background image

ELECTRICAL CONNECTIONS

WARNING!

ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN
SERIOUS INJURY! ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE  BANDSAW DISCONNECTED FROM THE
POWER SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!

POWER SUPPLY

WARNING:

YOUR BANDSAW MUST BE CONNECTED TO A 240V, 30-

AMP, BRANCH CIRCUIT AND USE A 30-AMP TIME DELAY FUSE
OR CIRCUIT BREAKER. FAILURE TO CONNECT IN THIS WAY CAN
RESULT IN INJURY FROM SHOCK OR FIRE.

Your bandsaw must be properly grounded. Not all outlets are 
properly grounded. If you are not sure if your outlet is properly
grounded, have it checked by a qualified electrician.

WARNING:

IF NOT PROPERLY GROUNDED, THIS BANDSAW CAN

CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN USED IN
DAMP LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER
CORD IS WORN OR DAMAGED IN ANY WAY, HAVE IT REPLACED
IMMEDIATELY.

GROUNDING

This bandsaw must be grounded. If it should malfunction or 
breakdown, grounding provides a path of least resistance for electric
current, to reduce the risk of electric shock. This band saw is equipped
with a cord having an equipment-grounding conductor and grounding
plug. The plug must be plugged into an appropriate outlet that is pro
perly installed and grounded in accordance with all local codes and
ordinances.

WARNING: 

TO MAINTAIN PROPER GROUNDING OF YOUR 

BANDSAW, DO NOT REMOVE OR ALTER THE GROUNDING
PRONG IN ANY MANNER.

240V OPERATION

As received from the factory, your bandsaw is ready to run for 240V
operation. This bandsaw is intended for use on a circuit that has an 
outlet and a plug which looks like the one illustrated in Fig.B.

WARNING:

DO NOT USE A TWO-PRONG ADAPTOR FOR THEY ARE

NOT IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES.
NEVER USE IN CANADA.

120V OPERATION

If 120V, single phase operation is desired, the following instructions
must be followed:
1. Disconnect the machine from its power source.
2. The bandsaw comes with four motor leads that are connected for

240V operation. Reconnect these four motor leads for 120V
operation, have a qualified electrician reconnect the motor leads.

3. The 240V plug supplied with the bandsaw must be replaced with a

CSA listed plug suitable for 120V operation. This plug is illustrated
in Fig.A. Contact your authorized service center or qualified 
electrician to install the plug and to change the connections from
240V to 120V. The bandsaw must comply with all local and national
codes after the 120V  plug is installed.

4. A bandsaw with a 120V plug should only be connected to an outlet

having the same configuration as illustrated by the grounded outlet

FIGURE A

LENGTH OF

CONDUCTOR

0-25 FEET

26-50 FEET

51-100 FEET

WIRE SIZES REQUIRED

(AMERICAN WIRE GAUGE)

110V LINES

NO.16
NO.14
NO.12

FIGURE C

FIGURE B

box in Fig.A. No adaptor is available or should be used for
120V operation.

EXTENSION CORDS

The use of any extension cord will cause some loss of power. Use
the following table to determine the minimum wire size (A.W.G-
American Wire Gauge) extension cord. Use only 3-wire 
extension cords which have 3-prong grounding type plugs and
3-hole receptacles which accept the tool’s plug.

For circuits that are further away from the electrical circuit box, the
wire size must be increased proportionately in order to deliver
ample voltage to the bandsaw motor. Refer to Fig.C for wire
length and size.

PROPERLY GROUNDED OUTLET

CURRENT CARRYING
PRONGS

GROUNDING
PRONG

PROPERLY GROUNDED OUTLET

CURRENT CARRYING PRONGS

GROUNDING PRONG

Содержание KC-2102C

Страница 1: ...INSTRUCTION MANUAL MODEL KC 2102C KC 2102FXR COPYRIGHT 2002 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC 21 WOOD BANDSAW KC 2102FXR SEE PAGE 9...

Страница 2: ...defects due directly or indirectly to misuse abuse negligence or accidents repairs or alterations and lack of maintenance KING CANADA shall in no event be liable for death injuries to persons or prope...

Страница 3: ...rings watch because they could get caught in moving parts Non slip footwear is recommended Wear protective hair covering to contain long hair Roll up long sleeves above the elbows 12 ALWAYS WEAR SAFE...

Страница 4: ...ER WHEEL COVER LOWER DRIVE WHEEL MOTOR PULLEY LEVER ROD QUICK CHANGE SAW BLADE SYSTEM POSITIVE KNOB LOCK KNOB MOTOR REAR OF BAND SAW FRONT OF BAND SAW AVAILABLE KING CANADA BLADES FOR YOUR BANDSAW Mod...

Страница 5: ...g B WARNING DO NOT USE A TWO PRONG ADAPTOR FOR THEY ARE NOT IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES NEVER USE IN CANADA 120V OPERATION If 120V single phase operation is desired the following ins...

Страница 6: ...B Fig 2 3 Place a square A Fig 3 on the table and against the blade B Fig 3 to see if the table is 90 degrees to the blade 4 If it is not 90 degrees use the micro adjustment knob to position table at...

Страница 7: ...ndle and adjust the positive knob B Fig 5 9 Replace the table insert and table pin 10 Adjust the blade tension and blade tracking if the blade width is different ADJUSTING UPPER LOWER BLADE GUIDE ASSE...

Страница 8: ...cted to a dust collector This will avoid a dusty and undesired work environment There are two 4 dust ports A Fig 9 4 Dust Collection hoses must be attached to the dust ports using 4 steel clamps and t...

Страница 9: ...e most updated parts diagram and parts list 2 YEAR LIMITED WARRANTY FOR KING INDUSTRIAL MACHINERY PROOF OF PURCHASE Please keep your dated proof of purchase for warranty and servicing purposes REPLACE...

Отзывы: