background image

1

Customer Service 800-222-0169

www.kingtechnology.com

FROG Leap

 

Infuzer

 

Mineral Dispensing System

Model 7800 

For Pools up to 25,000 Gallons

System Includes the 

FROG Leap Anti-Bac Mineral Pac

Patented Mineral Disinfectant

infuzer

Содержание Frog Leap Infuzer 7800

Страница 1: ...rvice 800 222 0169 www kingtechnology com FROG LeapInfuzer Mineral Dispensing System Model 7800 For Pools up to 25 000 Gallons System Includes the FROG Leap Anti Bac Mineral Pac Patented Mineral Disinfectant infuzer ...

Страница 2: ...h Charge Reveille Torpedo Pac 8 Using FROG Leap ALL OUT 9 Troubleshooting 10 Parts List 11 Replacing Control Dial O Rings 12 Replacing Cap O Rings and Knobs 12 Winterizing 13 Above Ground Filter Installation 14 Above Ground Base Installation 15 Warranty 16 For information on King Technology s entire product line visit our website at www kingtechnology com ...

Страница 3: ...ol opening program that effectively removes contaminants prevents algae and sets a chorine residual with precise dispensing and no touching chemicals FROG Leap Pool Hibernation An easy 2 step pool closing program that effectively removes contaminants and prevents algae all winter with precise dispensing and no touching chemicals Part 4 FROG Leap Torpedo Pac Pre filled with chlorine tablets and fit...

Страница 4: ...nt or metal out product at start up only before using the FROG Leap Anti Bac Mineral Pac See your local dealer for details on using these products and always follow manufacturers directions carefully 4 After your pool is up and running smoothly continue to test your water for pH total alkalinity and chlorine with FROG Brand Test Strips and maintain its balance by adding any necessary adjustment pr...

Страница 5: ...SEASON WHICHEVER IS SHORTER Replace cap and run FROG Leap Infuzer with FROG Leap Anti Bac Mineral Pac inserted for 10 minutes at Setting 5 When chlorine reading is down to 1 0 ppm which may take a few days insert FROG Leap Torpedo Pac See page 8 for directions Create a chlorine residual with FROG Leap Reveille or a chlorine shock see page 8 for FROG Leap Reveille directions THIS STEP IS VERY IMPOR...

Страница 6: ...nd your starting dial setting by matching up the parameters of your pool on the above chart An above ground pool with approximately 12 000 gallons with a 1 horse pump running 12 hours a day would require a starting setting of 4 5 See example at right Bypass installation recommended RECOMMENDED FLOW RATE 20 60 gpm NR This pump size is not recommended for this size pool Most common pool sizes 9 Do n...

Страница 7: ...r product could result in damage to pool equip ment or surface unsafe pool conditions fire or explosion Warranty will be VOID if the correct FROG Leap products are not used 2 3 Turn off pump and turn dial to Setting 0 This reduces the flow of water into the unit when the cap is open 4 Open cap Stand back to avoid inhaling chlorine fumes from the FROG Leap Torpedo Pac 5 Find slot on side of FROG Le...

Страница 8: ...l setting for maintaining up to 50 less chlorine while using the FROG Leap Torpedo Pacs EPA Reg No 53735 2 All three products sold separately Replacing FROG Leap Depth Charge FROG Leap Reveille or FROG Leap Torpedo Pac OTHER PAC FROG LEAP ANTI BAC MINERAL PAC PAC TOWERS PAC TOWERS COLORED CAPS Turn pac over and shake slightly until ingredients fall into tower areas To remove colored caps grab onto...

Страница 9: ...nter of FROG Leap Anti Bac Mineral Pac pushing down firmly on key to puncture seal Replace cap by hand only DO NOT OVER TIGHTEN Turn control dial on FROG Leap Infuzer to Setting 5 2 3 4 5 Turn pump on for 90 minutes allowing FROG Leap ALL OUT to circulate through pool 6 To remove FROG Leap ALL OUT turn pump off Turn dial to Setting 0 7 Remove FROG Leap Infuzer cap 8 Lift FROG Leap ALL OUT up and a...

Страница 10: ...n one day 4 Make sure pump run time is at least 6 hours on high speed 40 gpm or higher or if not bleed the air from the back knob each time cap is open 5 Contact your dealer to have your back pressure tested to ensure it is at least 4 psi 6 Check for a suction side leak by looking for air bubbles in your pump basket or at the return jet Contact dealer for help in correcting this situation 7 Contac...

Страница 11: ...ilicone Lubricant 1 11 Nipple Kit 1 12 Mounting Base 1 Replacement parts for FROG Leap Infuzer 7800 REF PART NO DESCRIPTION 1 2 01 22 1418 Cap w O Ring 2 01 22 1920 Cap O Ring 4 01 22 9480 Pressure Relief Valve 5 6 7 01 22 1443 Control Dial with O Rings and Locking Pin 6 01 22 1450 Control Dial O Ring Set 8 9 01 22 9940 Knob with O Ring 10 01 22 9971 Silicone Lubricant 11 01 22 1710 Nipple Kit 12 ...

Страница 12: ...Carefully insert control dial back into housing Replace locking pin by pushing it through the slots on the dial until it locks into place Hold cap in front of you upside down with the o ring groove facing up Place one end of o ring into cap groove at the point closest to you Hold o ring down with the thumb and index finger of one hand Take hold of the far end of the o ring with the thumb and index...

Страница 13: ...contains chlorine wrap in plastic bag and store in shed or cool well ventilated location away from children pets cars motorcycles or anything metal that can rust pit etc Make sure FROG Leap Torpedo Pac is away from open flame Remove the FROG Leap Anti Bac Mineral Pac and discard in trash Even if you hear spent minerals inside it is no longer effective Replace the cap and knob loosely ...

Страница 14: ... Screw one end of nipple into the filter return 1 2 Tighten turning 1 to 2 revolutions with wrench DO NOT OVER TIGHTEN Screw either side of FROG Leap Infuzer on to open nipple end until upright and secure Apply pipe thread tape or sealant to threaded end of hose adapter 3 4 Screw adapter into the other side of FROG Leap Infuzer Hand tighten Finish tightening by turning 1 to 2 revolutions with wren...

Страница 15: ...s be installed between the filter and pool or between heater and pool if applicable Above Ground Base Installation Screw adapters into each end of FROG Leap Infuzer Hand tighten Finish tightening by turning 1 to 2 revolutions with wrench DO NOT OVER TIGHTEN 2 Attach the filter section of flex hose to one hose adapter and the return section of flex hose to the other hose adapter with clamps and tig...

Страница 16: ...igher than needed can result in excess sanitizers being discharged into the pool If the sanitizer level goes unmonitored it can result in bleaching or discoloration of areas around the pool inlet or in some cases bleaching or discoloration of the entire pool liner or paint C Excess trichlor in the pool can create health hazards to bathers Consult each chemical manufacturer s warnings and cautions ...

Отзывы: