background image

BASIC ONE YEAR WARRANTY

During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials 
or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate
schedule and any repair work must be done through an authorized Kingsman dealer.

LIMITED LIFETIME WARRANTY

The heat exchanger, combustion chamber and burner of every Kingsman product excluding the Outdoor Firepit are warranted against 
materials or workmanship during the period the product is owned by the original owner. The part to be replaced must be returned to our 
distributor in exchange for the replacement part. Any labor, material, freight and/or handling charges associated with any repair 
or replacement pursuant to this Limited Lifetime Warranty will not be covered by this warranty.

GENERAL TERMS

In lieu of providing a replacement part, we may, at our option, provide the distributor's component purchase price from us or a credit equal 
to the distributors component purchase price from us toward the purchase of any new unit which we distribute. If a credit is given 
in lieu of a replacement part, the rating plate from the unit being replaced must be submitted on a warranty claim, and the unit being
replaced must be made available to our distributor for disposition.

In establishing the date of installation for any purpose, including determination of the starting date for the term of this Limited Lifetime Warranty,
reasonable proof of the original installation date must be presented*, otherwise the effective date will be based upon the date of manufacture
plus thirty (30) days.

We will not be responsible for and you, the user, will pay for: (a) damages caused by accident, abuse, negligence, misuse, riot, fire, flood,
or Acts of God (b) damages caused by operating the unit where there is a corrosive atmosphere containing chlorine, fluorine, or any other 
damaging chemicals (other than in a normal residential environment) (c) damages caused by any unauthorized alteration or repair 
of the unit affecting its stability or performance (d) damages caused by improper matching or application of the unit or the unit's components
(e) damages caused by failing to provide proper maintenance and service to the unit (f) any expenses incurred for erecting, disconnecting 
or dismantling the unit (g) parts or supplies used in connection with service or maintenance (h) damage repairs, inoperation or inefficiency
resulting from faulty installation or application (i) electricity or fuel costs or any increase in electricity or fuel cost whatsoever including 
additional or unusual use of supplemental electric heat.

We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure of this unit. 
We have not made and do not make any representation or warranty of fitness for a particular use or purpose, and there is no implied condition
of fitness for a particular use or purpose. We make no express warranties except as stated in this Limited Lifetime Warranty. No one is authorized
to change this Limited Lifetime Warranty or to create for us any other obligation or liability in connections with this unit. Any implied 
warranties shall last for one year after the original installation. Some states and provinces do not allow the exclusion or limitation of incidental 
or consequential damages or do not allow limitations on how long an implied warranty or condition lasts, so the above limitations or exclusions
may not apply to you. The provisions of this limited warranty are in additions to and not a modification of or subtraction from any statutory
warranties and other rights and remedies provided by law.

Save this certificate. It gives you specific legal rights, and you may also have other rights which may vary from state to state and province to province.

In the event your unit needs servicing, contact your dealer or contractor who installed or serviced your unit. When requesting service, 
please have the model and serial number from each unit readily available. If your dealer needs assistance, the distributor is available for support
and we, in turn support the distributor's efforts.

Fill in the installation date and model and serial numbers of the unit in the space provided below and retain this limited warranty for your files.

Model No.

Serial No.

Date installed

Dealer or Contractor Name :

*To receive advantage of your warranty, you must retain the original records that can establish the installation date of your unit.

LIMITED LIFETIME WARRANTY

This Limited Lifetime Warranty applies only while the unit remains at the site of the original
installation and only if the unit is installed inside the continental United States, Alaska, Hawaii,
and Canada. The warranty applies only if the unit is installed and operated in accordance 
with the printed instructions and in compliance with applicable installation and building codes 
and good trade practices.

The Ultimate in Design, Engineering & Quality

Содержание FVF350

Страница 1: ...r service agency or the gas supplier Warning Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and op...

Страница 2: ...2...

Страница 3: ...wn between each Be aware during log and firebox paint curing that a white deposit may be developing on the inside of the glass doors It is important to remove this white deposit from the glass doors w...

Страница 4: ...tion 8 Ventilation Air From Inside Building 10 Ventilation Air From Outdoors 11 Installing 12 Installation Clearances 12 Installing Gas Line 14 Installing Burner Systems into Firebox 15 16 Cleaning an...

Страница 5: ...000 37 000 11 13 6 3 10 49 Full Open Fibre Log Set required for all the burners above LOGF35 Fibre Log set Door Frame required for each FVF350 Stove FVF350DG Door Frame Gold and Fixed Mesh Screen FVF3...

Страница 6: ...closed room Open the door into next room to help ventilate 8 If appliance shuts off do not relight until you provide fresh outside air If appliance keeps shutting off have it serviced 9 Do not run app...

Страница 7: ...a licensed gas tter in the Commonwealth of Massachusetts Complies to code 527CMR 28 Unvented gas red appliances may be used only for supplemental heat and or decorative purposes and under no circumsta...

Страница 8: ...atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 per pasec m2 or less with openings gasketed or sealed and b weather stripping has been added on openable windows a...

Страница 9: ...ors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used __________________ Btu Hr maximum the space can support __________________ Btu Hr...

Страница 10: ...he oor on the wall connecting the two spaces You can also remove door into adjoining room Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for requi...

Страница 11: ...12 of the ceiling and one within 12 of the oor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces IMPORTANT Do not provide openin...

Страница 12: ...should not be less than 3 inches C Clearance from the side of unit in corner 45 degree installation is 3 inches D Clearance from top of stove is 41 inches NOTICE A quali ed service person must instal...

Страница 13: ...ing Commissioner before installing this appliance otherwise your insurance company may not cover this appliance DANGER CARBON MONOXIDE POISONING MAY LEAD TO DEATH WARNING Any changes to this heater or...

Страница 14: ...burner pressure is controlled by the regulator Check pressure at the pressure test point which is located on the side of the gas control near the pilot outlet Make sure that the pressure tap is compl...

Страница 15: ...of the heater Use a soft bristle brush or a vacuum with brush attachment Vacuum loose particles and dust from burner ports valve and blower compartments Vacuum any accumulation of lint from primary mi...

Страница 16: ...to install gas line See gas line instructions NOTE For ease of installation the fan kit option if purchased should be installed now See page 20 6 Once the gas line is properly connected the control pa...

Страница 17: ...with the stove Fig 3 Log A has 2 locating holes Position the 2 holes on the log over the 2 pins on the left side of the log mounting pan as shown in the picture Fig 4 Log B has 2 locating holes Posit...

Страница 18: ...ght side panels by pulling outwards from the side of the unit 2 Slightly lift and pull door from the alignment grooves as shown in diagram 3 Hold the Door Frame in both hands and pull towards yourself...

Страница 19: ...19 MILLIVOLT LIGHTING INSTRUCTIONS CAUTION Do not wire 120 Volt power to Millivolt switches or thermostats...

Страница 20: ...panel towards you slightly and pull your right hand towards you slightly and place panel directly onto the rear of the rebox NOTE TAKE CARE NOT TO DAMAGE PILOT ASSEMBLY WHEN PLACING REAR PANEL 3 Loose...

Страница 21: ...ximately 10 to 15 minutes the fan will turn on The fan can be switched off if desired by turning the switch fully counter clockwise 6 Once the fan has started to turn it may be desirable to adjust the...

Страница 22: ...7 1000 253 Closed Nipple 8 1000 255 Orifice 9 33VF P316VE Alt Tubing 3 16 10 33VF P683VE Connector 3 16 11 33VF P245M Regulator Natural Gas Only Reference Number FVF350MVN Description 12 33VF P683VE...

Страница 23: ...e 125 x 375 6 2000 213 Elbow 3 8 7 1000 253 Closed Nipple 8 1000 255 Orifice 9 33VF P316VE Alt Tubing 3 16 10 N A Connector 3 16 11 N A Regulator Natural Gas Only Reference Number FVF350MVP Descriptio...

Страница 24: ...FF position Possible Cause Remedy 1 Gas leak 1 Locate and correct all leaks 2 Control valve defective 2 Replace control valve When igniter button is pressed there is a spark at ODS pilot but no igniti...

Страница 25: ...er is damaged 2 Replace burner 3 Gas regulator is defective 3 Replace Gas regulator Slight smoke or odor during initial operation Possible Cause Remedy 1 Vapors from paint or curing process of logs 1...

Страница 26: ...th service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoe...