background image

www.kingsbottle.com (USA) 

www.kingsbottle.com.au (Australia)

 

14

TROUBLESHOOTING GUIDE

PROBLEM

POSSIBLE CAUSE

SOLUTION

10. Water 
leakage (outside 
of the cabinet)

Condensation dripping from the glass door to the floor

Please refer to the problem #9 “Condensation on the glass door” and its 
solutions. 

Water overflows in the water pan next to the compressor

Open the back cover of the compressor and make sure that the water pipe is 
in the water receiving tray. 

11. Water 
leakage inside 
the cabinet

The outlet of the water tray below the evaporator is 
blocked

Remove the blockages

The water pipe connected to the water tray under the 
evaporator falls off.

Re-connect the water pipe, glue it with glue and tighten it with cable ties

The water tray cannot catch all the water drops from the 
evaporator

Reinstall the water tray.

12. High humidity 
in the cabinet or 
condensation on 
the bottle 
surface

Ambient humidity is high

Move the refrigerator to a cool and ventilated place

The door opening time is too long or too frequent

Reduce the times/frequency of door openings.

The door does not close properly.

Please refer to the problem #6 “The door will not close properly” and its 
solutions.

13. The 
temperature 
di

erence 

between the 
bottles inside the 
cabinet is large

There are other objects besides drink bottles in the 
cabinet, which affects the air circulation.

This refrigerator is designed for wine storage, if there are other objects, 
please remove it. The number of bottles placed on each layer cannot exceed 
the standard configuration.

The running time is too short, and the system has not 
reached a stable state.

No action required. After extending the cooling time, the temperature inside 
the cabinet will be uniform.

The upper and lower temperatures are not preset 
properly. (only applicable to dual-zone wine cabinets)

Adjust the temperature setting value; the best setting is that the preset value 
in the LOWER zone is 9°F (5°C) higher than the UPPER zone.

14. The power 
consumption is 
di

erent from the 

value on the 
label

Power consumption is related to many factors, such as 
ambient temperature, ventilation conditions, the number 
of bottles in the cabinet, preset temperature, and voltage 
level. The actual situation may differ from the power 
consumption indicated on the label. This is normal.

No action required.

15.  Incomplete 
display 
characters

The number on the display is missing one or two strokes

The wiring of the display is poor connected. In most cases, it will not affect 
the cooling function of the refrigerator.

The display is not displayed, but the keys have sound

Find a technician to repair.

16. Button failure

The door opening time is too long, resulting in too much 
condensation on the glass panel

Avoid opening the door for a long time when the machine is turned on, it will 
return to normal in ten minutes after the door is closed.

Signals such as cars, hair dryers, induction cookers, and 
mobile phones accidentally interfere with the wine cabinet

Keep away from the signal source, turn off and unplug the power, then restart 
the refrigerator.

Display or control board failure.

Find a technician to repair.

17. There is smell 
inside the 
cabinet

The new machine may leave a small amount of 
environmental cleaner

No action required, it will disappear gradually.

The smell of wooden shelves

No action required, it will disappear gradually.

18. Error code 
U1, C1, U2 or C2

Error code U1 or C1 means the sensor in the UPPER zone 
is short-circuit or open-circuit.

The sensor in the UPPER zone is defective, or the socket/plug with UP mark 
on PCB is poor connected. Please check the connection or replace the 
sensor.

Error code U2 or C2 means the sensor in the LOWER zone 
is short-circuit or open-circuit.

The sensor in the LOWER zone is defective, or the socket/plug with DOWN 
mark on PCB is poor connected. Please check the connection or replace the 
sensor.

19. Error code 
HH

High-temperature alarm

Please refer to the problem #2 “Refrigerator is not cold enough; can not cool 
down to the preset temp.” and its solutions. Then unplug the power plug for 5 
hours, restart the refrigerator.

20. Error code LL

Low-temperature alarm

1. Unplug the power for 5 hours, restart the refrigerator and check again. 
2. Check or replace the sensors and control board. 
3. Check or replace the the electromagnetic valve (applicable to KBU28LR)

PART VI

 

TROUBLESHOOTING GUIDE

Содержание KB170WX-FG

Страница 1: ...powered ON there will be a 6 minute delay for the compressor to start Note The model number in Australia is KB instead of KBU USER MANUAL KBU 50 100 170WX SINGLE ZONE WINE REFRIGERATORS BORDERLESS BL...

Страница 2: ...ers After unpacking the appliance please inspect it to verify it is not damaged If in doubt do not use the appliance but contact us or your local customer care center CONTENTS TABLE OF CONTENTS Chapte...

Страница 3: ...rapped inside s 4HIS APPLIANCE CONTAINS INSULATION FORMED WITH mAMMABLE blowing gases Avoid safety hazards by carefully disposing of this appliance WARNING The refrigerator must be plugged into its ow...

Страница 4: ...R FEATURES COMPRESSOR WINE REFRIGERATORS YOUR WINE COOLER ALSO INCLUDES THE FOLLOWING Instruction manual Two keys Top and bottom hinges also screws for changing the door hinge 1 Control board 2 Housin...

Страница 5: ...be placed in the position efficiently accommodate the door when opened and without the power cords being damaged KBU 100 23 54 598mm 26 97 685mm 55 43 1408mm 0 98 25mm KBU 170 23 54 598mm 26 97 685mm...

Страница 6: ...tension cord 8 It is recommended that you allow the unit to rest an hour or two before you put any wine bottles in it This will confirm that it is operating correctly and make the conditions appropria...

Страница 7: ...re the bracket lines up with a stud on the back of the appliance Move the appliance away from the wall and position bracket on the mark Mark and drill pilot holes into the center of the stud with a 3...

Страница 8: ...ay shelves to show your bottle label You could refer to the instruction to remove the 2nd 4th shelves at the top use the screws to fill the holes on the wall after shelves removed and then change the...

Страница 9: ...elves to show your bottle label You could refer to the instruction to remove the 2nd shelf at the top use the screws to fill the holes on the wall after shelves removed and then change the 1st 3rd she...

Страница 10: ...he ice box door opening direction 13 Reversing the door opening direction WIM1000 WFM0700 14 Reversing the door opening direction WIM1200 WRM1300 WRM2400 WFM0900 WFM1800 15 Care and maintenance Changi...

Страница 11: ...previous temperature settings will be automatically saved and each compartment will return to the previous temperature setting 2 If the unit is unplugged loses power or is turned off there will be a 6...

Страница 12: ...tor is placed outdoors or in a place with a lot of dust oil stains after a period of time a large amount of dust will accumulate on the condenser fins which will affect the cooling effect Move the ref...

Страница 13: ...oling performance The fridge does not cool or can not reach the preset temperature value Please refer to the problem 2 Refrigerator is not cold enough can not cool down to the preset temp and the corr...

Страница 14: ...ambient temperature ventilation conditions the number of bottles in the cabinet preset temperature and voltage level The actual situation may differ from the power consumption indicated on the label...

Страница 15: ...er reference The symbols you will see in this booklet have these meanings WARNING 6FGQ QWK MJ GLBGA RCQ GLDMPK RGML AMLACPLGLE WMSP NCPQML J Q DCRW CAUTION 6FGQ QWK MJ GLBGA RCQ GLDMPK RGML ML FMU RM...

Страница 16: ...gerator is not operating properly KingsBottle reserves the right to repair or replace the refrigerator KingsBottle may request the consumer to contact a local refrigeration company to service the refr...

Отзывы: