SAFETY INFORMATION

SMOKE ALARM PLACEMENT

Thank you for purchasing a KingShield

Smoke Alarm from GreenBrook

Electrical. This product should be

installed by a competent person and in

accordance with the current IEE Wiring

Regulations. If in doubt, consult a

qualified electrician.

KEEP THESE

INSTRUCTIONS SAFE

FOR FUTURE REFERENCE

ALARM FEATURES

Ionization smoke alarms are generally more

effective at detecting flaming fires which

consume combustible materials

rapidly and spread quickly. Sources of these

fires may include paper burning in a waste

paper or rubbish bin or a grease fire in the

kitchen.

AC/DC operated Ionization type smoke

alarm

Ionization sensor for fast flaming fires

Low battery warning indicator

High and stable sensitivity sensor

Quick fix mounting bracket and simple

AC connector for simple installation.

Fitting and battery tamper-resist feature

Inter-connectable with up to

40

units

Self test button

Alarm and AC power-on LED indicators

Smoke alarm will automatically re-set

when smoke clears.

1

. This smoke alarm requires constant

220-240

V AC

50

Hz mains power

supply to operate properly. Backup

9

V

DC battery will offer additional protection
in the event of a power failure. DO
NOT use any other kind of battery
except as specified.

2

. The push-to-test button accurately

tests all smoke alarm functions. DO
NOT use any other test method. Test
the alarm weekly to ensure proper
operation.

3

. This alarm should be installed by

a qualified electrician in accordance
with the current wiring regulations.

4

. This alarm is designed to be used

inside a single family building only. In
multi-family buildings, each individual
living unit should have its own alarm.
DO NOT install in non-residential
buildings or places which house many
people like hotels, motels, dormitories,
hospitals, nursing homes or group
homes. This alarm is not a substitute
for a complete alarm system.

5

. Install an alarm in every room and on

every level of the home. Smoke may
not reach the smoke alarm for many
reasons. For example, if a fire starts in
a remote part of the home, on another
level, in a chimney, wall, roof or on the
other side of a closed door, smoke
may not reach the smoke alarm in
time to alert household members. A
smoke alarm will not promptly detect
a fire except in the area in which it is
installed.

6

. Smoke alarms may not alert every

household member every time. The
alarm sound of the alarm is loud in
order to alert individuals of a potential
danger. However, there may be limiting
circumstances where a household
member may not hear the alarm (i.e.
outdoor or indoor noise, sound sleepers,
the hard of hearing, etc.)

7

. Household members must hear the

alarm’s warning sound and quickly
respond to it, to reduce the risk of
damage, injury or death that may
result from a fire. If a household
member is hard of hearing, install
special smoke alarms with lights or
vibrating devices to alert occupants.

8

. Smoke alarms can only sound their

alarms when they detect smoke.
Smoke alarms detect combustion
particles in the air. They do not sense
heat, flames or gas. This smoke alarm
is designed to give audible warning of
a developing fire. However many fires
are fast-burning, explosive or intentional.
Others are caused by carelessness or
safety hazards. Smoke may not reach
the smoke alarm QUICKLY ENOUGH
to ensure safe escape.

9

. Smoke alarms have limitations. This

smoke alarm is not foolproof and is
not warranted to protect lives or
property from fire. Smoke alarms are
not suitable for insurance. Home
owners and renters should ensure
their lives and property. In addition it
is possible for the smoke alarm to fail
at any time. For this reason, you must

Minimum required smoke alarm locations

Recommended additional smoke alarm locations

Smoke alarms recommended for additional

protection

Two-Story

Residence

Single-Story Residence

test the smoke alarm weekly and re
place every

5

years.

Note:

For best protection, we recommend

that you install a smoke alarm in every
room.

Typical Single-Story Home

Install a smoke alarm on the ceiling or

wall inside each bedroom and in the hallway

outside each separate sleeping area. If a

bedroom area hallway is more than

30

feet long, install a smoke alarm at each

end. If there is a basement, install a

smoke alarm on the basement ceiling at

the bottom of the stairwell.

Typical Multi-Story or Split Level Home

Install a smoke alarm on the ceiling or

wall inside each bedroom and in the

hallway outside each separate sleeping

area. If a bedroom area hallway is more

than

30

feet long, install a smoke alarm

at each end. Also, install a smoke alarm

on the top of a first to second floor stairwell.

IMPORTANT SMOKE ALARM PLACEMENT

AND EXCEPTION INFORMATION

1

. Install a smoke alarm as close to the

center of the ceiling as possible. If this

is not practical, mount no closer than

4

inches from a wall or corner. Also, if

local codes allow, install smoke

alarms on the wall between

4

and

12

inches from the ceiling/wall

intersections.

Installation/Operating

instructions For Smoke Alarm

Model Ref: ASIM (VST-IS

598

IH)

ASIM Smoke Alarm Instructions:Layout 1  1/8/13  11:50  Page 1