– Wall Coverings, Side Walls and Hearth Requirements
Refer to Mantel Heights Chart for detailed information.
Using Steel Studs and Concrete Board
Brick facing may be removed and replaced with non-combustible materials such as steel studs and concrete board. The
opening between the firebox and non-combustive materials must be sealed so as the heat cannot run between the face of
the wood fireplace and the re-facing materials.
Insert must be pulled out so the appliance is flush with the finishing materials and the clean view kit is proud of the finished
non-combustible enclosure (wood burning fireplace).
1/2” MIN
Clearance
required to
remove Clean
View
Combustible Mantel Line
SIDE WALL CLEARANCE TO
COMBUSTIBLES
TOP VIEW
Floor beneath
appliance must be
non-combustible.
Use steel studs
Use concrete board on front and
around steel stud enclosure for insert
Must be sealed to avoid heat
entering old enclosure
Existing zero clearance wood
burning / masonry fireplace
Must be sealed to avoid heat
entering old enclosure
12
” NON-
COMBUSTIBLE AREA
ABOVE FIREPLACE
14