COMPRESSOR CONTROLS

ADDITIONAL REGULATORS AND CONTROLS

Since the air tank pressure is usually greater than that which is needed, an
air pressure regulator is employed to control the air pressure ahead of any
individual driven device. Seperate air transformers which combine the
function of air regulation, moisture and dirt removal should be used where
applicable. 

OPERATION CONTROLS

CHECK VALVE (A) FIG.7. 

When the air compressor is operating, the check

valve is “open”, allowing compressed air to enter the air tank. When the air
compressor reaches its “Cut-Out” pressure, the check valve “closes”,
allowing air pressure to remain inside the air tank.

TANK PRESSURE GAUGE (A) FIG. 8.

The tank pressure gauge indicates

the reserve air pressure in the tank.

ON/AUTO-OFF SWITCH (B) FIG.8. 

Turn this switch ON to provide power to

the automatic pressure switch and OFF to remove power at the end of each use.

PRESSURE SWITCH (C) FIG.8. 

The pressure switch automatically starts the

motor when the tank pressure drops below the factory set “Cut-In” pressure.
It also stops the motor when the air tank pressure reaches the factory set
“Cut-Out” pressure.

ASME SAFETY VALVE (D) FIG. 8.

If the pressure switch does not shut off

the air compressor at its cutout pressure setting, the safety valve will protect
against high pressure by “popping out” at its factory set pressure (slightly
higher than the pressure switch cut-out setting).

WARNING!

: If the safety valve does not work properly, over pressurization

may occur, causing air tank rupture or an explosion. Daily pull the ring on the
safety valve to make sure that the safety valve operates freely. If the valve is
stuck or does not operate smoothly, it must be replaced with the same ASME
type of valve.

OUTLET PRESSURE GAUGE (E) FIG. 8.

The outlet pressure gauge

indicates the air pressure available at the outlet side of the regulator. The
pressure is controlled by the regulator and is always less than or equal to the
tank pressure. 

REGULATOR (F) FIG.8. 

The air pressure coming from the air tank is

controlled by the regulator. To unlock the regulator, pull it outwards then turn
the regulator knob clockwise to increase pressure or counterclockwise to
decrease pressure. To avoid minor readjustment after making a change in the
pressure setting, always approach the desired pressure from a lower
pressure. When reducing from a higher to a lower setting, first reduce the
pressure less than that desired, then bring it up to the desired pressure.
Depending on the air requirements of each particular accessory, the outlet
regulated air pressure may have to be adjusted while operating the accessory.

DRAIN VALVE (A) FIG.9.

The drain valve is located at the base of the air

tank and is used to drain condensation at the end of each use. Turn drain
valve clockwise to open (no pressure build-up) or counterclockwise to close
it (permits pressure build-up).

MOTOR THERMAL OVERLOAD PROTECTOR (RESET (A) FIG.10).

The

electric motor has an automatic thermal overload protector. If the motor
overheats for any reason, the thermal overload protector will shut off the
motor. The motor must be allowed to cool before restarting. Wait for motor to
cool down, once motor is cool, press the reset button and restart.

FIGURE 7

FIGURE 8

FIGURE 9

FIGURE 10

Содержание KC-3124V1

Страница 1: ...INSTRUCTION MANUAL MODEL KC 3124V1 COPYRIGHT 2013 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC 5 5 PEAK HP 24 GALLON AIR COMPRESSOR 09 2013...

Страница 2: ...lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To take a...

Страница 3: ...system RISK OF BURNS WHAT CAN HAPPEN Touching exposed metal such as the compressor head or outlet tubes can result in serious burns HOW TO PREVENT IT Never touch any exposed metal parts on compressor...

Страница 4: ...t grounding conductor and grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING TO MAINTA...

Страница 5: ...CLOSELY FOLLOWED THESE PROCEDURES ARE REQUIRED BEFORE THE AIR COMPRESSOR CAN BE PUT INTO SERVICE AFTER REPLACING THE CHECK VALVE AND WHEN A PISTON OR A CYLINDER SLEEVE ARE REPLACED 1 Make sure the pre...

Страница 6: ...on Daily pull the ring on the safety valve to make sure that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same ASME type of valve OU...

Страница 7: ...he centre of the red dot of oil sight glass 2 Drain condensation from tank 3 Check for any unusual noise or vibration 4 Be sure all nuts and bolts are tight Monthly 1 Inspect air system for leaks by a...

Страница 8: ...ure Restricted air filter Wrong oil viscosity Oil level too high Crankcase breather valve malfunction Worn piston rings Piston rings not seated CORRECTIVE ACTION Check voltage or eliminate extension c...

Отзывы: