15
(6) Operating Procedures
Ultrasonic Welding Steps
1. Select vibration amplitude, level
2. Adjust the frequency
3. Align
the
welding
head, work-piece, and
base contact surface
1. Set the welding pressure
2. Set the rise and drop speed of the stroke
3. Set the delay-on time
4. Set the height adjustment screws
1. Set the welding time
2. Set the curing time
Trial run
Check the amplitude gauge
Overload
Display the amplitude with load
1. Decrease
the
pressure
2. Reduce the drop speed
3. Reduce
the
delay-on
time
4. Reduce the level of
amplitude
5. Replace with a model
with higher power
Check the product
Bad Good
Bad Welding
1. Increase the welding time or
pressure
2. Increase the level of amplitude
3. Replace with a model with
higher power
Over welding
1. Reduce the welding time
and pressure
2. Reduce the level of
amplitude
Data Record
Level, pressure, delay-on, welding,
curing time