3.6 Alert/Pass/Fail threshold setup 

 

Choose a threshold group number from the available 01, 02, 03 using [▲, 

▼].     

 

 Use [◄, ►] to select wavelength from the available 1270, 1310, 1490, 

1577 nm.                                                                        

 

 P

ress and hold [OK] to enter editing mode.  

Use [◄, ►] to move cursor and highlight the digit on display to be edited.  

Use [▲, ▼] to change value of selected digit. 

Use [▼] to change the sign (positive or negative) of the value.  

 

 After all the 3 threshold values (see below) for the selected wavelength 

are correctly set, 

Alert (displayed as 

!

Pass (displayed as 

√ 

Fail (displayed as x

 

)  

The  alert/pass/fail  threshold  values  for  1270, 
1310, 1490, 1577 nm can be individually preset. 
These preset values can be stored in 3 groups 
(01, 02, 03). 

 

To enter Threshold Setup mode (see picture on 
the right), press and  hold [▲] at  home display. 
Note that this mode will exit automatically if no 
subsequent  key  is  pressed  10  sec  after  being 
selected. 

 

To preset and save threshold values, see steps 

 ~ 

 below. 

 

 

Threshold group number

 

Содержание KI6106 Series

Страница 1: ...ed repair of the equipment This Kingfisher International product is guaranteed against defective components and workmanship for a period of 1 year from the date of delivery unless specifically stated...

Страница 2: ...ON OFF instrument 5 3 2 Auto Power Off mode 5 3 3 Setting Time 5 3 4 Selecting measurement unit 6 3 5 Relative Measurement Mode 6 3 6 Alert Pass Fail threshold setup 7 3 7 Measurement with Pass fail D...

Страница 3: ...2 1 The instrument Rubber holster Captive dust cap Battery door Product label LCD Keypads Charging jack USB connector Rubber flap Optical connector ports ONT left for upstream 1270 1310 nm tests OLT r...

Страница 4: ...40 40 Uncertainty dB 0 5 Polarization Dependent Loss dB 0 25 Linearity dB 0 1 Insertion Loss dB 1 5 Resolution 0 01dB Measurement unit dBm dB W Pass Fail Memory capacity 99 records of 4 with date time...

Страница 5: ...Off mode is enabled instrument will switch off automatically if no subsequent key is pressed 10 minutes after it was switched on To disable enable Auto Power Off mode press OFF in turn 3 3 Setting Ti...

Страница 6: ...and time format Date YY MM DD Time HH MM Time Setting mode will exit automatically if no subsequent key is pressed 10 sec after it was selected 3 4 Selecting measurement unit At home display press F2...

Страница 7: ...ve or negative of the value After all the 3 threshold values see below for the selected wavelength are correctly set Alert displayed as Pass displayed as Fail displayed as x The alert pass fail thresh...

Страница 8: ...urn to home display 3 7 Measurement with Pass fail Display Mode When performing measurements in this mode measurement results based on the threshold values set in section 3 6 for each wavelength will...

Страница 9: ...the above Data Saving mode will exit automatically if no subsequent key is pressed 10 sec after being selected To retrieve saved measurement data Press and hold to enter Data Browsing mode indicate by...

Страница 10: ...rged Standard instrument comes with a charger of US type AC plug If require order suitable AC plug adapter from Optional Accessories section below 4 Maintenance Keep the sensors surfaces clean and fre...

Страница 11: ...emove the batteries and dry it out carefully for at least one hour before using it again Storage During prolonged storage remove batteries to eliminate the possibility of acid leakage Use only high qu...

Страница 12: ...Revision 2 Date 11 Jun 2020 Page 12 of 12 7 Optional Accessories Description P N AC Power Adapter Plug US to UK OPT093 AC Power Adapter Plug US to AUS OPT094 AC Power Adapter Plug US to EUR OPT095...

Отзывы: