1)  Temperature Monitoring alarm application, e.g.: Send SMS to inquiry the current temperature; 

2)  Air-Conditioner Remotely management, e.g.: Switch ON Air-Conditioner and setup the temperature 

value; 

3)  Infrared Remote Control equipments, e.g: Switch on/Off the Air-Conditioner; 

4)  Warehouses and Laboratory room, e.g.: Monitoring the temperature, higher or lower should send SMS 

warning to owners. 

5)  Automatically monitoring the temperature within the preset range, e.g.: Higher than 25

 should 

automatically switch on Air-Conditioner and send SMS to owners, low than 10

 should automatically 

switch on the heater Air-Conditioner to heat up the temperature and warning owners by SMS. 

6)  Switch ON/OFF equipments, e.g.: motor, Air-Conditioner, and other electronic equipments. 

2.Safety Directions 

Safe Startup 

Do not use GSM SMS IR Controller when using GSM equipment is prohibited or might bring 
disturbance or danger.   
 

Interference 

All wireless equipment might interfere network signals of GSM SMS IR Controller and 
influence its performance. 
 

Avoid Use at Gas Station 

Do not use GSM SMS IR Controller at a gas station. Power off GSM SMS IR Controller 
when it near fuels or chemicals. 

 

Power it off near Blasting Places 

Please follow relevant restrictive regulations. Avoid using the device in blasting places. 

 

Reasonable Use 

Please install the product at suitable places as described in the product documentation. 
Avoid signal shielded by covering the mainframe. 
 

Use Qualified Maintenance Service

 

Maintenance can be carried out only by qualified maintainer. 
 
 

3. Standard Packing List 

Содержание GSM SMS IR CONTROLLER RTU5016

Страница 1: ...GSM Telemetry Units GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn Automatically monitoring Air Conditioner by SMS Text Remotely Control Air Conditioner by SMS Text Tempe...

Страница 2: ...ty 15 This handbook has been designed as a guide to the installation and operation of RTU5016 GSM SMS IR Controller Statements contained in the handbook are general guidelines only and in no way are d...

Страница 3: ...authorized temperature monitoring remote control Air Conditioner Actually the GSM SMS IR Controller RTU5016 can be used in places which require to use Infrared Remote to control e g Air Conditioner Te...

Страница 4: ...o owners low than 10 should automatically switch on the heater Air Conditioner to heat up the temperature and warning owners by SMS 6 Switch ON OFF equipments e g motor Air Conditioner and other elect...

Страница 5: ...been reset to default settings Learning This button for learning IR Air Conditioner s Infrared Remote Transmitter OFF T1 6 T1 Position Led when learning IR signal to T1 will flick after learned succe...

Страница 6: ...de 25 10K 1 precision included in standard package input to convert the temperature to digital value 2 Lower or Higher warning temperature threshold value can be configured 3 Can inquire the current t...

Страница 7: ...tc Don t add spaces or any other character When input punctuation symbol must be under ENGLISH or DIGITAL input method Not support other input method 5 When external AC goes off and goes on will send...

Страница 8: ...s 1234 then you can send 1234 TEL004413500001111 01 to the RTU5016 unit After the RTU5016 received the 0044 is country code will return For example In UK the country code is 0044 or 44 The user cell p...

Страница 9: ...thorized Number 6 5 Inquiry the assigned IR value information After the RTU5016 received will return Tips The GSM SMS IR Controller can be saved 5 different temperature value The T1 position is for as...

Страница 10: ...itch On the Air Conditioner automatically when low temperature alarm occurrence Reply Tips in Tx the x 1 6 Stands for T1 T6 This command means when low temperature alarm will switch on the Air Conditi...

Страница 11: ...temperature alarm occurrence Reply 7 Switch On the Air Conditioner automatically when High temperature alarm occurrence Reply Tips The Tx is the same means of abovementioned x 1 6 Please pay attentio...

Страница 12: ...immediately 6 9 Switch OFF the Relay Output Reply 6 10 Switch ON Air Conditioner and setup its temperature The Tx stands for T2 T6 T1 is special for switch off the air conditioner please see 6 11 For...

Страница 13: ...l saved IR Transmitter signals at T1 T6 And enter into learning mode The T1 Led will flick and the Status Led will be red and green color Step2 Press the Learning Button till the Status Led change to...

Страница 14: ...d the signal will save it at position T2 2 When you want to learn the Switch OFF button function to the GSM SMS IR Controller then press the Learning Button when the T1 Led flicks and status led is re...

Страница 15: ...mission range and there re with a power source as well as enough GSM signal coverage The distance from the GSM SMS IR Controller must be less than 3meters to the Air Conditioner 8 Technical specificat...

Страница 16: ...ler off and switch it on after one minute Test this system after another minute or check the settings are correct and the GSM Signals are strong enough 3 If the GSM SMS IR Controller can run and senso...

Отзывы: