electrical inFormation
warning!
ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE BANDSAW DISCONNECTED FROM THE POWER SOURCE.
FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!
general inFormation- 220v single phase operation
This 17” wood/metal bandsaw comes with a 2 HP 220V 3 Phase motor.
A single phase (1 phase) inverter allows this machine to be run on 220V
1 phase input power.
electrical supply
warning:
YOUR BANDSAW MUST BE CONNECTED TO A 220V, 1
PHASE ELECTRICAL SUPPLY. FAILURE TO CONNECT IN THIS WAY
CAN RESULT IN INJURY FROM SHOCK OR FIRE.
This bandsaw is intended for use on an electrical circuit that has an outlet
and a plug which looks like the one illustrated in Fig.A.
warning:
DO NOT USE A TWO-PRONG ADAPTOR FOR THEY ARE
NOT IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES.
NEVER USE IN CANADA.
grounding
Your bandsaw must be properly grounded. Not all outlets are properly
grounded. If you are not sure if your outlet is properly grounded, have it
checked by a qualified electrician. If it should malfunction or breakdown,
grounding provides a path of least resistance for electric current, to re-
duce the risk of electric shock. This bandsaw is equipped with a cord
having an equipment-grounding conductor and grounding plug. The plug
must be plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
warning:
TO MAINTAIN PROPER GROUNDING OF YOUR
BANDSAW, DO NOT REMOVE OR ALTER THE GROUNDING PRONG
IN ANY MANNER.
warning:
IF NOT PROPERLY GROUNDED, THIS BANDSAW CAN
CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN USED IN
DAMP LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER
CORD IS WORN OR DAMAGED IN ANY WAY, HAVE IT REPLACED
IMMEDIATELY.
eXtension cords
The use of an extension cord is generally not recommended for 220V
operation. The use of any extension cord will cause some loss of power.
Use the table (Fig.B) to determine the minimum wire size (A.W.G-Amer-
ican Wire Gauge) extension cord needed. Use only 3-wire extension
cords which have 3-prong grounding type plugs and 3-hole receptacles
which accept the tool’s plug.
For circuits that are further away from the electrical circuit box, the wire
size must be increased proportionately in order to deliver ample voltage
to the bandsaw motor. Refer to Fig.B for wire length and size.
Figure b
Figure a
properly grounded outlet
current carrying prongs
grounding prong
warning!
220v 3 pHase motor- input power: 220v 1 pHase power supply
LENGTH OF
EXTENSION CORD
0-25 FEET
26-50 FEET
51-100 FEET
WIRE SIZES REQUIRED
(AMERICAN WIRE GAUGE)
220v lines only
NO.14
NO.12
NO.10
Содержание KC-1700WM-VS