background image

PARTS LIST

Part No.

Description

LOG SET: required for eack unit

LOGF5

Log Set - Four Piece Fibre Split Oak (F5000, ZDV6000, VFI30,VFI25) 

LOGC5

Log Set - Four Piece Cast Split Oak (F5000, ZDV6000, VFI30, VFI25)

ACCESSORY LIST

F35FK

Fan Kit w/Variable Speed Control (Temperature Sensing)

F5GG

Grill - Gold

F5ADDX

Arch Door Frame - Deluxe Black (352)

F5ADG

Arch Door Frame - Gold

Z1MT

Thermostat Millivolt Wall Mount

Z80PT

Thermostat Programmable Digital Millivolt Wall Mount (1F80-40)

ZIRC

Remote Control Millivolt (On/Off with LED) (Model I)

ZART

Remote Control Thermostat Millivolt (Model K)

RMCBN

Remote Control - Basic - Natural Gas (On/Off, Hi/Lo Flame Adjustment)

RMCBP

Remote Control - Basic - Liquid Propane (On/Off, Hi/Lo Flame Adjustment)

DCHS

Remote Control Heatshield

REPLACEMENT PARTS FOR FV5000

5000 - 190

Glass - Robax (13.25” x 20”)

1000 - 306

Thermalcord For Glass

5000 - 106

Top Grill

1000 - EMBERS

Glowing Embers and Slag Kit

1000 - 214

Piezo-Igniter

1000 - 216

Stove On/Off Switch

1000 - 255-35

#35 Burner Orifice NG (0 - 4500 FT)

1000 - 255-51

#51 Burner Orifice LP (0 -4500 FT)

2000 - 080

Thermostat Fan Sensor

2000 - 085

Variable Speed Switch (Fan)

3000 - 930

Thermo Disc (Spill Switch)

CONVERSION KITS (For SIT Valve only)

5000V - CKLP

LP Conversion Kit

5000V - CKNG

NG Conversion Kit

BURNER ASSEMBLY AND VALVE SYSTEM PARTS

If Serial Number is LESS than 2049:
5000 - VBNGWR

NG WHITE ROGERS BURNER ASSEMBLY C/W VALVE

1000 - P133WR

Valve NG Hi/Lo  (36D33U-100)

1000 - P134WR

Pilot Burner   

(E39A1)

1000 - P135WR

Thermocouple 

(H19E924)

1000 - P136WR

Generator

(G01A-524)

1000 - 206

Pilot Orifice

(F069-2060)

5000 - VBLPWR

LP WHITE ROGERS BURNER ASSEMBLY C/W VALVE

1000 - P101WR

Valve LP Hi/Lo  (36D33U-100)

1000 - P134WR

Pilot Burner   

(E39A1)

1000 - P135WR

Thermocouple 

(H19E924)

1000 - P136WR

Generator

(G01A-524)

1000 - 207P

Pilot Orifice

(F069-2067)

If Serial Number is BETWEEN 2050-4467 SYSTEM #1 OLD SIT SYSTEM:
5000 - VBLPSI

LP SIT BURNER ASSEMBLY C/W VALVE

5000 - VBNGSI

NG SIT BURNER ASSEMBLY C/W VALVE

1000-P136WR

Thermopile GOAI-524

1001-P035SI

Electrode Sparker 915.035 SIT

1001-P129SI

Thermocouple 290.129 SIT unified

1001-P157SI

Orifice Pilot LP 977.157 SIT

1001-P159SI

Orifice Pilot NG 977.159 SIT

1001-P508SI

HT Cable 16

1001-P633SI

Valve Nova LP Hi/Lo   0820633

1001-P634SI

Valve Nova NG Hi/Lo  0820634

1001-P605SI

Pilot Burner LP 190.605 unified SIT

1001-P606SI

Pilot Burner NG 190.606 unified SIT

15

f i r e - p a r t s . c o m

Содержание FV5000

Страница 1: ...Co Inc 2340 Logan Ave Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Read this complete manual before beginning installation These instructions must be kept with the unit for future reference FOR Y...

Страница 2: ...ever due to the high temperature silicone components the paint will cure when heat is applied to the appliance as it is first used The following information applies to the curing process to get the pa...

Страница 3: ...intenance instructions 7 General glass information 8 Log assembly 9 Log placement 10 11 Optional fan kit installation 12 Millivolt system lighting burner control 13 Vent installation 14 Accessory list...

Страница 4: ...temperatures and should be located out of heavy traffic areas and away from furniture and draperies 2 Children and adults should be alerted to the hazards of the high surface temperatures of this appl...

Страница 5: ...tockings or decorations be hung from it 9 Under no circumstances should any solid fuels wood paper be used in this appliance 10 For safe operation purge gas line with glass door removed to assure a co...

Страница 6: ...of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at test pres...

Страница 7: ...ts burners and air passages in this appliance should be kept clean and free of dust and lint Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit 7 WARNING...

Страница 8: ...reas This appliance should not be used as drying rack for clothing nor should Christmas stockings or decorations be hung near it Under no circumstances should any solid fuels wood paper cardboard coal...

Страница 9: ...imately 1 8 to all four sides of frame and insert glass with new gasket Frame should be placed on a flat surface with a small amount of weight pressing glass into sealant Let dry approximately 15 to 2...

Страница 10: ...log Step 2 Break glowing embers into thumbnail size Place glowing embers evenly on to the front burner Do not go over the grate Step 3 Place front log over front burner with the left right sides agai...

Страница 11: ...ded Bark should be to the outside Step 6 Place left crossover log into the slots that are provided Bark should be to the outside Step 7 Purge lines and test pilot operation Step 8 Replace glass door L...

Страница 12: ...to position 4 Connect the wires to the sensor and variable speed control as shown in the diagram Connect the fan extension cord to 110volt power 5 Turn the variable speed control to the on position cl...

Страница 13: ...push knob in for one 1 minute Release knob Pilot should remain lit If it goes out repeat steps 2 through 5 until pilot remains lit If knob does not pop up when released stop and immediately call your...

Страница 14: ...hes or larger Four 4 inch single wall or B Vent liquid fuel gas chimney or Flex Gas Liner may be used to adapt existing chimney or liner to stove When installing with B Vent liquid fuel gas chimney in...

Страница 15: ...r 2000 085 Variable Speed Switch Fan 3000 930 Thermo Disc Spill Switch CONVERSION KITS For SIT Valve only 5000V CKLP LP Conversion Kit 5000V CKNG NG Conversion Kit BURNER ASSEMBLY AND VALVE SYSTEM PAR...

Страница 16: ...alve Nova NG Hi Lo 0820634 1001 P713SI Pilot Burner LP 199 713 TC SIT 1001 P714SI Pilot Burner NG 199 714 TC SIT If Serial Number is GRETAER than 4740 only SYSTEM 3 New SIT TC True Millivolt Vented 50...

Страница 17: ...switch wiring for ground May be grounded to appliance or gas supply Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while hold...

Страница 18: ...ce or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoever incl...

Отзывы: