background image

ELECTRICAL INFORMATION

WARNING!

ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN SE-

RIOUS INJURY! ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE MACHINE DISCONNECTED FROM THE POWER

SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!

POWER SUPPLY

WARNING:

YOUR JOINTER MUST BE CONNECTED TO A 110V-120V,  15-

AMP CIRCUIT BREAKER. FAILURE TO CONNECT IN THIS WAY CAN RE-

SULT IN INJURY FROM SHOCK OR FIRE.

GROUNDING

This Jointer must be grounded. If it should malfunction or breakdown, ground-

ing provides a path of least resistance for electric current, to reduce the risk

of electric shock. This Jointer is equipped with a cord having an equipment-

grounding conductor and grounding plug. The plug must be plugged into an

appropriate outlet that is properly installed and grounded in accordance with

all local codes and ordinances.

Your  Jointer  must  be  properly  grounded.  Not  all  outlets  are  properly

grounded. If you are not sure if your outlet is properly grounded, have it

checked by a qualified electrician.

WARNING: 

TO MAINTAIN PROPER GROUNDING OF YOUR JOINTER, DO

NOT REMOVE OR ALTER THE GROUNDING PRONG IN ANY MANNER.

WARNING:

IF NOT PROPERLY GROUNDED, THIS JOINTER CAN CAUSE

ELECTRICAL SHOCK, PARTICULARLY WHEN USED IN DAMP LOCA-

TIONS. TO AVOID SHOCK OR FIRE, IF THE POWER CORD IS WORN OR

DAMAGED IN ANY WAY, HAVE IT REPLACED IMMEDIATELY.

110V-120V OPERATION

As received from the factory, your Jointer is ready to run for 110V-120V op-

eration. This Jointer is intended for use on a circuit that has an outlet and a

plug which looks like the one illustrated in Fig.1.

WARNING:

DO NOT USE A TWO-PRONG ADAPTOR FOR THEY ARE NOT

IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES. NEVER USE

IN CANADA.

EXTENSION CORDS

The use of any extension cord will cause some loss of power. Use the     chart

in Fig.2 to determine the minimum wire size (A.W.G-American Wire Gauge)

extension cord. Use only 3-wire extension cords which have 3-prong ground-

ing type plugs and 3-hole receptacles which accept the tool’s plug.

For circuits that are further away from the electrical circuit box, the wire size

must be increased proportionately in order to deliver ample voltage to the

Jointer motor. Refer to Fig.2 for wire length and size.

SAFETY SWITCH

This machine is supplied with a safety switch (A) Fig.3 equipped with a re-

movable safety key (B). To turn the machine ON make sure the yellow safety

key is inserted and pull the switch up, to the ON position. To turn the machine

OFF push the switch to the OFF position. To prevent unauthorized use of

your machine remove the safety key and store it in a secure location.

FIGURE 1

FIGURE 2

PROPERLY GROUNDED OUTLET

CURRENT CARRYING PRONGS

GROUNDING PRONG

Tool’s

Amperage

Rating

3-6

6-8

8-10

10-12

12-16

Cord Size in A.W.G.

Cord Length in Feet

   25     50    100   150
   

18

    

16

    

16

     

14

   

18

    

16

    

14

     

12

   

18

    

16

    

14

     

12

   

18

    

16

    

14

     

12

   

14

    

12

      

-

       

-

FIGURE 3

Содержание KC-6HJC

Страница 1: ...INSTRUCTION MANUAL MODEL KC 6HJC COPYRIGHT 2016 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC 6 BENCHTOP JOINTER WITH HELICAL CUTTERHEAD 08 2016...

Страница 2: ...and lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To ta...

Страница 3: ...n changing accessories or attachments 16 AVOID ACCIDENTAL STARTING Make sure the swich is in the OFF position before plugging in 17 USE RECOMMENDED ACCESSORIES Consult the manual for recommended acces...

Страница 4: ...nt knob 10 Fence tilt locking lever 11 Fence adjustment locking lever 12 Fence support arm 13 Fence mounting bracket 14 Belt guard Specifications MODEL KC 6HJC Capacity 6 Depth of cut capacity 1 8 Cut...

Страница 5: ...GED IN ANY WAY HAVE IT REPLACED IMMEDIATELY 110V 120V OPERATION As received from the factory your Jointer is ready to run for 110V 120V op eration This Jointer is intended for use on a circuit that ha...

Страница 6: ...ure it by tightening the 2 round head allen screws 5 Sit the fence bracket A Fig 6 on the support arm B Slip the threaded end of the fence lock handle C with flat washer D through the bracket and supp...

Страница 7: ...e retighten the fence tilt lock handle A by turning handle clockwise Make sure this is done before jointing the workpiece ADJUSTING THE FENCE POSITIVE STOPS 90 Positive Stop Adjustment 1 With the fenc...

Страница 8: ...table to its highest point level with the top of the cut terhead 2 Place a straigtedge across the tables and cutterhead to validate the infeed table is level with the cutterhead 3 Using a hex key loos...

Страница 9: ...gainst the table and tight to the fence and guide the board along the table and over the cut terhead 6 Turn off the jointer and inspect the edge of the board repeat the jointing steps as needed until...

Страница 10: ...te There is an etched reference mark on each insert to help keep track of which cutting surface to use Make sure to rotate all inserts so that the reference mark sits in the same position on all inser...