Revision: 4                                 Date: 18 Jun 2020                                                                    Page 7 of 28 

5.  Instrument Layout 

 

 

 

 

 

 

 

 

 

Instrument keys 

Optical Connector 

Charging status 

LED 

Mini-USB 

connector 

Color LCD Display 

Содержание KI6501

Страница 1: ...pair of the equipment This Kingfisher International product is guaranteed against defective components and workmanship for a period of 1 year from the date of delivery unless specifically stated in th...

Страница 2: ...tions of instrument keys 8 6 2 Switching Instrument ON OFF 9 6 3 PM Power Meter Mode 10 6 4 CWDM Mode 12 6 5 SCAN Mode 12 6 6 Measurement unit dB dBm selection 13 6 7 Graphical Display Mode 14 6 8 Sav...

Страница 3: ...nagement Software enables stored test data to be downloaded to PC Applications of KI6501 CWDM Power Meter include the following Wavelength selective Power Meter for systems with CWDM channel spacing Q...

Страница 4: ...librated wavelengths Larger sunlight readable backlit colour display Simultaneous 9 wavelengths loss display Tabular and graphical display modes Internal memory for 1000 test records Test data transfe...

Страница 5: ...Display 2 8 Colour LCD with backlight Display unit dBm dB Display resolution 0 01 dB Memory 1000 records of 18 tests in internal memory PC interface Data transfer via USB Battery type Built in rechar...

Страница 6: ...isture gets into the instrument remove the batteries and dry it out carefully for at least one hour before using it again Storage The equipment can be stored at the specified temperatures and relative...

Страница 7: ...Revision 4 Date 18 Jun 2020 Page 7 of 28 5 Instrument Layout Instrument keys Optical Connector Charging status LED Mini USB connector Color LCD Display...

Страница 8: ...er Meter Mode CWDM Scan present dBm in single wavelength display mode SCAN Scan present dBm in multiple wavelength display mode dB dBm Toggle between measurement units Graph Present scanned dBm wavele...

Страница 9: ...n see pictures below for instrument displays When the instrument is switched ON its LCD backlight can be toggled ON or OFF by pressing Backlight Backlight will turn off automatically approx 30 seconds...

Страница 10: ...is operation mode the instrument automatically scans the optical input and displays the wavelength along with its corresponding measured power value which has been detected with the highest level of p...

Страница 11: ...e power values of the wavelengths available at the optical input See picture below for user interface of this mode In PM auto Mode press PM once to switch to PM Manual Mode Use to select the desired w...

Страница 12: ...Use to display the power values of other wavelengths scanned at the optical input 6 5 SCAN Mode When SCAN is pressed the wavelengths and their corresponding power values scanned at the optical input w...

Страница 13: ...Page 13 of 28 6 6 Measurement unit dB dBm selection Press dB dBm to toggle between the measurements units of dB and dBm in PM Power Meter Modes The displayed power will be become 0 00 dB when dB dBm...

Страница 14: ...le Press Graph again will switch the display to the multiple wavelength format shown in example of section 6 5 6 8 Saving Scanned Data in Instrument s Memory In SCAN Mode press Save to save the scanne...

Страница 15: ...ieving Data Save in Instrument Press Recall and the user interface below will be displayed Use to highlight the desired file in which data was saved followed by pressing ENTER The data will be retriev...

Страница 16: ...retrieved data in graphical or tabular multiple wavelength format 6 10 Instrument Setup options Press Menu to display the available instrument setup options in the Menu Option List Pictures below show...

Страница 17: ...strument scans its optical input for all 18 wavelengths despite of the wavelengths selected in Select Lambda option see section 6 10 2 When All Scan is OFF Selected is ON The instrument scans its opti...

Страница 18: ...o select the wavelength s press ENTER on the display below Use to highlight the desired wavelengths from the available 18 wavelengths displayed in 2 pages Press ENTER to toggle ON select or OFF unsele...

Страница 19: ...offset by the value pre programmed in this option See picture below for this option s user interface Press ENTER use the numerical keys to input the desired offset values between 25 99 25 99 dBm Use o...

Страница 20: ...elapsed before the instrument is automatically switched off after the last key press See picture below for this option s user interface Press ENTER use numerical keys to input a time between 5 600 min...

Страница 21: ...o Menu Option list without saving 6 10 5 Data Delete option Use this option to delete selected test data records from instrument s internal memory See picture below for this option s user interface Us...

Страница 22: ...o delete all test record files saved in instrument s internal memory See picture below for user interface of this option Press ENTER to confirm that All data will be deleted or press ESC to return to...

Страница 23: ...y work only with Scan Mode section 6 5 optical input scan result in the following options Display the scanned wavelengths detected with power values only OR Display all the wavelengths selected for sc...

Страница 24: ...ode option This option provides an alternative method to that in section 6 3 of programming PM Modes see section 6 4 to operate in Auto or Manual condition See picture below for the user interface Use...

Страница 25: ...hreshold level which is visible when the scanned data is presented on graphical format Use the numerical keys to enter a new valid threshold value 40dBm 10 dBm and use for or sign selection Press ENTE...

Страница 26: ...26 of 28 6 10 11 Graph Color This option provides choices of displaying graphical test result in different colour format Previously programmed threshold Reprogrammed threshold Previously programmed t...

Страница 27: ...ng of Instrument Link the mini USB connector on instrument see section 5 Instrument Layout to a PC s USB port or a USB charger using the provided USB cable The Charging Status LED see section 5 Instru...

Страница 28: ...free of dust or other contaminant by cleaning them regularly 2 Do not use unclean or nonstandard adapters 3 Change adapter carefully if necessary and keep any spare adapter in dirt dust free environme...

Отзывы: