Kingsman GLVF24MAN Скачать руководство пользователя страница 1

 

VENTED & VENT-FREE GAS LOG 

Owner’s Operation and Installation Manual 

 

GLVF24MAN, GLVF24MAP, GLVF24MVN, GLVF24MVP 

Vent Free:

 Certified to: ANSI Z21.11.2-2013 

Vented:

 Certified for USA and Canada: ANSI Z21.60-2012 CSA 2.26-2012 

 

 

   

 

 

 

INSTALLER: Leave this manual with the appliance. 
CONSUMER: Retain this manual for future reference. 

2340 Logan Ave., Winnipeg, MB, Canada, Phone: (204) 632-1962 Printed in Canada June 26, 2015   Part # 24GL-MAN 

This appliance must be 
installed by a licensed 
plumber or gas fitter in 
the Commonwealth of 
Massachusetts and meet 
the requirements of 527 
CMR 30 and 248 CMR. 

 

  ⚠

 -WARNING- 

FOR USE ONLY WITH 
A LISTED GAS-FIRED 

UNVENTED 

DECORATIVE ROOM 

HEATER 

NOT TO EXCEED 

40,000 BTU/H. 

DO NOT BUILD A WOOD 

FIRE. 

  ⚠

 -WARNING- 

Carefully review the instructions 

supplied with the decorative 

type unvented room heater for 

the minimum fireplace size 

requirement. 

DO NOT INSTALL AN 

APPLIANCE IN 

THIS FIREBOX UNLESS THIS 

FIREBOX 

MEETS THE MINIMUM 

DIMENSIONS REQUIRED 

FOR THE INSTALLATION. 

  ⚠

 -WARNING- 

WARNING: If the information in this manual is not followed 
exactly, a fire or explosion may result causing property 
damage, personal injury or loss of life. 

– Do not store or use gasoline or other flammable vapors and liquids in the vicinity 
of this or any other appliance. 
– WHAT TO DO IF YOU SMELL GAS 
• Do not try to light any appliance. 
• Do not touch any electrical switch; do not use any phone in your building. 
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas 
supplier’s instructions. 
• If you cannot reach your gas supplier, call the fire department. 
– Installation and service must be performed by a qualified installer, service 
agency, or the gas supplier. 

  ⚠

 -WARNING- 

Improper installation, 

adjustment, alteration, service, 

or maintenance can cause injury 

or property damage. Refer to 

this manual for correct 

installation and operational 

procedures. For assistance or 

additional information consult a 

qualified installer, service 

agency, or the gas supplier. 

  ⚠

 -WARNING- 

This Firebox is to be used only 

with certain vent-free gas log 

heaters (refer to table). Do not 

burn wood or other materials in 

this firebox. 

  ⚠

 -WARNING- 

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which 
installed. Provisions for adequate combustion and ventilation must be provided. 
See 

Safety Information & Warnings

 section. 

  ⚠

 -WARNING- 

If the information in this 
manual is not followed 
exactly, a fire or 
explosion may result 
causing property 
damage, personal injury 
or loss of life. 

Содержание GLVF24MAN

Страница 1: ...f life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any...

Страница 2: ...2...

Страница 3: ...stallations e g marble tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you burn your gas fireplace or stove for a minimum of...

Страница 4: ...VP 25 Parts List GLVF24MAN GLVF24MAP 26 Troubleshooting 27 28 Limited Lifetime Warranty 29 Gas Specifications Vent Free Vented Gas Log Sets Burner and Log Set are sold separately Burner Model Log Size...

Страница 5: ...burners and circulating air passageways of the appliance be kept clean 9 WARNING Any change to this heater or its controls can be dangerous 10 This appliance is intended for supplemental heating 11 T...

Страница 6: ...factory built fireplace or in a listed ventless firebox enclosure It has been design certified for these installations Exception DO NOT install this appliance in a factory built fireplace that includ...

Страница 7: ...de atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 per pasec m2 or less with openings gasketed or sealed and b weather stripping has been added on openable window...

Страница 8: ...outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used __________________ Btu Hr maximum the space can support __________________...

Страница 9: ...within 12 of the oor on the wall connecting the two spaces You can also remove door into adjoining room Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventila...

Страница 10: ...of the ceiling and one within 12 of the oor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces IMPORTANT Do not provide openings...

Страница 11: ...ust have a non combustible material behind it IMPORTANT If these minimum clear ances are not possible or if local codes do not permit vent free operation you must operate the heater with the damper op...

Страница 12: ...Diameter inside Area square inches 5 20 square inches 6 29 square inches 7 39 square inches 8 51 square inches WARNING Before installing in a solid fuel burning replace the chimney ue and rebox must...

Страница 13: ...joint compound check with local codes about the use of Te on tape Compounds used on threaded joints of gas piping shall be resistant to the action of Lique ed Petroleum LP or Propane and should be app...

Страница 14: ...if a leak is detected CAUTION Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the heater NOTICE A quali ed gas appliance installer must connect the re...

Страница 15: ...loose particles and dust from burner ports valve and blower compartments Vacuum any accumulation of lint from primary mixing tube Inspect ODS pilot for operation accumulation of lint at the air inlet...

Страница 16: ...ater may cause a gas leak and may result in property dam age or personal injury WARNING Failure to position the parts in accordance with the diagrams or failure to use only parts speci cally approved...

Страница 17: ...derside of Log C Place log over front burner and locator pin then lower into position as illustrated Step 3 Locate hole on the underside of Log D Place log over front burner and locator pin then lower...

Страница 18: ...Step 5 Place log A onto rear log holder and pull up to log C D LOGF18 PLACEMENT GUIDELINES continued 18...

Страница 19: ...ront main log A on log locator pins Retainer pin Step 3 Position rear main log B onto rear log holder located on rear of rebox Position locking tabs of rear main log B into locking tabs of front main...

Страница 20: ...Step 5 Place Log C onto front burner LOGF24 PLACEMENT GUIDELINES continued 20...

Страница 21: ...plate with original log locator pin 2 Slide log support over pin using two 10 24 DT screws mount plate to burner grate NOTE Make sure log support is tight against side of burner grate before fastenin...

Страница 22: ...er grate NOTE Make sure log support is tight against side of burner grate before fastening Log Locator tabs Log locator pin Rear log holder Grate Bars Step 3 Place front log by positioning the notches...

Страница 23: ...l up to the left and right front logs Step 7 Line up left crossover log with locator pins and lower into position Step 8 Line up right crossover log with locator pins and lower into position Complete...

Страница 24: ...rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then continue to depress the red igniter butt...

Страница 25: ...11 33VF P316VE 33VF P316VE Alt Tubing 3 16 12 39ZVFCV 105A 39ZVFCV 105A Burner Pan Assembly No GLVF24MVN GLVF24MVP Description 13 39ZVFCV 113 39ZVFCV 113 Valve Bracket Spacer 14 6000 112 6000 112 Valv...

Страница 26: ...39ZVFCV 115 39ZVFCV 115 Valve Bracket 11 33VF P295M 33VF P297M Regulator 12 33VF P112VE 33VF P112VE Nipple 3 8 x 1 1 2 13 33VF P124VE 33VF P124VE Street 3 8 x 45 14 1001 P100C 1001 P100C 3 8 90 FPT 15...

Страница 27: ...l or tubing Keep igniter cable dry 5 Tighten nut 6 Replace igniter cable 7 Replace piezo igniter Remedy 1 Ventilate room Stop using odor causing products while heater is running 2 Locate and correct a...

Страница 28: ...burner or replace light burner ori ce 2 Replace burner ori ce 3 Contact quali ed service person Remedy 1 Contact local gas company 2 Clean burner or replace burner ori ce Remedy 1 Clean burner or repl...

Страница 29: ...other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or app...

Отзывы: