 2 5 50 ...

Страница 51: ...y pressure testing of that system at test pressures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas sup ply piping system at test pressures equal to or less than 1 2 PSIG 3 5 KPa Gas Specifications MODELS MQVL48N NE NE2 MQVL48LP LPE LPE2 MQVLBG48N NE NE2 MQVLBGLP LPE LPE2...

Страница 52: ...w observe closely the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then continue to depress the red igniter button every 5 seconds until a flame is established NOTE If after 30 seconds a flame has not yet been established then turn the control knob back to the o...

Страница 53: ... condition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure response time of the flame safety system It must de energize the safety shutoff in no more than 30 seconds Procedure for Millivolt Units Turn on fireplace for 5 minutes Shut off fireplace while list...

Страница 54: ... Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replace faulty generator if reading is below specified minimum Plugged burner orifice Check burner orifice for stoppage and remove Defective automatic valve operator Remove wall switch wires from gas valve...

Страница 55: ...or standing pilot system even if the main burner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It is recommended to turn on the unit at least once a month and inspect the flame pattern to ensure there are no problems with the burner tube Flame should appear similar to the above picture The pi...

Страница 56: ...ting loosen screw on the side of the Air Shutter and rotate to the correct opening using a drill bit or tape measure Retighten screw 2 Remove the Main Orifice using a wrench and replace with the new Conversion Orifice which came with the Conversion Kit 3 Replace the Burner Tube Install the new Pilot Orifice See Pilot Conversion and Hi Lo valve regulator by following instructions supplied with the ...

Страница 57: ...jector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sheet for the proper injector size 6 Insert the Allen wrench into the end of the injector Then insert the injector into injector journal and rotate the injector clockwise until a torque of 9 lbf in 1 0 Nm is...

Страница 58: ...Gas Conversion for Modulator PART C 58 ...

Страница 59: ...above 2 Remove Front Reflector and Rear Reflectors 3 Remove the DT Screws around the perimeter of the burner pan 4 Carefully work the burner pan loose lift the assembly upward to remove it from the firebox cavity 5 Installation is the reverse of these steps Ensure that the mounting surface is clean and Mill Pac Black is used to reseal the burner pan Burner Tube Mount Bracket Pilot Shield False Bot...

Страница 60: ...attery Pack This component permits the IPI system to operate without the need for an external AC Adapter power source The advantage to using the battery backup is that in the case of a power failure the appliance is still operable NOTE In certain instances the IPI Main Module requires resetting This can occur if the system is unable to ignite the pilot or the main burner in the allotted time perio...

Страница 61: ...isplay on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set temperature is displayed on the LCD screen of the Transmitter Smart Thermostat Transmitter Operation The Smart Thermostat function adjusts the flame height in accordance to the difference between th...

Страница 62: ...LP 977 168 35 IPI 11 1002 P012SI IPI Stepper Kit LP 907 012 12 1002 P013SI IPI Stepper Kit NG 907 013 13 1002 P014SI IPI Reg Kit LP Hi Lo 907 014 14 1002 P016SI IPI Reg Kit NG Hi Lo 907 016 15 1002 P017SI TC Electrode Cable Sparker IPI 915 017 24 16 1002 P119SI TC Electrode Cable Sparker IPI 35 Infinite ZCVRB47 VRB46 17 1002 P903SI TC Electrode Flame Sense IPI 007 253 915 903 24 18 1002 P910SI TC ...

Страница 63: ...or units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harness as shown SCHEMATIC PICTURE NOTE Fan Option is not available on some models of fireplace Check with your dealer 63 ...

Страница 64: ...ilities Refer to the fan installation removal section for fan installation NOTE Fan Option is not available on some models of fireplace Check with your dealer NOTE This Configuration is not available on all models of fireplace Check with your dealer SCHEMATIC PICTURE 64 ...

Страница 65: ...wer Adapter P N 1002 P850si The Remote Receiver IPI or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the Remote Control Wiring Harness as per the diagrams below IPI System EGTM Millivolt System GTM Receiver Module 0 584 523 521 221 1001 P221SI Receiver Module 0 584 523 521 221 1001 P221SI 65 ...

Страница 66: ...e clockwise to off Located behind the access panel 7 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above this label If you do not smell gas go to next step 8 Turn manual shutoff valve counter clockwise to on 9 Close the glass door 10 Turn on all electric power to the fireplace and re install batteries i...

Страница 67: ...3 13 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 14 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 15 1001 P168SI TC Orifice Pilot LP 977 168 35 IPI 16 1001 P280SI TC Tubing W Fittings 1 8 2 182 280 17 1002 P012SI IPI Stepper Kit LP 907 012 18 1002 P013SI IPI Stepper Kit NG 907 013 19 1002 P014SI IPI Reg Kit LP Hi Lo 907 014 20 1002 P016SI IPI Reg Kit NG Hi Lo 907 016 21 1002 P017SI TC El...

Страница 68: ... following sequence must be followed to reset the PF2 Module Press the SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The PF2 module may now be turned on off manually x4 connector by a switch not supplied the pilot will remain on CPI continuous pilot ignition mode all other functions of main burner fan and lights will be on the high settin...

Страница 69: ... ON OFF and the pilot is also out follow the procedures described in this manual to light the pilot To switch from IPI to CPI Mode 1 Turn the fireplace OFF using the ON OFF Key 2 Press the Mode Key Display will appear as below 3 Press UP on the UP DOWN Arrow Key Display will show CPI The module in the fireplace will beep once to confirm command TO RETURN TO IPI INTERMITTENT PILOT MODE Repeat steps...

Страница 70: ...Proflame 2 Remote Control 70 ...

Страница 71: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode 71 ...

Страница 72: ...72 ...

Страница 73: ...tu h 3 kW and 50 000 Btu h 15 kW 12 in 30 cm for appliances 50 000 Btu h 15 kW K Clearance to a mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally L Clearance above paved sidewalk or paved driveway located on public property 7 ft 2 13 m 7 ft 2 13 m M Clearance under veranda porch deck or balcony 12 in 30 cm 12 in 30 cm Notes 1 In accordance with the current C...

Страница 74: ...ion Cut a hole through the wall allowing for a 12 x 12 inside diameter in combustible walls for wall thimble or a 9 diameter hole in a non combustible wall See Figure 2 2 For the clearance to combustible above a 90 degree bend see Clearance to Combustibles section 3 Select the approximate vent length precise measurements are not needed as your flex pipe can be expanded to twice its s 4 hipped leng...

Страница 75: ... system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertical runs Flex pipe runs not having 90 bends will not fall into vent table standards See Example B below Horizontal Venting Table from Bottom of Fireplace For venting to a maximum of 43ft 13 1 meters Total Verti...

Страница 76: ...e a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides and the lower edge lay on top of the shingles NOTE At the top edge of the flashing plate lift the shingles and nail the plate to the roof deck then cement the shingles to the plate with a suitable waterproof mastic Ensu...

Страница 77: ...rough roof support configuration B Flex bend configuration C Termination mounting A B C 24 Clearance to perpendicular wall 24 inches 60 cm Recommended to prevent re circulation of exhaust products For additional requirements check local codes Clearance above highest point of exit on roof 18 inches 45cm 77 ...

Страница 78: ...are permitted however Cold Climate Switch Standing Pilot Mode must NOT be used ENCLAVE SERENE Units Maximum Minimum Vent Lengths using Power Vents Minimum Vent Length is 4 FT vertical x 6 FT horizontal with up to 5 elbows Maximum Vent Length is 4FT vertical x 125FT horizontal with up to 7 elbows Refer to Power Vent Manual for proper installation and use Can Be Reduced to 4 x 6 5 8 Venting Order ZD...

Страница 79: ...5 8 Used for entire installation Order ZDVDRA ZDVDIA Z58DFA Duravent Hard Pipe Adapter 5 8 Sloped Flue Note Only sloped flues require Z58DFA adapter ZDVRA Duravent REDUCER 5 8 to 4x6 5 8 ADAPTER used at flue of fireplace Models MQVL48 60 and ZCVRB60 will require a one foot section of MG Hard Pipe at flue before using ZDVDRA ZDVDIA Termination End Duravent Pipe Increaser at Power Vent SECTION 3 FLE...

Страница 80: ... Ceramic Glass Low E Tempered Glass Safety Barrier Lights Peninsula Bay Fireplaces MQVLBG48N Peninsula Bay Fireplace Millivolt Heater rated NG Ceramic Glass Low E Tempered Safety Glass Barrier Lights MQVLBG48LP Peninsula Bay Fireplace Millivolt Heater Rated LP Ceramic Glass Low E Tempered Safety Glass Barrier Lights MQVLBG48NE Peninsula Bay Fireplace IPI Heater Rated NG Ceramic Glass Low E Tempere...

Страница 81: ...Fluted Porcelain or Reflective Glass Liners MQVL48RLFB Refractory Liner Fluted Back MQVL48RLFE Refractory Liner Fluted Ends MQVL48RLSB Refractory Liner Stacked Brick Back MQVL48RLSE Refractory Liner Stacked Brick Ends VL48PLB Porcelain Liner Back VL48PLE Porcelain Liner Ends MQVL48RGB Reflective Glass Liner Back MQVL48RGE Reflective Glass Liner Ends L R Safety Barrier Glass 48VL 315 Low E Tempered...

Страница 82: ...40099 1000 214 Piezo Igniter 1244 17 MARK 21 1000 215 Pal Nut 18MMXI 5MM BLK 1364 03 1000 218 Switch Ivory 1451 001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Brass State Size FP15GC Stainless Steel Gas Connector Kingsman Fireplace Venting Z58VT Vertical Vent Termination Z58HT Horizontal Vent Termination FDVHSCU Safety Cage for Horizontal Termination Z58AIS Attic Insulation Shield Z58AIS24 At...

Страница 83: ...chemicals other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or application of the unit or the unit s components e damages caused by failing to provide proper maintenance and service to the unit f any expenses incurred for erecting disconnecting or dismantl...