background image

operatioN coNtrols continued...

DraiN ValVe (a) fig.7.

The drain valve is located at the base of the air tank

and is used to drain condensation at the end of each use. Turn drain valve 

counterclockwise to open (no pressure build-up) or clockwise to close it (permits

pressure build-up).

preparation for use: 

1. Before attaching an air hose or accessories, make sure the On/Off switch is

set to “OFF” and the air regulator is closed (completely turned counterclock-

wise). 

2. Connect an air hose having a male fitting (B) Fig.8 (not supplied) into the 

female quick connect coupler (A). Pull the female quick connect coupler ring

backwards and push the male fitting into the coupler until it is secured, 

release the female quick connect coupler ring. Attach optional air tool or 

accessory to a female quick connect coupler installed at the other end of the

air hose. To prevent air leaks, it is recommended to install Teflon Tape (not

supplied) on the threads at both ends of the hose fittings.

WarNiNg

: Too much air pressure causes a hazardous risk of bursting. Check

the manufacturer's maximum pressure rating for air tools and accessories. The

regulator outlet pressure must never exceed the maximum pressure rating of

the tool being used.

3. Turn the switch to the On position and allow tank pressure to build. Motor will

stop when tank pressure reaches “cut-out” pressure.

4. Open the regulator by turning it clockwise. Adjust the regulator to the correct

pressure setting. The compressor is ready for use.

after use: 

1. Set the switch to Off. Disconnect power cord from power source.

2. Turn the regulator counterclockwise to set the outlet pressure to zero.

3. Disconnect the air tool or accessory.

4. Pull ring on safety valve (C) Fig.4, allowing air to bleed from the tank until tank pressure is approximately 20 PSI. Release safety valve ring.

5. Drain water from air tank. Turn drain valve (A) Fig.7, counterclockwise to open.

WarNiNg!: Water Will coNDeNse iN tHe air taNK. 

moisture in compressed air

When humidity is high or when the compressor is in continuous use for an extended period of time, this moisture will collect in the air tank. When

using a spray gun or sandblast gun, this water will be carried from the tank through the hose and out of the gun as droplets mixed with the spray

material. This will cause water spots in a paint job, especially when spraying other than water based paint. If sandblasting, it will cause the

material to cake and clog the gun, rendering it ineffective. 

DraiN Water from air taNK oN a regular basis 

or an optional air control

unit with dirt and moisture removal should be used to prevent these undesireable results.

Note:

If drain valve is plugged, pull ring on safety valve (C) Fig.4, and hold until all air pressure has been released. The drain valve can then be

removed, cleaned, and reinstalled.

6. After the water has been completely drained, turn drain valve (A) Fig.7 clockwise to close. The air compressor can now be stored. 

Keep tool cleaN

Periodically blow out all air passages with dry compressed air. Clean all plastic parts with a soft damp cloth. NEVER use solvents to clean plastic

parts. They could possibly dissolve or otherwise damage the material.

cautioN

: Wear safety glasses while using compressed air.

figure 7

operatioNal guiDeliNes

& maiNteNaNce

5

figure 8

Содержание KC-1410A

Страница 1: ...017 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC ultra quiet oil free air compressor SILENT SERIES SILENT SERIES SÉRIE SILENCIEUX SÉRIE SILENCIEUX SILENT SERIES SILENT SERIES SÉRIE SILENCIEUX SÉRIE SILENCIEUX SILENT SERIES SÉRIE SILENCIEUX 09 2017 ...

Страница 2: ...ized service center alterations and lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To take advantage of this limited warranty return the product at your expense together with your dated proof of purshase to an authorized King Canada service center Contact y...

Страница 3: ...ver make adjustments or parts substitutions to alter the factory set operating pressures For essential control of air pressure you must install a pressure regulator and pressure gauge to the air supply system risK of burNs WHat caN HappeN Touching exposed metal such as the compressor head or outlet tubes can result in serious burns HoW to preVeNt it Never touch any exposed metal parts on compresso...

Страница 4: ... cut off is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WarNiNg TO MAINTAIN PROPER GROUNDING DO NOT REMOVE OR ALTER THE GROUNDING PRONG IN ANY MANNER 120V operatioN As received from the factory your compressor is ready to ...

Страница 5: ...me safetY ValVe c fig 4 If the pressure switch does not shut off the air compressor at its cutout pressure setting the safety valve will protect against high pressure by popping out at its factory set pressure slightly higher than the pressure switch cut out setting WarNiNg If the safety valve does not work properly over pressurization may occur causing air tank rupture or an explosion Daily pull ...

Страница 6: ...rd from power source 2 Turn the regulator counterclockwise to set the outlet pressure to zero 3 Disconnect the air tool or accessory 4 Pull ring on safety valve C Fig 4 allowing air to bleed from the tank until tank pressure is approximately 20 PSI Release safety valve ring 5 Drain water from air tank Turn drain valve A Fig 7 counterclockwise to open WarNiNg Water Will coNDeNse iN tHe air taNK moi...

Страница 7: ...he tank Humidity too high correctiVe actioN Check for cause of blown fuse breaker and replace Check wiring connections Turn compressor off wait until total cool down before restarting Check valve manually by pulling on ring If condition persists replace valve Replace check valve Check for proper adjustment and if problem persists replace pressure switch Tighten drain valve Check connections for le...

Отзывы: