SELECTION:

 

MODEL

 

KBP1230

 

KBP2406

 

KBP2006-3MP**

 

KBP2406-3MP**

 

KBP2704

 

KBP4804-3MP**

 

KBP4806-3MP**

 

    UPC

 

#093319

 

PART #

 

15191

 

15190

 

15193

 

15188

 

15187

 

15196

 

15197

 

VOLTS

 

120

 

240*

 

208

 

240*

 

277

 

480***

 

480***

 

PHASE

 

1

 

1

 

1-3

 

1-3

 

1

 

1-3

 

1-3

 

WATTAGE RANGE

 

2850 • 1900• 950

 

5700 • 4750 • 3800

 

 

2850 • 1900 • 950

 

5700 • 2850

 

5700 •2850

 

4000 • 3000

 

2000 • 1000

 

4160

 

6000

 

PHASE AMPS

 

    SINGLE /

 

      THREE

 

24

 

24

 

27 / 16

 

24 / 14

 

15

 

9/5

 

13 / 8

 

380V-3Ø Heaters are available in most kW ratings

 

MOTOR

 

  SIZE

 

5W

 

5W

 

5W

 

5W

 

5W

 

5W

 

5W

 

CFM

 

270

 

270

 

270

 

270

 

270

 

270

 

270

 

TEMP RISE

 

      (°F)

 

35°

 

70°

 

70°

 

70°

 

47°

 

49°

 

71°

 

AIR ThROW

 

16 ft.

 

16 ft.

 

16 ft.

 

16 ft.

 

16 ft.

 

16 ft.

 

16 ft.

 

  WT.

 

(lbs.)

 

26

 

24

 

26

 

25

 

26

 

26

 

26

 

* Approved for 208V operation. Heater will draw 13% less Amps and 25% less wattage

 

** 3-Phase units do not have Heat / Fan / Off

 

*** 480 Volt models are 24 Volt control

 

ACCESSORIES

:

 

MODEL

 

KBP-K1

 

KBP-K2

 

KBP-RT

 

*KBP-RTLV1

 

*KBP-RTLV3

 

DESCRIPTION

 

6 ft. Cord / Handle Kit - 120 V, 1-Phase, 30 Amp

 

                              (receptacle included)

 

6 ft. Cord / Handle Kit - 240 V, 1-Phase, 30 Amp

 

                              (receptacle included)

 

Provision for Remote Thermostat (line voltage)

 

Provision for Remote Thermostat 

– 1-Phase

 

                                    (24V)

 

Provision for Remote Thermostat 

– 3-Phase

 

                                    (24V)

 

  UPC

 

#093319

 

PART #

 

15198

 

15199

 

N/A

 

N/A

 

N/A

 

  WT.

 

(lbs.)

 

2

 

2

 

N/A

 

N/A

 

N/A

 

MODEL CODE

:

 

KBP2006-3MP-RT-RTLV

 

KBP

 

208

 

5700

 

3MP

 

RT

 

RTLV

 

Series

 

Volts

 

Watts

 

1 or 3

 

Phase

 

Remote

 

  T-Stat

 

24V Remote

 

          T-Stat

 

* Factory installed only - Heat / Fan / Off activated at unit only - can not

 

operate remotely

 

Standard Color: Textured Almond

 

Receptacle configurations included for cord set

 

30 Amp

 

120 Volt

 

N.E.M.A. #5-30P

 

Model KBP-K1

 

30 Amp

 

250 Volt

 

N.E.M.A. #6-30P

 

Model KBP-K2

 

INSTALLATION WIRING FOR REMOTE THERMOSTAT 

 

      Power must be routed to heater first, then to remote

 

      thermostat. This is due to the fan delay circuit needed

 

      to cool the elements on shutdown.

 

DIMENSIONS:

 

FRONT

 

13½" H x 10" W x 11½" D

 

BACK

 

                                  2 MOUNTING STYLES

 

Multi-positional bracket allows unlimited mounting options

 

1 11/16"

 

1 13/16"

 

Bracket side and bottom view

 

KING ELECTRICAL MFG. CO.

 

      2 5/16"

 

¾" knockout

 

 

2 ⅜"

 

½" knockout

 

69

 

Содержание KBP series

Страница 1: ...disconnects all ungrounded conductors Not available in 480V and 3 Phase models Tested under UL1278 for a garage or shop heater with the capacity to easily heat a large space The flow through design moves air efficiently by pulling air from the back of the heater and discharging it out the front This rugged heater has quality components suitable for commercial applications as well It comes standard...

Страница 2: ...20 V 1 Phase 30 Amp receptacle included 6 ft Cord Handle Kit 240 V 1 Phase 30 Amp receptacle included Provision for Remote Thermostat line voltage Provision for Remote Thermostat 1 Phase 24V Provision for Remote Thermostat 3 Phase 24V UPC 093319 PART 15198 15199 N A N A N A WT lbs 2 2 N A N A N A MODEL CODE KBP2006 3MP RT RTLV KBP 208 5700 3MP RT RTLV Series Volts Watts 1 or 3 Phase Remote T Stat ...

Страница 3: ... You will need the following tools to install your unit heater Screwdriver Phillips Slotted Wire Cutters Pliers Adjustable Wrench Electric Drill Location of Heater The heater should be installed out of reach of persons The direction of airflow should not be restricted by machinery beams etc and the airflow should wipe exposed walls rather than blowing directly at them When more than one heater is us...

Страница 4: ...ory wired for maximum wattage of 5700 Watts at 240 Volts To reduce the wattage unplug disconnect an insulated push on terminal and wrap with electrical tape to prevent the possibility of electrical contact with other parts BLACK 14 ORANGE RED BLUE A 950 WATT F E 950 WATT B 950 WATT BLACK 14 E Insulated Push on Terminal YELLOW C Field Wattage Selection 1 5700 Watts factory wired 2 4750 Watts discon...

Страница 5: ...use with Cat No LPW wall can Fixed Wall insert type Models d W1205 07 10 12 15 W2405 07 10 12 15 20 24 for use with Cat No W Fixed Wall surface mounted type Models e KCV 1202 2402 1204 2404 1206 2406 1207 2407 1209 2409 1210 2410 2412 1215 2415 1218 2418 Fixed Kick space type Models f KT1205 KT1207 KT2405 KT2407 KT2410 with or without suffix numerals 10 15 or 20 KT10 KT15 KT20 with or without pref...

Страница 6: ... subject to the following conditions 1 The Guide Information Designs and or Listings files must be presented in their entirety and in a non misleading manner without any manipulation of the data or drawings 2 The statement Reprinted from the Online Certifications Directory with permission from UL must appear adjacent to the extracted material In addition the reprinted material must include a copyr...

Страница 7: ...ook for the Mark on the product UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions 1 The Guide Information Designs and or Listings files must be presented in their entirety and in a non misleading manner without any manipulation of the data or drawings 2 The statement Reprinted from the Online Certifications Directory wit...

Отзывы: