Venting Installation 

 

 

This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. 

This appliance is approved with Kingsman Flex Vent System (as listed in the manual). Do not mix venting components 
from different manufacturers. 

All venting lining products must be approved and installed according to the vent manufacturers installation instructions. All 
vent liners must terminate in a rain cap to prevent debris and rain from entering the vent and possibly damaging the 
appliance or creating an unsafe condition. The area between the existing chimney and liner must be capped off for the 
same reasons as above and to reduce the chances of venting problems and corrosion of the vent. 

If this fireplace insert is to be used to replace an existing fireplace insert the existing vent liner must be of the proper size 
and if so must be inspected for obstructions, damage and/or corrosion. Replacement must be done as necessary. 

Before any vent liner is run through a chimney or other approved venting system, chimney must be inspected, cleaned 
and repaired if necessary. A chimney which was used for a solid fuel fireplace must be professionally cleaned in order to 

reduce corrosion of the vent or other possible safety hazards. 

Installation of Vertical Termination 

1. 

Before attaching the flex vents to the termination, you will have to 

determine how the cap will be attached to the existing chimney crown, clay 
lined chimney or wood stove vent pipe. The Seal Plate of the termination 
may be cut, notched and formed to make a good seal to the existing vent 
or be left flat. 

2. 

Using a high quality sealing compound (RTV Silicone) place a bead of 

sealant onto the vent or chimney top. This will provide a seal against water 
and rain from entering the existing flue. 

3. 

Attach the vent pipes to the termination with Millpac and [4] screws and 

washers per pipe joint. Be sure to label the exhaust and intake flex pipes. 
Make sure not to connect the exhaust to the intake or vice versa. Lower the 
termination and vent pipe down the vent and screw the seal plate to the 
chimney crown, clay tile chimney, or wood stove vent. It may be necessary 
to predrill holes into the chimney crown (depending on material) [8 screws]. 

 

 

 

 

 

 

Vertical Venting in Cold Climates 

In cold climate conditions where temperatures go below -10°C [14°F], we recommend that the chase be 
insulated and where the vent pipe enters into the attic space that the pipe be wrapped with an insulated 
Mylar sleeve. This will increase the temperature of the vent and help the appliance to vent properly in cold 
weather conditions. 

It is also important in vertical vented direct vent appliances that the appliance be operated daily during the 
winter months as this will help stop the Termination from freezing up. We recommend using a thermostat 
set at room temperature to allow the unit to cycle. 

For IPI models it may be necessary to set the appliance to Standing Pilot mode to maintain heat in the 
cavity. The purpose of this procedure is to prevent cold air from penetrating the chimney and then onto the 
living space. Therefore, when the internal temperature is slightly elevated the fireplace is able to freely 
exhaust its combustion and hence making it easier to startup. 

Venting System for IDV24 

IDVVT36 

Vertical Vent Termination 

IDVFK25 

Flex Pipe kit ([Qty 2] 

3” x 25ft unexpanded 

flex pipes complete with Millpac and 
screws.) 

I23FAK-KIT 

For use with the IDV24 fireplace when 
venting must pass through a 6-inch chimney. 

 

 

Vertical (rise) 

Horizontal (run) 

Min. 

12ft [3.7m] 

0ft [0m] 

Max. 

40ft [12.2m] 

2ft [0.6m] 

 

Aluminum Flex 

 

WARNING: 

Failure to position the parts in accordance with these diagrams or failure to use only parts specifically 

approved with this appliance may result in property damage or personal injury. 

Cutting any sheet-metal parts of the fireplace, in which the gas fireplace insert is to be installed, is 

prohibited. 

PARTS LIST: 

[1] 

– Co-linear 

termination 

[8] - #8 washers 

[8] - #8 x 1 PH 

Quad 

[8] - #8-

18 x 3/4” PH 

DT 

[1] 

– Tube Millpac 

Black 

IDVVT36 

51

Содержание IDV24

Страница 1: ...d for installation in a zero clearance type listed solid fuel burning factory built fireplace It may be necessary to remove the damper plate refractory liners log grates glass door and screen rails me...

Страница 2: ...Installation of Vent Pipe section It is recommended to annually inspect and clean the Burner System to prevent malfunction and or sooting This operation should be performed by your dealer or a qualifi...

Страница 3: ...8 IDV24RLT Brick Liner Panels 19 LOGF24DW Driftwood Log Setup 20 LOGF24OAK Oak Log Setup 20 Crushed Glass and Media Options 21 MQROCK2 MQROCK3 22 MQSTONE 22 MQ EMBER Installation 23 RBCB1 Cannonballs...

Страница 4: ...Remote Control 45 Cold Climates CPI Setting 46 Proflame 2 Remote Control Operation 47 48 Proflame 2 Schematic 49 WMBH Wall Mount Battery Holder Proflame 1 and 2 IPI Models 50 Venting IDV24 Venting Ins...

Страница 5: ...move Child Safety Screens GLASS DOOR IS INSTALLED ON FIREPLACE SHOWN REMOVED FOR CLARITY ONLY HOOK SLOT HOOK SLOT To remove Safety Screens WAIT UNTIL FIREPLACE IS COMPLETELY COOL Lift up on Safety Scr...

Страница 6: ...sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can be...

Страница 7: ...due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Make sure that the ga...

Страница 8: ...ication plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to be easily read from a distance of eight f...

Страница 9: ...the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be grounded to the steel chassis of the home with 8ga copper wire using a serrated or star washer to penetrate...

Страница 10: ...IDV24 Fireplace Openings REQUIRED DIMENSION A Front Width 24 1 4 B Height 18 1 2 C Depth 14 D Back Width 19 1 4 IDV24 Fireplace Dimensions A B C D LEFT SIDE FRONT TOP 10...

Страница 11: ...round Options I24CV1BL I24CV1BL with I24S3827 Surround I24CV1BL with I24S3827 Surround I34R40 Riser I33CS Mantel Clearance Shield I24CV1BL with I24SPF3829 Picture Frame Surround I24CV1BL with I24SU454...

Страница 12: ...I24CV1BL This Surround can be custom cut and bent NOTE If you wish to make the bottom of the surround flush with the fireplace bottom cut surround at dotted line The Surround Ledge can be removed by...

Страница 13: ...nd I33CS Mantel Shield A 0 31 1 8 31 1 8 B 2 33 1 8 33 1 8 C 4 35 1 8 35 1 8 D 6 37 1 8 37 1 8 E 8 39 1 8 39 1 8 F 10 41 1 8 41 1 8 WARNING Combustible objects must not be placed on a non combustible...

Страница 14: ...sert must be pulled out so the appliance is flush with the finishing materials and the clean view kit is proud of the finished non combustible enclosure wood burning fireplace 1 2 MIN Clearance requir...

Страница 15: ...on the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury Right Side View Measure Height Le...

Страница 16: ...Clean View Surround Attachment PARTS LIST Surround Qty 9 6 Black Screws STEP 1 Place Surround against back of Clean View STEP 2 Attach Surround with 9 screws supplied with surround BACK VIEW Surround...

Страница 17: ...eside the Safety Screen Frame on the Fireplace Insert the 4 Clean View Mount Hooks into the Clean View Mount Slots and lower the Clean View into place SECTION 3 Millivolt Systems Install ON OFF Switch...

Страница 18: ...Option Place I33CS upside down on a protected surface Loosen screws Center surround onto I33CS Tighten screws to hold surround in place Surround is now ready to install onto Clean View Contents of Ki...

Страница 19: ...ips from sides of firebox 2 Install the Back Panel 3 Carefully slide and tilt Side Panels into place 4 Reinstall Brick Clips into upper sides of firebox Parts List 1 Back Panel 1 Right Side Panel 1Lef...

Страница 20: ...the left of center Place Log 6 across Log 1 and Log 2 on the left side Place Log 7 across Log 1 and Log 2 on the right side Place Embers and Insulation Wool directly onto Burner Place Lava Rock aroun...

Страница 21: ...G Decorative Glass Zircon Glacier Ice MQG5C Decorative Glass Bronze The following types of glass are approved Kingsman Decorative Glass Ember Glass Material from American Fireglass Decorative Glass Pi...

Страница 22: ...r MQ Glass can be placed on Burner and Glass Tray MQ STONE DECORATIVE STONE SET MAXIMUM 60 PIECES CAN BE USED MQ Stone can be placed on or around Burner Lava Rock is supplied with Base Unit Do not pla...

Страница 23: ...ts If sooting occurs change position of or remove affected objects MQ Glass can be placed directly on Burner and on Glass Tray Maximum 10 LBS of Glass MQ Ember can be placed directly on Burner Only La...

Страница 24: ...own 2 Carefully work the Fan Access Cover and Thermodisc Cover Millivolt Proflame 1 models loose from Mill Pac seal 3 Remove the 3 screws above the fan Twist and rotate the fan to lift it out through...

Страница 25: ...e connectors 2 12V Halogen Lights Lamp Plate 12VAC Transformer 2 Halogen Lights Lamp Lamp Top of Lamp Plate Inside Firebox Bottom of Firebox Bottom of Lamp Plate Proflame 2 Power Connection Lamp Lamp...

Страница 26: ...ews are all removed the latches will either fall or slide out 3 To remove the spring unfasten the one 1 lock nut holding it in place NOTE When replacing a spring tighten the lock nut so that the total...

Страница 27: ...rd to remove it from the firebox cavity Burner System Installation is the reverse of these steps Ensure that the mounting surface is clean Use fresh Black Mill Pac to reseal the burner pan WARNING Tur...

Страница 28: ...nding pilot system even if the main burner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It i...

Страница 29: ...ew 2 Remove the Main Orifice using a wrench and replace with the new Conversion Orifice which came with the Conversion Kit 3 Replace the Burner Tube Install the new Pilot Orifice See Pilot Conversion...

Страница 30: ...njector near the top Propane injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sh...

Страница 31: ...Gas Conversion for Modulator PART C 31...

Страница 32: ...both on the inlet and outlet of the gas valve 7 Turn the gas supply ON and check for leaks DO NOT USE OPEN FLAME FOR THIS PURPOSE Use an approved leak testing solution 8 The appliance and its individu...

Страница 33: ...ly the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then conti...

Страница 34: ...ol knob slightly and turn counter clockwise to the PILOT position 9 Push in the control knob all the way and hold it With the other hand push in the red igniter button until you hear a click Now obser...

Страница 35: ...all electric power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand 5 Wait five 5 minutes to clear out...

Страница 36: ...condition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure...

Страница 37: ...as valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replace faulty generator if reading is below specified minimum Plugged burner orifi...

Страница 38: ...power failure the appliance is still operable NOTE In certain instances the IPI Main Module requires resetting This can occur if the system is unable to ignite the pilot or the main burner in the allo...

Страница 39: ...ow the circuit is complete So the way it works is that electrical power is supplied to the Remote Receiver module and then proceeds to the Main IPI module Furthermore note that a Backup Battery Pack i...

Страница 40: ...display on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired s...

Страница 41: ...P 977 168 35 IPI 11 1002 P012SI IPI Stepper Kit LP 907 012 12 1002 P013SI IPI Stepper Kit NG 907 013 13 1002 P014SI IPI Reg Kit LP Hi Lo 907 014 14 1002 P016SI IPI Reg Kit NG Hi Lo 907 016 15 1002 P01...

Страница 42: ...s Configuration 2 Remote ON OFF and Manual HI LO Capabilities OPTIONAL For units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo...

Страница 43: ...er Adapter P N 1002 P850si The Remote Receiver IPI or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the...

Страница 44: ...13 1002 P033SI TC Pilot Burner IPI Assembled NG 199 033 14 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 15 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 16 1001 P168SI TC Orifice Pilot LP 977...

Страница 45: ...s required The following sequence must be followed to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The P...

Страница 46: ...the main burner has been cycled ON OFF and the pilot is also out follow the procedures described in this manual to light the pilot To switch from IPI to CPI Mode 1 Turn the fireplace OFF using the ON...

Страница 47: ...Proflame 2 Remote Control 47...

Страница 48: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode Halogen lights only 48...

Страница 49: ...49...

Страница 50: ...embly 12ft recommended Proflame 2 Plug the Square Plug Connector into the User Interface Socket in the P2 Module Plug the Battery Connector into Battery Holder connection on the Proflame 2 wiring harn...

Страница 51: ...to label the exhaust and intake flex pipes Make sure not to connect the exhaust to the intake or vice versa Lower the termination and vent pipe down the vent and screw the seal plate to the chimney c...

Страница 52: ...l the unit is ready to be positioned 3 Slide the unit into place carefully Ensure that the adapter slides along the top of the unit in between the guides and check that it remains flat Fig 2 4 Once th...

Страница 53: ...ill keep the chimney cavity warm and avoid cold start ignition problems FOLLOW ALL LOCAL CODES Vertical Venting Runs Taller Than 15 Feet We recommend that the pilot be left on at all times for vertica...

Страница 54: ...Inch Adapter Note The following items must be ordered separately I23FK25 Consists of 2 inch flex venting 25 foot length 3 inch flex venting 25 foot length IIDVVT36 Termination c w Seal Plate 2 to 3 I...

Страница 55: ...CSS Safety Screen Barrier Replacement BRICK LINERS IDV24RLT Brick Liners IDV24 CONVERSION KITS 24IDV CKNG Conversion Kit Natural Gas IDV24N Millivolt 24IDV CKLP Conversion Kit Liquid Propane IDV24LP M...

Страница 56: ...NG 1002 P047SI SIT IPI Pilot Assembly LP 1002 P033SI SIT IPI Pilot Assembly NG MISCELLANEOUS PARTS 1000 150 GE Silicone GE Red IS806 736 1000 150 MP Hi Temp Millpac Sealant 840099 1000 214 Piezo Ignit...

Страница 57: ...hemicals other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matchi...

Отзывы: