3. Internal Wiring Instructions
OUTX (white):
The output of the relay is connected with the
electromagnetic switch, used to control the door.
PJ1 (red and black):
External power supply, the use of 9~24VDC,
pay attention to distinguish between positive(red) and negative(black).
RST:
Reset, jumper wire connection, and then boot, after 10 seconds,
disconnect, Restore factory settings (reset does not clear user’s number
information).
J4 (yellow):
Connect to door switch.
4. Setup and Operation
This device is set up and operated by SMS. All of the following letters are uppercase letters.
Password factory default is 1234, "+" is not the message content
,
Such as equipment time command:
1234TEL13812345678#. Each instruction will receive the corresponding information or action of the
feedback from the device. If you do not receive feedback, indicate that the device did not receive the
instruction, please check whether the card is inserted and the card is valid.
◆
The equipment time calibration
Pa TEL + equipment number#
For the first time or when you want to change your phone card.
◆
Modify the password
Current pa P + new password
◆
Set the user number
Pa A + serial number# + user phone number#
or
Pa A + serial number# + user phone number# + start time# + end time#
Serial number : 001~200
;