Page 9 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 9 of 16 Ver 1.0 File No.:RTU501610
A Professional GSM Alarm System designer and manufacturer!
GSM Transformer Alarm System &GSM House Alarm System&
GSM Telemetry Units & GSM GPRS Logging System
Http://www.GSMalarmsystem.com [email protected]
Tips:
1. the authorized number means the one who can receive the RTU5016 unit warning SMS text.
2.We strongly recommend that these numbers are cellphone numbers, because of the alarm
message only send by SMS text;
3. The Serial Number is the position to store the authorized number, from 01~05.
6.3 Remove the Authorized Number
(
or you can overwrite with another number you wish to change it).
E.g.: if you want to remove the authorized number at position 05, and the password is 1234, then you can
send
1234#TEL#05#
6.4 Inquiry the Authorized Number
6.5 Inquiry the assigned IR value information
After the RTU5016 received, will return:
Tips:
The GSM SMS IR Controller can be saved 5 different temperature value, The T1 position is for
assigning IR ON/OFF Air-Conditioner value, the T2~T6 positions are for assigning IR Temperature value,.
6.6 Setup Low Temperature Alarm Value and Actions
1) Enable low temperature alarm function:
pwd#TEL#
-----stands for the T1 position has been assigned the ON/OFF Value, the
T1 is special for assigning the Conditioner’s IR ON/OFF Value ;
-----stands for the T2 position has been assigned a IR Value;
-----stands for the T3 position has been assigned a IR Value;
-----stands for the T4 position hasn’t been assigned any IR Value;
-----stands for the T5 position hasn’t been assigned any Value;
-----stands for the T6 position has been assigned a IR Value.
Temp set 1 is Power Off
;
Temp set 2 is En
;
Temp set 3 is En
;
T4---
;
T5---
;
Temp set 6 is En
;
pwd#READ#
Tel 1: 004413500001111;
Tel 2: Empty;
Tel 3: Empty;
Tel 4: Empty;
Tel 5: Empty.
pwd#TEL#Serial Number#
pwd#LOW#ON#