background image

6

RDPR-HP-1 User’s Manual

Led IndICAtoRs

Power

With detect on

 

(Refer to the Mode Settings, page 11)

Solid - Ready for operation. 
Blinking - Not ready for operation.

With detect off

 

(Refer to the Mode Settings, page 11)

Solid - Master Power switch is on. 

Repeat 1

When lit, Radio 2 (left side) is repeating the received 

signal from Radio 1 (right side).

Repeat 2

When lit, Radio 1 (right side) is repeating the 

received signal from Radio 2 (left side).

Repeat 1

and

Repeat 2

When lit, Radio 1 and Radio 2 are repeating the 

received signal from the radio connected to the 

external port. (If configured “Cross-Band Linked 

Repeater”, page 12)

sWItChes

Power

Master switch to power-up the RDPR-HP-1.

Repeater

Switches power to the “Radio 1 PWR” and “Radio 2 

PWR” ports to enable/disable repeater function.

Radio 2/Mobile

Switches Radio 2 off when using the external radio 

port.

VoX/CoR

Switches between voice/noise activated (VOX) or 

carrier activated (COR) repeat function.

note: BK Radio portables must be set for VoX 

operation. 

duplexer

(ReQuIRes LZA3050)

Activates and deactivates the duplexer.
Refer to Duplexer Switch Option on page 10.

sW6

Refer to the Mode Settings on page 11.

Содержание RDPR-HP-1

Страница 1: ......

Страница 2: ...nnections 5 LED Indicators 6 Switches 6 Basic Operation 7 Mobile Extender 7 Linking 8 SINCGARS 8 Antenna Installation 9 Duplexer Option 10 Duplexer Switch Option 10 Mode Settings 11 Service 12 Quick Reference 13 Basic Configuration 13 External Radio Configuration 14 In Band Linking Configuration 15 Cross Band Linking Configuration 16 Power Supply Configuration 17 Schematic 18 ...

Страница 3: ... environment The portability and ease of use allows it to be easily deployed in the most demanding environments Please take a moment to read the information in this manual so you can get optimum performance from your new Portable Repeater Also please refer to the Owner s Manual of the respective radios that are configured in your portable repeater for safety and operation information PART INCLUDED...

Страница 4: ...Nut Interface connectors and mounting plates are dependant radio set type Contact RELM Wireless for available radio types Weather Proof Case Radio Sets Basic Configuration AVAILABLE OPTIONS LZA3015 A6 Factory Installed Duplexer 136 148MHz LZA3015 B6 Factory Installed Duplexer 148 160MHz LZA3015 C6 Factory Installed Duplexer 160 174MHz LZA3017 A6 Factory Installed Duplexer 380 400MHz LZA3017 B6 Fac...

Страница 5: ... Antenna N Type MWV1360S Mobile Antenna 136 174MHz w Spring MWU4002S Mobile Antenna 406 512MHz w Spring AVAILABLE CABLE ASSEMBLIES CABANTRDPR 25FT Antenna Coax Cable CABANTRDPR50 50FT Antenna Coax Cable N to UHF CABANTRDPR50N 50FT Antenna Coax Cable N to N MECRDPR2 Mobile Extender Cable Metal Conn LINKCRDPR2 Mobile Extender Link Cable PWRCBLHP Power Cable EBS RDPR to RDPR HP AVAILABLE MOUNTING KIT...

Страница 6: ...IO PORT 1 VOX COR RADIO 1 PWR OFF OFF OFF POW ER RADIO 2 RADIO 2 PWR VOX COR RADIO 2 PORT 2 RADIO RF 2 INPUT ON REPEATER ON POW ER REPEAT 2 REPEAT 1 EXTERNAL RADIO 1 INPUT RF 1 RADIO 2 RADIO 1 OFF ON DUPLEXER Radio 2 Power Radio 1 Power Antenna Port 2 Duplexer Port Mobile Extender Link Port SW6 Access Antenna Port 1 Radio 2 Port Radio 1 Port Radio RF Ports DC Supply Port LED and Switch Array See D...

Страница 7: ... and Radio 2 are repeating the received signal from the radio connected to the external port If configured Cross Band Linked Repeater page 12 Switches Power Master switch to power up the RDPR HP 1 Repeater Switches power to the Radio 1 PWR and Radio 2 PWR ports to enable disable repeater function Radio 2 Mobile Switches Radio 2 off when using the external radio port VOX COR Switches between voice ...

Страница 8: ...Do not set volume knob past the 12 o clock position Use a service monitor or compatible transmitter and receiver to test the repeat function Mobile Extender MECRDPR2 The Mobile Extender Cable MECRDPR2 allows the use of a BK Radio mobile as the transmitting unit to take advantage of the mobile radio s higher RF power output Connect the modular plug 1 of the MECRDPR2 into the mobile radio s micropho...

Страница 9: ... the MECRDPR2 into the accessory port at the rear of the mobile or base station and connect the other end to the Mobile Extender Link Port of the RDPR HP 1 Switch the RDPR HP 1 main 2 power and repeater power on Switch the mobile or base 3 station power on Refer to the Mode Settings page 12 for linking options SINCGARS SINCGARS_LINK2 The SINCGARS Link Cable SINCGARS_LINK2 is used to connect RDPR H...

Страница 10: ...ntenna Mast Make sure that the RF connector is positioned away from the pole or mast Tighten the hose clamps 3 Insert the 4 radials into the holes 4 located on the antenna base Using the supplied hex wrench tighten the set screw for each radial Screw the antenna to the top of 5 antenna mount Connect the PL259 connector of the coax cable to the bottom 6 connector of the antenna base Connect the N c...

Страница 11: ...t the top panel from the front to gain access to the 3 duplexer Remove the antenna cable from the duplexer and from Antenna 4 Port 2 Remove the RX and TX antenna connection from the duplexer 5 and re connect to the respective RDPR HP 1 antenna ports Duplexer SWITCH Option LZA3050 If the RDPR HP 1 comes with duplexer option LZA3015 VHF or LZA3017 UHF the LZA3050 Duplexer Switch can be ordered Facto...

Страница 12: ... of the radios are turned off or not plugged in the power LED will flash and the repeater function will be inoperable OFF ON SW6 1 2 3 4 S3 OFF The repeater function is operable even if one of the radios is off or unplugged NOTE This setting is used when only one of the RDPR HP 1 internal Radio Sets is being used in conjunction with an external radio Linking Configurations S4 In Band Linked Repeat...

Страница 13: ...en using this option the hang time must be set to zero seconds Refer to Hang Time Settings page 12 S4 OFF Transmitting Radio Radio 1 Radio 2 External Receiving Radio Radio 1 X X Radio 2 X X External X X Service If you need service contact your local BK Radio dealer equipped to service your radio If you find it impractical to have service performed by your local dealer contact BK Radio at the addre...

Страница 14: ...c Configuration RDPR HP 1 Radio 1 Radio 2 Signal In Signal Out Basic Configuration RDPR HP 1 Radio 1 Radio 2 Signal Out Signal In A GND B N C C N C D B A B C D E F C A D B A SWA B PTT C GND D MIC_HI E SPKR COR F SPKR DC Supply Port Extender Link Port ...

Страница 15: ...er Supply Signal Out With Radio 2 Switch OFF RDPR HP 1 Radio 1 Radio 2 Signal In Signal Out External Radio External Radio Power Supply Signal Out External Radio Configuration With Radio 2 Switch ON RDPR HP 1 Radio 1 Radio 2 Signal Out Signal In External Radio External Radio Power Supply Signal Out ...

Страница 16: ...and Linking Configuration RDPR HP 1 Radio 1 Radio 2 Signal In Signal Out External Radio External Radio Power Supply Signal Out RDPR HP 1 Radio 1 Radio 2 Signal Out External Radio External Radio Power Supply Signal In S4 On ...

Страница 17: ...2 Signal In Signal Out External Radio External Radio Power Supply Signal Out RDPR HP 1 Radio 1 Radio 2 Signal In External Radio External Radio Power Supply Signal Out Signal Out RDPR HP 1 Radio 1 Radio 2 Signal Out External Radio External Radio Power Supply Signal In Signal Out S4 Off ...

Страница 18: ...17 RELM BK Radio Power Supply Configuration RDPR HP 1 DC IN ANT ANT WPSRDPR HP RDPR HP 1 DC IN ANT ANT CABAUTO12VRDPR HP RDPR HP 1 DC IN ANT ANT EBS RDPR DC OUT PWRCBLHP ...

Страница 19: ...18 RDPR HP 1 User s Manual Schematic 3333 31015 600 ver A Sheet 1 of 3 ...

Страница 20: ...19 RELM BK Radio Schematic 3333 31015 600 ver A Sheet 2 of 3 ...

Страница 21: ...20 RDPR HP 1 User s Manual Schematic 3333 31015 600 ver A Sheet 3 of 3 ...

Отзывы: