INSTALLING – Clearances
INSTALLATION
CLEARANCES (VENT
FREE APPLICATION
ONLY)
Minimum noncombustible material above
fireplace opening must be no less than
shown in the figures above.
Noncombustible materials (slate, marble,
tile, etc.) must be at least 1/2” thick, if
sheet metal is used, you must have a non-
combustible material behind it.
IMPORTANT:
If these minimum clear-
ances are not possible or if local codes do
not permit vent-free operation, you must
operate the heater with the damper open.
FIGURE 6 – Installation Clearances
FIGURE 7 – Mantel Clearances.
Minimum Fireplace Dimensions
Front width
Back Width
Height
Depth
For 18” LOGS 22" 19" 18-3/4" 12-1/2"
For 24” LOGS
29”
22 1/2”
18 3/4”
12 1/2”
For 30” LOGS
38”
28”
18 3/4”
13 1/2”
Minimum Firebox
Width
Minimum Firebox
Depth
11