3.11 Precautions for the Lift Pipe
The installation height of the lift pipe should be less than 850mm. It is recommended to set an
inclination angle 1°
~
2° for the lift pipe toward the drainage direction. If the lift pipe and the unit
form a right angle, the height of the lift pipe must be less than 800mm.
1°
~
2°
1~1.5m
≤
1000mm
≤
850mm
≤
300mm
150mm
①
②
Ceiling
Clamp (accessory)
Drain Hose (accessory)
Lift Pipe
Hanger Bracket
Fig.16
Notes:
① .
The inclination height of the drain hose should be within 75mm so that the outlet of the
drain hose does not suffer the external force.
② .
If multiple drain pipes converge, please follow the installation steps below.
I
- Joint of drain pipe
The specification of the joint of the drain pipe should be suitable to the running capacity of the unit
Drain Hose (accessory)
Max.75mm
Max.1000mm
Fig.17
3.12 Test for the Drainage System
(1). After the electric installation, please take a test for the drainage system.
(2). During the test, check if the water flow goes through the pipe correctly and observe