TROUBLESHOOTING

NOTE: all troubleshooting items are listed in order of
operation.

When igniter button is pressed, there is no spark at ODS/Pilot.

Possible Cause

Remedy

1.

igniter electrode positioned wrong.

1.

Replace igniter.

2.

igniter electrode is broken.

2.

Replace igniter.

3.

igniter electrode not connected to igniter cable.

3.  Reconnect igniter cable.

4.

igniter cable pinched or wet.

4.

Free igniter cable if pinched by any metal or tubing.
Keep igniter cable dry.

5.

Piezo-igniter nut is loose.

5.

Tighten nut.

6.

Broken igniter cable.

6.

Replace igniter cable.

7.

Bad piezo-igniter.

7.

Replace piezo-igniter.

Appliance produces unwanted odors.

Possible Cause

Remedy

1.

Appliance burning vapors from paint, hair spray, 

1.

Ventilate room. Stop using odor-causing products

glues, etc.

while heater is running

2.

Gas leak.

2.

Locate and correct all leaks.

Appliance shuts off in use.

Possible Cause

Remedy

1.

Not enough fresh air is available for ODS/pilot  

1.

Open window and/or door ventilation.

to operate.

2.

Low line pressure.

2.

Contact local gas company.

3.

ODS/pilot is partially clogged.

3.

Clean ODS/pilot.

Gas odor even when control knob is in OFF position.

Possible Cause

Remedy

1.

Gas leak.

1.

Locate and correct all leaks.

2.

Control valve defective.

2.

Replace control valve.

When igniter button is pressed, there is a spark at ODS/pilot, 
but no ignition.

Possible Cause

Remedy

1.

Gas supply turned off or manual shutoff valve closed.

1.

Turn on gas supply or open manual shutoff valve.

2.

Control knob not in PILOT position.

2.

Turn control knob while in PILOT position.

3.

Control knob not pressed in while in PILOT position.

3.

Press control knob in while in PILOT position.

4.

Air in gas lines when installed.

4.

Continue holding down control knob. Repeat igniting
operation until air is removed.

5.

ODS/pilot is clogged.

5.

Replace ODS/pilot assembly or get it serviced.

6.

Gas regulator setting is not correct.

6.  Replace gas regulator.

ODS/pilot lights, but flame goes out when control knob is released.

Possible Cause

Remedy

1.

Control knob not fully pressed in.

1.

Press control knob in fully.

2.

Control knob not pressed in long enough.

2.

After ODS/pilot lights, keep control knob pressed in 
for 30 seconds.

3.  Manual shutoff valve not fully open.

3.

Fully open manual shutoff valve.

4.  Thermocouple connection loose at valve.

4.

Hand tighten until snug, then tighten 

1

4

turn more.

WARNING

Turn off and let cool before servicing. Only a qualified
service person should service and repair heater.

Содержание FVF350

Страница 1: ...r service agency or the gas supplier Warning Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and op...

Страница 2: ...2...

Страница 3: ...wn between each Be aware during log and firebox paint curing that a white deposit may be developing on the inside of the glass doors It is important to remove this white deposit from the glass doors w...

Страница 4: ...tion 8 Ventilation Air From Inside Building 10 Ventilation Air From Outdoors 11 Installing 12 Installation Clearances 12 Installing Gas Line 14 Installing Burner Systems into Firebox 15 16 Cleaning an...

Страница 5: ...000 37 000 11 13 6 3 10 49 Full Open Fibre Log Set required for all the burners above LOGF35 Fibre Log set Door Frame required for each FVF350 Stove FVF350DG Door Frame Gold and Fixed Mesh Screen FVF3...

Страница 6: ...closed room Open the door into next room to help ventilate 8 If appliance shuts off do not relight until you provide fresh outside air If appliance keeps shutting off have it serviced 9 Do not run app...

Страница 7: ...a licensed gas tter in the Commonwealth of Massachusetts Complies to code 527CMR 28 Unvented gas red appliances may be used only for supplemental heat and or decorative purposes and under no circumsta...

Страница 8: ...atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 per pasec m2 or less with openings gasketed or sealed and b weather stripping has been added on openable windows a...

Страница 9: ...ors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used __________________ Btu Hr maximum the space can support __________________ Btu Hr...

Страница 10: ...he oor on the wall connecting the two spaces You can also remove door into adjoining room Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for requi...

Страница 11: ...12 of the ceiling and one within 12 of the oor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces IMPORTANT Do not provide openin...

Страница 12: ...should not be less than 3 inches C Clearance from the side of unit in corner 45 degree installation is 3 inches D Clearance from top of stove is 41 inches NOTICE A quali ed service person must instal...

Страница 13: ...ing Commissioner before installing this appliance otherwise your insurance company may not cover this appliance DANGER CARBON MONOXIDE POISONING MAY LEAD TO DEATH WARNING Any changes to this heater or...

Страница 14: ...burner pressure is controlled by the regulator Check pressure at the pressure test point which is located on the side of the gas control near the pilot outlet Make sure that the pressure tap is compl...

Страница 15: ...of the heater Use a soft bristle brush or a vacuum with brush attachment Vacuum loose particles and dust from burner ports valve and blower compartments Vacuum any accumulation of lint from primary mi...

Страница 16: ...to install gas line See gas line instructions NOTE For ease of installation the fan kit option if purchased should be installed now See page 20 6 Once the gas line is properly connected the control pa...

Страница 17: ...with the stove Fig 3 Log A has 2 locating holes Position the 2 holes on the log over the 2 pins on the left side of the log mounting pan as shown in the picture Fig 4 Log B has 2 locating holes Posit...

Страница 18: ...ght side panels by pulling outwards from the side of the unit 2 Slightly lift and pull door from the alignment grooves as shown in diagram 3 Hold the Door Frame in both hands and pull towards yourself...

Страница 19: ...19 MILLIVOLT LIGHTING INSTRUCTIONS CAUTION Do not wire 120 Volt power to Millivolt switches or thermostats...

Страница 20: ...panel towards you slightly and pull your right hand towards you slightly and place panel directly onto the rear of the rebox NOTE TAKE CARE NOT TO DAMAGE PILOT ASSEMBLY WHEN PLACING REAR PANEL 3 Loose...

Страница 21: ...ximately 10 to 15 minutes the fan will turn on The fan can be switched off if desired by turning the switch fully counter clockwise 6 Once the fan has started to turn it may be desirable to adjust the...

Страница 22: ...7 1000 253 Closed Nipple 8 1000 255 Orifice 9 33VF P316VE Alt Tubing 3 16 10 33VF P683VE Connector 3 16 11 33VF P245M Regulator Natural Gas Only Reference Number FVF350MVN Description 12 33VF P683VE...

Страница 23: ...e 125 x 375 6 2000 213 Elbow 3 8 7 1000 253 Closed Nipple 8 1000 255 Orifice 9 33VF P316VE Alt Tubing 3 16 10 N A Connector 3 16 11 N A Regulator Natural Gas Only Reference Number FVF350MVP Descriptio...

Страница 24: ...FF position Possible Cause Remedy 1 Gas leak 1 Locate and correct all leaks 2 Control valve defective 2 Replace control valve When igniter button is pressed there is a spark at ODS pilot but no igniti...

Страница 25: ...er is damaged 2 Replace burner 3 Gas regulator is defective 3 Replace Gas regulator Slight smoke or odor during initial operation Possible Cause Remedy 1 Vapors from paint or curing process of logs 1...

Страница 26: ...th service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoe...

Отзывы: