20lb Cylinder Installation - Fire Table -
⚠
Only a 20LB LP Cylinder may be used inside the Fire Table Enclosure.
NOTE:
Cylinders acceptable for use inside this appliance must be compatible with the retention means shown here.
•
The LP gas supply cylinder used with LP models must
be constructed and marked in accordance with the
specifications for LP-gas cylinders of the U.S.
Department of Transportation (DOT)
Specifications for
LP-Gas Cylinders, or the Standard for Cylinders,
Spheres and Tubes for Transportation of Dangerous
Goods and Commission
, CAN/CSA-B339, as applicable.
•
The LP gas supply cylinder used with LP models must
be provided with a listed overfilling prevention device.
•
The pressure regulator and hose assembly supplied with
LP models (PN#
27FP-900FF
) must be used.
Replacement pressure regulators and hose assemblies
must be those specified in this manual.
•
Always check for gas leaks with a soap and water
solution. DO NOT USE OPEN FLAME FOR LEAK
TESTING.
•
When an LP model is not in use, the LP-gas must be
turned off at the supply cylinder.
Bottom of LP
Cylinder Drops
into Round Hole
Replace
Tank Brace
.
Slide over Protective
Collar of 20lb cylinder
and tighten.
Installation of 20lb Cylinder
into Fire Tables:
•
Remove Top Clamp.
•
Connect 20lb cylinder to
regulator.
•
Place 20lb cylinder into
Fire Table as shown.
•
Secure 20lb cylinder with
Tank Brace as shown.
Tank Brace
5