background image

MQSW Wall Mount Surround Dimensions

Installation of MQ Wall Mount Surrounds

Remove the old CAP

(Control Access Panel), and

the Lower CVCK panel by

unscrewing the two support

screws and drilling out the

two rivets.
Remove the two upper

CVCK mounting screws

located at H2 as shown in

the figure below. IMPOR-

TANT: KEEP ALL FOUR (4)

SCREWS TO REMOUNT

THE MODERN SURROUND

ASSEMBLY.

Slightly tilt the Modern Surround assembly so that

the upper tab will clear the CVCK door opening.
Slide the Modern Surround into the CVCK and

align the holes H1 and H2. Please note that the

ledge of the Modern Surround should rest on the

CVCK Kicker Ledge.
Using the previously removed screws, secure the

upper tab of the Modern Surround in to the CVCK

frame.

Swing lower portion of the Modern Surround into the CVCK

and align the mounting holes on the Lower Tab with the

holes on the CVCK Side Frame.
Using the previously removed screws in Step 1, secure the

Lower Tab to the CVCK side frame.
Replace the old CAP with the new CAP that accompanied

the Modern Surround kit.
Check Installation to make sure the Surround and CVCK is

secure.

Concave

A

B

C

D

E

F

G

H

I

J

L

HB36

40 

1

/

2

49 

1

/

2

32 

1

/

2

21 

5

/

8

1

/

2

1

/

2

1

/

2

2

1

/

2

1

/

2

32 

7

/

16

HB42

42 

3

/

4

55 

7

/

16

36 

7

/

16

23 

3

/

4

1

/

2

1

/

2

1

/

2

2

1

/

2

1

/

2

36 

7

/

16

HB47

48 

3

/

4

61 

7

/

16

42 

7

/

16

29 

3

/

4

1

/

2

1

/

2

1

/

2

3

1 6 

1

/

2

42 

7

/

16

Convex

A

B

C

D

E

F

G

H

I

J

L

HB36

41

40 

1

/

2

32 

7

/

16

21 

5

/

8

1

/

2

1

/

2

4 1 

3

/

16

13

/

16

1

/

8

32 

7

/

16

HB42 42 

15

/

16

44 

5

/

16

36 

7

/

16

23 

3

/

4

1

/

2

1

/

2

4 1 

3

/

16

3

1

/

8

7

/

16

36 

7

/

16

HB47

48

50 

7

/

16

42 

7

/

16

29 

3

/

4

1

/

2

3

/

4

4 1 

3

/

16

3

/

4

1

/

8

42 

7

/

16

12

Содержание HBZDV4224

Страница 1: ...foot vertical off the flue before going horizontal A Division of R Co Inc 2340 Logan Avenue Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada March 31 2017 Part 42HB MAN14 INSTALLER...

Страница 2: ...sed with the installations e g marble tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you burn your gas fireplace or stove f...

Страница 3: ...LOG C44 for HBZDV4224 HBZDV4228 22 24 MQLOGC45 for HBZDV3624 3628 4224 4228 25 26 MQRSP3 with Pilot Shield 27 MQRSP3 Rock Platform Assembly 28 Pilot Shield RSP1 RSP2 29 MQROCK1 MQRSP3 for HBZDV4224 28...

Страница 4: ...until unit is COMPLETELY cool before touching glass or attempting to install or remove Child Safety Screens To install screens hook bottom clip onto glass door frame then press down and push upper cli...

Страница 5: ...ED IN MANUFACTURED MOBILE HOMES Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be grounded t...

Страница 6: ...ce 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning ma...

Страница 7: ...in the living area outside the bedroom s The carbon monoxide detector shall comply with NFPA 720 B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and sh...

Страница 8: ...on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent...

Страница 9: ...When installing horizontal with a 90 degree bend maintain a minimum of two and a half 2 5 inches above the bend in enclosures 5 For HBZDV with louvers combustible floor can raise 1 above the bot tom...

Страница 10: ...AN VIEW CIRCULATING KIT HB42CVCK WITH MQHB42SW SURROUND Note A HBCVCK must be used when installing a MQHBSW Wall Surround HB42 Framing and Facing Requirements Non Combustible Header Attached Non Combu...

Страница 11: ...ombustibles Back from Standoffs 0 inches 0 mm Side from standoffs 0 inches 0 mm Floor 0 inches 0 mm Ceiling from bottom of fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of 90 degree...

Страница 12: ...ound in to the CVCK frame Swing lower portion of the Modern Surround into the CVCK and align the mounting holes on the Lower Tab with the holes on the CVCK Side Frame Using the previously removed scre...

Страница 13: ...d on a non combustible mantel unless the non combustible mantel meets the minimum height and width requirements for a combustible mantel Caution The CVCK must be flush with the wall Note For the insta...

Страница 14: ...r over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top bo...

Страница 15: ...e variable speed wall controller to its mini mum setting fully counter clockwise Use the set screw on the side of variable speed controller to increase or decrease the mini mum fan speed lowering mini...

Страница 16: ...ck log holder on applicable units only and remove Remove screws from perimeter of burner system pan lift pan at one back corner and rotate pan up from back of firebox Make sure when tilting up and rem...

Страница 17: ...CHING THE 2 LATCH ES ON TOP OF THE UNIT 2 PLACE REAR BRICK PANEL UP AGAINST THE REAR OF THE FIRE BOX 3 LOOSEN SCREWS HOLDING BRICK CLIPS IN POSITION MOVE CLIPS UP OUT OF THE WAY AND PLACE SIDE BRICKS...

Страница 18: ...firebox by tilting top of Back Panel towards you and sliding bottom of Back Panel over burner system For HB47PL use supplied screw to attach Back Panel to firebox See Ref 2 4 Loosen screws holding Bri...

Страница 19: ...f old silicone down to metal Using a high heat silicone tempera ture resistant to 500 F 260 C apply a con tinuous bead of approximately 1 32 to all four sides of frame and insert glass with new gasket...

Страница 20: ...ront burner to the surface of the ember plates and over crossover to the same height as ember plates Height on front burner 1 2 to 3 4 Height on ember plates 3 4 to 1 Do not cover back air openings on...

Страница 21: ...ight crossover log across front and back logs using the log placement pin as a guide Step 8 Place left crossover log across front and back logs using the log placement pin as a guide Step 9 Place deco...

Страница 22: ...1 Position rear log over rear log holder and lower into position Be sure that the log does not sit on rear burner but behind and lower than burner Step 2 Locate flat surface on Log 2 and place directl...

Страница 23: ...terial from plastic bag tear off dime and nickel sized pieces and place directly onto front burner tube and crossover tube NOTE Do not place embers onto rear burner tube Step 5 Position Log 4 into gro...

Страница 24: ...Step 8 Slide Log 7 between Log 1 and Log 2 Step 9 Position Log 8 up against the 3rd grate post from the right and position upper section of Log 8 against Logs 2 and 7 Step 10 Place crushed rocks onto...

Страница 25: ...irebox Floor and against left side of Grate Bar Step 3 Rest the Small Branch end of Log 3 onto Rear Log Holder Next place Flattened area of Log 3 onto firebox floor between the right end of Grate Bar...

Страница 26: ...ace Log 6 onto Log 1 and Log 5 making sure to position between the end and center flames evenly There should be no impingement of flames or sooting may occur Step 8 Place Log 7 onto empty spot on Rear...

Страница 27: ...h Pilot Shield WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal...

Страница 28: ...to burner system without pre punched holes 1 Use the rock platform as a template for the holes to be drilled Center platform on burner system 1 from the back of firebox Ref 1 and mark the location of...

Страница 29: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 29...

Страница 30: ...t holes attach the rock platform to the burner pan as shown STEP 4 Fill around the rock platform with lava rock Sprinkle vermiculite over top of the lava rock Do not place lava rock or vermiculite on...

Страница 31: ...the burner tubes STEP 7 Place rocks 4 into position as shown STEP 8 Place rocks 6 into position as shown STEP 9 Place remaining rocks 3 and 4 into position as shown or at random Finished Rock F3 Setup...

Страница 32: ...on Log 6 along side of Log 5 and onto Log 1 as shown in the photograph STEP 6 Place the narrow end of Log 7 onto Log 4 The left front of Log 7 should touch the firebox wall or brick panel STEP 7 Place...

Страница 33: ...lways provide a union so that gas line can be easily discon nected for burner or fan servicing See gas specification for pressure details and ratings 4 When a vertical section of gas pipe is required...

Страница 34: ...above on this label If you don t smell gas then go to the next step 7 Now push in the control knob slightly and turn 4 counter clockwise to the PILOT position 8 Push in the control knob all the way a...

Страница 35: ...escription Pilot Orifice Burner Orifice Brass 1000 255 Brass Nipple Air Shutter Hi Lo Regulator 4224HB CKLP 4228HB CKLP 4232HB CKLP LP Conversion Millivolt 1001 P167SI 30 977 167 53 52 51 1000 253clos...

Страница 36: ...STEP 5 in PART B 5 Remove the 2 screws that hold the pilot to the bracket 6 Remove the 2 screws that attach the pilot bracket to the firebox bottom 7 Remove the pilot bracket to expose the pilot asse...

Страница 37: ...e new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG...

Страница 38: ...Gas Conversion for Modulator PART C WARNING WARNING 38...

Страница 39: ...the remote Contrary to this feature is a Manual HI LO Control Knob The Modulating Servo Motor requires the Remote system to be present Backup Battery Pack This component permits the IPI system to oper...

Страница 40: ...ol wiring harness instead of the main IPI harness From the Remote wiring harness use its male plug in connector and connect it to the female plug in in the main IPI harness Now the circuit is complete...

Страница 41: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 41...

Страница 42: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 42...

Страница 43: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 43...

Страница 44: ...ent LIGHTING INSTRUCTIONS 1 STOP Read the above safety information on this label 2 Remove batteries from Receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This firep...

Страница 45: ...es on venting is 1 with the following exceptions Top of horizontal 11 2 Top of 90degree elbow in enclosures under 45 to 46 is 5 Top of 90 degree elbow in an enclosure over 46 is 21 2 See pages 7 8 9 V...

Страница 46: ...ibles provided in this manual Apply a bead of Mill Pac high temp sealant to all joints of pipes adapters and termination when using Kingsman Flex Z Flex Venting venting and Simpson Duravent venting NO...

Страница 47: ...Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertical runs With use of flex pipe distance not having 90...

Страница 48: ...uitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides and the lower edge lay on top of the s...

Страница 49: ...eep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety...

Страница 50: ...IPPPED WITH INTERMITTENT PILOT IGNITION Downward vertical vent runs are permitted however Cold Climate Switch Standing Pilot Mode must not be used Refer to your appliance manual for Minimum Vertical R...

Страница 51: ...4 6 5 8 venting to 5 8 For Power Vent installations where flex pipe will be used up to the Power Vent unit Z47PVA Pipe Reducer 8 Sm 7 Sm Pipe Reducer 5 Sm 4 Sm Adapts PVH58 to accept 4 7 Flex Pipe On...

Страница 52: ...Surround Antique Brass Coverage 37 5 8 H x 45 1 8 W HB42SBL Surround Black Coverage 37 5 8 H x 45 1 8 W HB42SCR Surround Chrome Coverage 37 5 8 H x 45 1 8 W Parts List Fireplace Surrounds 4 Piece HB4...

Страница 53: ...or HBZDV4224 Millivolt 4228HB CKLP LP Conversion Kit for HBZDV4228 Millivolt 4228HB CKNG NG Conversion Kit for HBZDV4228 Millivolt 4232HB CKLP LP Conversion Kit for HBZDV4232 Millivolt 4232HB CKNG NG...

Страница 54: ...itch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connec tions are bad Generator may not be Check generator with millivolt meter Take reading at genera...

Страница 55: ...other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or app...