Kingray KLA-110 Скачать руководство пользователя страница 10

PA G E   1 0  

P R O G R A M M I N G   M A N UA L  

K L A - 1 1 0

4.1  SAVE SETTINGS

The system will allow you to save the parameters of the system. 
This is particularly useful to clone a system when installing several 
headends that are the same or just for record keeping. 
To save the settings, in system configuration menu, click on ‘save 
settings’ and the following window will appear. Click on ‘Save’.

The following window will now appear. Find a Directory you wish 
to save the file to and type in the name you wish to call the file. 
Then click ‘save’. The parameters will now be saved.

4.2  RESTORE SETTINGS

When cloning or uploading previously saved settings, in ‘system 
configuration’ menu, click on ‘Restore settings’ and the following 
window will appear. Click on ‘Browse’ to locate the saved file. 
Click ‘Upload’. This will now upload the saved settings.

NOTE: 

When cloning a system, make sure the modules installed are 

exactly the same configuration of the previous saved otherwise a 
successful restore will not occur.

4.3 IDENTIFICATION

Identification allows the installer to put his or her details in the 
system. This is ideal for information on who installed the system 
or worked on the system last. This may also be useful for error 
reporting.
To check or edit the identification settings, in system configuration 
menu, click on ‘Identification’ and the following window 
will appear. 

To add or edit the text, click on ‘Edit’. A new window will appear.

Information can now be entered. Once complete, click ‘Write’. This 
will save your information to memory.

Содержание KLA-110

Страница 1: ...PAGE 1 PROGRAMMING MANUAL KLA 110 PROGRAMMING MANUAL KLA 110 Launch Amplifier Power Supply...

Страница 2: ...and Mozilla Firefox 3 6 For the latest version of software please visit our website www kingray net au for download 1 1 GETTING STARTED Now that you have installed the rack launch amplifier and module...

Страница 3: ...clip to activate the reset for 3 seconds on the front of the KLA 110 as shown in the adjacent image This will reset the username and password back to default No other settings will be affected Once th...

Страница 4: ...Repeat these steps until all modules are in their correct physical position The system displayed on your computer will replicate the number position and type of modules installed To change other setti...

Страница 5: ...changes have been made click Write and the new settings will be saved in memory 2 3 KLA 110 PARAMETERS In the KLA 110 settings you can change the Module Name the Output Level via the gain and switch...

Страница 6: ...ware across to your C drive on the computer being used to program the module 2 Double click on the file TS0102 msi You will see the following window s appear Follow the steps through the installation...

Страница 7: ...e directory Windows_2K_ XP_S2K3_Vista 10 Now double click on the file CP210xVCPInstaller exe to install the software 11 The following window will now appear Choose your location and click Install 12 O...

Страница 8: ...applicable to your country e g 7 MHz for Australia 8 MHz for other countries RF in MHz Enter in the frequency of the incoming channel RF out MHz Enter in the frequency of the outgoing channel Output L...

Страница 9: ...r for desired output level Temperature Sensor Temperature of power supply Output Level Output level set by Gain max 10 channels at 110 dBuV 60 dB IMR External Power ON OFF Allows 18 volts 100mA to be...

Страница 10: ...u click on Restore settings and the following window will appear Click on Browse to locate the saved file Click Upload This will now upload the saved settings NOTE When cloning a system make sure the...

Страница 11: ...ettings so you are able to access the system again at a later stage 4 5 PASSWORD For increased security protection the password can be changed rather than using the default password admin To change th...

Страница 12: ...the software but it doesn t communicate with the module Solution Check that your USB port in the computer is the same as what the software is Check you communication ports in Device Manager and check...

Страница 13: ...dress automatically then you won t be able to connect directly to the Kingray Professional Series You must make sure you have a static IP address set up as below to connect to the system Under the Gen...

Страница 14: ...ING WINDOWS 7 Go to START then click on CONTROL PANEL Click on NETWORK AND SHARING CENTER In the left hand column click on CHANGE ADAPTER SETTINGS Double click the icon LOCAL AREA CONNECTION Click on...

Страница 15: ...essional Series You must make sure you have a static IP address set up as below to connect to the system Under the General tab enter in the following IP settings other IP addresses can be used providi...

Страница 16: ...n Hills NSW 2153 T 02 8867 6000 F 02 8867 6199 Enquiries tech support 1300 463 463 Sydney Melbourne Brisbane Adelaide Perth Auckland 02 8867 6000 03 9558 9999 07 3278 6444 08 8234 2633 08 9455 5744 09...

Отзывы: