1.

3.

4.

5.

2.

Troubleshooting

1. Make sure your fi ltration 
system is working properly (i.e. 
clean fi lter, skimmer and pump 
basket).

2. Make sure circulation time 
is adequate – increase pump 

time if not.

3. Make sure the pool is 
properly balanced. 

(See page 10.)

4. Shock the water to eliminate 
build up of any organic matter.

5. Make sure pool has a 
free chlorine reading of 
0.5 to 1.0 ppm.

6. Check with your dealer 
for more information.

1. Algae may be trying to form 
– shock the pool, increase 
circulation time if needed and 
clean the fi lter. 

2. Metals in the fi ll water may 
have been oxidized. Have the 
pool tested. See pool dealer 
if a metal control product is 
required.

3. Check with your dealer for 
more information.

1. Use FROG Leap ALL-OUT or 
an effective algaecide per the 
directions on the bottle and 
brush the sides of the pool often.

2. Clean the fi lter and shock 
the pool with chlorine daily until 

water clarity returns.

3. If you are in an area of 
the country that struggles 
with algae growth, see your 
dealer regarding a 90-day 
Algae-Protection Guarantee 

using FROG Leap ALL-OUT.  

See product hang tag for 
guarantee details.

4. Check with your dealer for 
more information.

1. If you are unable to 
maintain 0.5 to 1.0 ppm, fi rst 
make sure there are chlorine 
tablets in the tower areas of 
the FROG Leap Torpedo Pac 
and it is installed properly. If a 
correction was made, test the 
water in 24 hours. 

2. If still low, turn the dial up 
one setting and test the water 
again in 24 hours. Continue 
raising the setting by one 
increment each day until the 

proper reading is achieved.

3. Shock the pool if the reading 
has been lower than 0.5 ppm 
for more than one day. 

4. Make sure pump run time is 
at least 6 hours on high speed 
(40 gpm or higher) or if not, 
bleed the air from the back 
knob each time cap is open. 

5. Contact your dealer to have 
your back pressure tested. If 
under 4 psi, consider a smaller 

eyeball fi tting in the return jet.

6. Check for a suction side 
leak by looking for air bubbles 
in your pump basket or at the 
return jet. Contact dealer for 
help in correcting this situation.

7. Contact King Technology’s 
Customer Service Department 
at 800-222-0169.

1. If the chlorine reading is 
over 3.0 ppm, remove the 
FROG Leap Torpedo Pac 
from the FROG Leap Anti-Bac 
Mineral Pac and test the water 
daily until the reading is down 
to 1.0 ppm.

2. Reinsert the FROG Leap 
Torpedo Pac, lower the dial 
one setting and test the 
water again in 24 hours. If 
the reading has risen, lower 
the dial one setting again. 
Continue this process until 

proper reading is achieved.  

3. If over-chlorinating at 
the lowest possible setting, 
consider decreasing the 
circulation time. Depending on 
your pump size, you may be 
circulating the water more than 
is necessary.

4. Contact your dealer to have 
your back pressure tested. If 
over 8 psi consider a larger 
eyeball fi tting in the return jet.

5. Check to see if the pressure 
relief valve is loose or missing 
and replace. It is a clear plastic 
piece approximately 1” long 
installed inside near the base. 
If loose or missing, it can 
provide another avenue for 
water to reach the chlorine.

6. Contact King Technology’s 
Customer Service Department 
at 800-222-0169. 

What do I do 
if I am over 
chlorinating with 
the FROG Leap 
Torpedo Pac?

What do I do 
if I am under 
chlorinating with 
the FROG Leap 
Torpedo Pac?

What do I do 
if algae forms in or 
on my pool?

What do I do 
if the water turns 
color?

What do I do 
if the water looks 
cloudy?

Problem

Remedy

For more in-depth troubleshooting, go to frogproducts.com or call King Technology at 800-222-0169.

Содержание 01-01-7820

Страница 1: ... Clearer because it helps keep pH in range Softer because it reduces chlorine use up to 50 Easier with pre filled pacs for no mess no guess and no stress To minimize the risk of serious injury death or damage before installing or first using this equipment read Instruction Manual and all safety labels and follow all safety instructions and precautions Save manual for future reference WARNING Ver l...

Страница 2: ...Step 2 Putting the System to Work 12 Step 3 Setting the Control Dial 13 Step 4 Routine Pool Care 14 Replacing FROG Leap Anti Bac Mineral Pac 15 Using FROG Leap Wake Up 16 Using FROG Leap ALL OUT 17 Using FROG Leap Torpedo Pac 18 Winterizing 19 Troubleshooting 20 Parts List 21 Maintenance Replacing Control Dial O Rings 22 Maintenance Replacing Cap O Rings and Knobs 22 Warranty 23 For information on...

Страница 3: ...ap Anti Bac Mineral Pac Product 01 03 7937 FROG Leap Anti Bac Mineral Pac comes inside the FROG Leap Infuzer and is also sold separately Also sold separately FROG Leap Torpedo Pac FROG Leap ALL OUT Product 01 10 7872 and FROG Leap Pool Wake Up Hibernation FROG Leap Mineral System consists of the FROG Leap minerals silver chloride and carbonate used in conjunction with 0 5 ppm chlorine The FROG Lea...

Страница 4: ...ctographs illustrate the type of hazard Pictograph Type of Danger Safety Alert General Hazard Explosion Risk Hazardous Pressure Flammable Fire Hazard Identification of warnings Warnings are intended to help you recognize risks and avoid death injuryorpropertydamage Thisishowwarningsareidentified Signal Word Pictographs Description of danger Consequences if ignored a The arrow signals a safety prec...

Страница 5: ... Charge and ALL OUT in the FROG Leap Infuzer Never use bulk chemicals a To prevent the build up of gas pressure in the FROG Leap Infuzer be sure the pool return line valves are open except when opening or servicing the unit a Do not inhale fumes from the FROG Leap Infuzer or FROG Leap Torpedo Pac a Avoid sparks smoking or any open flame near FROG Leap Infuzer or chemicals a Do not exceed maximum o...

Страница 6: ...n POOL RETURN FROG Leap Infuzer FROG Leap Infuzer FROG Leap Infuzer FROG Leap Infuzer IN FLOOR CLEANER VALVE FILTER FILTER HEATER OPTION 2 A 3 Way Valve Installation POOL WATER LEVEL 3 way manual valve or 3 way motor valve plus controls IN FLOOR CLEANER VALVE FILTER PUMP PUMP PUMP C Pool and Spillover Spa Combination Line 1 Line 2 POOL WATER LEVEL POOL WATER LEVEL WARNING Donotexceedmaximumoperati...

Страница 7: ... nipple 1 Screw either side of FROG Leap Infuzer on to open nipple end until upright and secure Apply pipe thread tape or sealant to threaded end of hose adapter 3 4 Screw adapter into the other sideofFROGLeapInfuzer Hand tighten Finish tightening by turning 1 to 2 revolutions with a pipe wrench DO NOT OVER TIGHTEN 5 6 Attach return section of hose to the adapter with clamp Tighten clamp with scre...

Страница 8: ... the return section of flex hose to the other hose adapter with clamps and tighten with screwdriver Bi flow valve design allows water flow in either direction 3 To prevent damage to heaters or filters see your dealer about installing a corrosion resistant check valve which will reduce the back flow of chlorine gas when the Infuzer is turned off 4 For better stability FROG Leap Infuzer may be mount...

Страница 9: ... Pipe Wrench Bi flow valve design allows installation in either flow direction Pipe Thread Tape or Sealant Primer and PVC Cement If using male adapters apply pipe thread tape or sealant to the threaded end of each adapter Screw adapters into each end of FROG Leap Infuzer following directions for a male adapter or a female adapter Hand tighten Finish tightening by turning 1 to 2 revolutions with a ...

Страница 10: ...re adding to the pool If calcium content is higher than 400 ppm find a soft water source to fill your pool instead otherwise water balance will be very difficult Check for metals in the pool such as iron or copper Before attempting water balance these should be removed See your dealer for a metal out or sequesterant and follow the label directions carefully Before beginning with any pool care prog...

Страница 11: ...easer Always maintain 200 400 ppm 5e Lastly test for stabilizer or conditioner levels Add conditioner if the level is below 20 ppm This will prevent chlorine burn off If stabilizer level is above 80 ppm partially drain water and re fill 6 5a Take a water sample from the pool and dip a FROG Test Strip into it For best results in achieving water balance follow steps 5a through 5e in order 6 2 6 8 7 ...

Страница 12: ... for 10 minutes on Setting 5 Insert FROG Leap ALL OUT into the open center of the FROG Leap Anti Bac Mineral Pac in the Infuzer See page 17 for directions Use FROG Leap ALL OUT for a 90 day Algae Protection Guarantee When chlorine reading is down to 1 0 ppm which may take a few days insert FROG Leap Torpedo Pac into the open center of the FROG Leap Anti Bac Mineral Pac See page 18 for directions 3...

Страница 13: ...0 gpm NR This pump size is not recommended for this size pool 24 HOUR LOW SPEED PUMP RUN TIME In order to ensure proper performance when running the pump on low speed for 24 hours per day or high speed less than 6 hours per day bleed the air while the pump is on by unscrewing the cap knob until water appears Then screw the knob back on Repeat this process each time the cap is removed for any reaso...

Страница 14: ...ical usage evaporation and the makeup of source water so maintaining water balance regularly is important WARNING TopreventthebuildupofgaspressureintheFROGLeap Infuzer besurethepoolreturnlinevalvesareopen except whenopeningorservicingtheunit DANGER Never add any other types of chlorine pH adjusters shock treatments or algaecides through the skimmer These products should be added directly into the ...

Страница 15: ...in inside the FROG Leap Infuzer Lower FROG Leap Anti Bac Mineral Pac into FROG Leap Infuzer until secure Replace the FROG Leap Torpedo Pac inside the FROG Leap Anti Bac Mineral Pac to continue operating system see directions on page 18 5 Mark your calendar ahead for the six month replacement of the FROG Leap Anti Bac Mineral Pac Once wetted the time released mineral coating of this product is effe...

Страница 16: ...th Charge FROG Leap Reveille Run the pump and filter for each pac according to the directions on the product label Remove from the FROG Leap Infuzer when empty and discard or offer for recycling Turn control dial on FROG Leap Infuzer to Setting 10 6 5 Line up the small leg of the FROG Leap Depth Charge or Reveille with the small opening in the FROG Leap Anti Bac Mineral Pac and the large leg with ...

Страница 17: ...urn control dial on FROG Leap Infuzer to Setting 10 2 3 4 5 Turn pump on for 90 minutes allowing FROG Leap ALL OUT to circulate through pool 6 To remove expended FROG Leap ALL OUT bottle turn pump off and turn dial to Setting 0 7 Remove FROG Leap Infuzer cap 8 Lift FROG Leap ALL OUT up and allow any water in the container to drain through the FROG Leap Infuzer before discarding in trash or offerin...

Страница 18: ...c until secure Using the FROG Leap Torpedo Pac FROG Leap Torpedo Pac is required to assure up to 50 reduction in chlorine use FROG Leap Torpedo Pac sold separately EPA Reg No 53735 2 2 3 4 5 6 7 Replace cap by hand only DO NOT OVER TIGHTEN The chlorine pac container is made of HDPE plastic Non refillable container Do not reuse or refill this container Offer for recycling if available Rinse thoroug...

Страница 19: ... chlorine wrap in plastic bag and store in shed or cool dry well ventilated location away from children pets cars motorcycles or anything metal that can rust pit etc If empty rinse and recycle Remove the FROG Leap Anti Bac Mineral Pac and discard in trash You will hear spent media inside however it is no longer effective Replace the cap and knob loosely 2 6 FROG Leap Depth Charge FROG Leap Reveill...

Страница 20: ...me is at least 6 hours on high speed 40 gpm or higher or if not bleed the air from the back knob each time cap is open 5 Contact your dealer to have your back pressure tested If under 4 psi consider a smaller eyeball fitting in the return jet 6 Check for a suction side leak by looking for air bubbles in your pump basket or at the return jet Contact dealer for help in correcting this situation 7 Co...

Страница 21: ...Replacement parts for FROG Leap Infuzer 7800 REF PART NO DESCRIPTION 1 2 01 22 1416 Cap w O Ring 2 01 22 1920 Cap O Ring 4 01 22 9486 Pressure Relief Valve 5 6 7 8 01 22 1457 Control Dial with O Rings Locking Pin and Number Plate 6 01 22 1456 Control Dial O Ring Set 9 10 01 22 9627 Knob with O Ring 11 01 22 1481 Mounting Base 12 01 22 9971 Silicone Lubricant 3 4 oz 13 01 22 1710 Nipple Kit 14 01 2...

Страница 22: ... slots on the dial until it locks into place Lubricate o ring every couple of months with silicone lubricant that came with your FROG Leap Infuzer DO NOT USE petroleum based lubricants 1 1 2 2 3 4 5 5 SILICONE LUBRICANT Place new o ring in bottom half of groove Place your thumbs on each side of the cap over the o ring in the groove Roll your thumbs back and forth over the o ring while pushing upwa...

Страница 23: ...panying instructions This warranty also excludes all costs arising from the installation adjustment removal or replacement of defective units or parts This warranty also excludes any and all claims arising out of the chemicals used in the product or their characteristics Made in U S A Patents kingtechnology com IP 3 Any express warranty not provided for herein and any remedy for breach of warranty...

Страница 24: ...ology Inc FROG Flippin FROG FILTER FROG FROG Jump Start FROG Leap Flippin FROG XL INSTANT FROG Fresh Mineral Water POOL FROG FROG BAM ease New Water POOL FROG XL PRO SPA FROG SmartChlor Perform Max 530 11TH AVE S HOPKINS MN 55343 800 222 0169 frogproducts com 20 48 2022 553111743R5N ...

Отзывы: