background image

 

 

3. Internal Wiring Instructions 

 

OUTX (white): 

The output of the relay is connected with the 

electromagnetic switch, used to control the door. 

 

 

PJ1 (red and black): 

External power supply, the use of 9~24VDC, 

pay attention to distinguish between positive(red) and negative(black). 

 

RST: 

Reset, jumper wire connection, and then boot, after 10 seconds, 

disconnect, Restore factory settings (reset does not clear user’s number 

information). 

 

J4 (yellow): 

Connect to door switch. 

 

 
 
4. Setup and Operation 

This  device  is  set  up  and  operated  by  SMS.  All  of  the  following  letters  are  uppercase  letters. 

Password factory default is 1234, "+" is not the message content

Such as equipment time command: 

1234TEL13812345678#. Each instruction will receive the corresponding information or action of the 

feedback from the device. If you do not receive feedback, indicate that the device did not receive the 

instruction, please check whether the card is inserted and the card is valid. 

 

 

The equipment time calibration 

Pa TEL + equipment number# 

For the first time or when you want to change your phone card. 

 

 

Modify the password 

Current pa P + new password 

 

 

Set the user number

 

Pa A + serial number# + user phone number#   

or 

Pa A + serial number# + user phone number# + start time# + end time# 

Serial number : 001~200

 

Содержание K6S

Страница 1: ...ess control system it supports dial to open the door with free call charge can remote open the door for visitors very suitable for different office villas and public occasion User s Manual Ver 3 1 Date 2018 04 10 Download APP Apartment Intercom ...

Страница 2: ...gain then recovery SMS commands can be used to query the current state of the host relay status and GSM signal value SMS can be regularly uploaded for the current state of the host to the first user number Use the clock on the module each time the host sends SMS to itself to correct the time 2 Host Overview Microphone Relay door indicator lamp relay close on relay open off Signal lamp GSM version ...

Страница 3: ...owing letters are uppercase letters Password factory default is 1234 is not the message content Such as equipment time command 1234TEL13812345678 Each instruction will receive the corresponding information or action of the feedback from the device If you do not receive feedback indicate that the device did not receive the instruction please check whether the card is inserted and the card is valid ...

Страница 4: ...ncoming to control relay Password ALL Set only user number available of incoming to control relay default Password AUT Set relay activity time Password GOT the activity time activity time is 000 999 Unit second The activity time is set to 000 default which means that the user will automatically recovery when the relay is activity for about 0 5 seconds The activity time is set to 999 which means th...

Страница 5: ...ult Password GOFF11 Content of SMS 2 Set to return SMS to the first number not to the incoming number after the relay open Password GOFF10 Content of SMS 3 Set to return SMS to the incoming number not to the first number after the relay open Password GOFF01 Content of SMS 4 Set not to return SMS after the relay open Password GOFF SMS control relay close on Password CC SMS control relay open off Pa...

Страница 6: ...device will continue to call next authorize number without pressing the key on the phone If press then open the door and stop calling next one Press or 0 9 will not open the door and not call next authorize number Set calling time Password COT calling time Calling time 0 65536 unit second default 60 it means the calling will be hung up automatically once the calling time arrives 60s 0 means the ca...

Страница 7: ...word GON ab SMS content a b 0 or 1 a corresponds to the first number b corresponds to the number of incoming calls 0 not to return 1 to return Return SMS after relay open off Password GOFF ab SMS content Not to return SMS after relay close on Password GON Not to return SMS after relay open off Password GOFF Control the relay close on Password CC Control the relay open off Password DD Query device ...

Отзывы: