LEAK TEST INSTRUCTIONS
14
Before lighting the appliance, a thorough leak test must be satisfactorily completed using
a non-ammonia soapy water solution (50% non-ammonia soap and 50% water). This is to
be applied with a small brush to all gas joints (quick disconnect socket to gas supply piping
assembly, appliance hose to quick disconnect socket assembly, appliance hose to the brass
adapter assembly and the brass adapter to appliance valve assembly) after the appliance hose
is inserted into the quick disconnect socket. See Figure 1 below. Turn the shutoff valve located
between the quick disconnect socket and gas supply to the ON position to allow gas flow. Leave
the appliance valve in the OFF position during the leak check.
If bubbles are seen, indicating a leak, turn off the gas supply shutoff valve and remove the
appliance hose from the quick disconnect socket. Tighten the leaking connection until a further
leak test shows no leaks. Check for gas leaks every time you use the appliance or disconnect
and reconnect a gas fitting.
If tightening the connection does not stop the leak, call Metal Fusion, Inc. (800) 783-3885,
for assistance.
NEVER USE APPLIANCE IF LEAKING.
NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.
SHUT-OFF VALVE
TURN TO “ON” POSITION FOR LEAK CHECK.
SHUT-OFF VALVE
TURN “OFF” WHEN FINISHED OR IF LEAK IS DETECTED.
GAS SUPPLY
PIPING
GAS SUPPLY
PIPING
QUICK DISCONNECT
SOCKET
QUICK DISCONNECT
SOCKET
APPLIANCE
HOSE
APPLIANCE
HOSE
FIGURE 1
APPLIANCE
HOSE
APPLIANCE VALVE
(LEAVE IN “OFF” POSITION
DURING LEAK CHECK)
BRASS
ADAPTER
3/8 FEMALE
FLARE SWIVEL
PIPE
NIPPLE
* Model May Vary From Picture