If with the automation closed a command is given via radio or with the “STR” input or the START pushbutton present on the board, the 

control unit:

- makes a one-second fixed pre-flash

- activates the motor at the speed set with the FOR trimmer.

- the opening stops with the intervention of the limit stop, the obstacle detection device or when the manoeuvre time expires, or with a 

radio or manual command. In this latter case, the control unit disables the automatic closing and to restart the manoeuvre another 

command must be given.

If the automation is completely open, when the pause time has elapsed the closing manoeuvre starts. The control unit:

- makes a one-second fixed pre-flash.

- activates the motor for one second at reduced speed and then at the speed set with the FOR trimmer.

- the closing stops with the intervention of the limit stop or the detection of an obstacle or when the manoeuvre time has expired.

MAN PRESENT MODE

Switch the dip-switch 3 to the OFF position and dip-switch 2 to the OFF position.

Keep the START pushbutton on the board pressed, the control unit commands an opening until the limit stop is reached in opening or the pushbutton is 

released.

Keep the P2/RAD pushbutton on the board pressed, the control unit commands the closure until the limit stop is reached or the pushbutton is released.

The radio command has no effect. When the control unit is in this mode, it is not possible to enter the radio code programming.

FLASHING LIGHT

The control unit is fitted with two output terminals (LAMP + and -) to control a 12 or 24 VDC low voltage flashing light. The voltage can be selected using 

the jumper above the terminal of the flashing light.

The flashing light flashes 1 second before every opening manoeuvre and 1 second before a closing manoeuvre.

If DIP 4 is in the OFF position the power supplied to the flashing light is DC, therefore a low consumption flashing light with a built in oscillating circuit must 

be connected to the terminal (FEBOLIX 12VDC 2W type). 

If the DIP 4 is the ON position the power supplied to the flashing light is alternating and therefore a normal lamp without an oscillating circuit can be 

connected (12 or 24VDC, Max 10W). 

SLOW-DOWN

With the slow-down function, the door applies a reduced force before reaching the limit stop. The reduced speed is about one third of the normal working 

speed. With the professional learning, the starting points of the slow-down, in both opening and closing, can be selected at will, or else the slow-down can 

be disabled.

COURTESY LIGHT

The contact provided by the control unit allows 24VAC Max 20W lamps to be controlled. The switching on command of the courtesy light is given before 

every manoeuvre and the contact remains activated for about 120 seconds after opening.

To switch on the courtesy light with a radio channel that is different from that for the door opening

BACK-UP BATTERY

The control unit is equipped with a 24VDC battery charger therefore a 24V battery or two 12V batteries in series must be used.

A maximum of 5 manoeuvres are possible with the 24V 1.2Ah back-up battery. The control unit can manage batteries up to7Ah (20-30 complete 

manoeuvres).

STOP LOGIC (STP INPUT)

The activation of the STOP input provokes the block all the functions.

To restart the cycle the STOP must be deactivated and another command must be given.

SIGNALLING LED

SET yellow LED:

- when turned on, it flashes for 5 seconds to indicate that simplified or professional learning mode can be entered

- lights up with a fixed light during simplified or professional learning procedure

- it is OFF during normal operation of the control unit

RAD red LED:

- flashes briefly when a 433 MHz line Multipass radio code is received

- lights up with a fixed light while the radio codes are being memorised

- flashes rapidly when the control unit is switched on if the radio code memory is defective

- flashes rapidly during the cancellation of radio codes

- flashes faster when there is an attempt to enter new radio codes and the memory is full

- it is OFF during normal operation of the control unit while waiting to receive commands via radio

ST status red LED:

- lights up when the door is closed

- flashes rapidly when the control unit is blocked (e.g. safeties test not passed)

- flashes when the control unit is open or during opening or closing

7

Содержание Star D 500

Страница 1: ...ore installing thoroughly read this manual that is an integral part of this Kit Antoniolli Mario C s a s declines any responsibility in the event current standards in the country of installation are n...

Страница 2: ...DIP Safeties test enabled with DIP Flash microprocessor re programmable on board via serial interface Simplified and professional learning procedure Built to European reference Directive Standards R T...

Страница 3: ...to obtain an operator movement that is slower and requires less force After having adjusted the force the learning procedure must be repea ted PHOTOCELLS STOP OPEN STEP STEP MOTOR 24Vdc Max 100W 230 V...

Страница 4: ...motor turns in reverse invert wires and start procedure again from RESET Adjust trimmers if necessary ATTENTION A trimmer variation FOR speed requires the repetition of the learning procedure from RES...

Страница 5: ...ning Adjust trimmers if necessary ATTENTION A trimmer variation FOR speed requires the repetition of the learning procedure from RESET With only encoder present terminate manoeuvre by pressing P1 SET...

Страница 6: ...memory During saving the red LED flashes slowly When it is finished the red LED returns to the fixed light status to signal that a new remote control can be entered Memorise all the transmitters by ma...

Страница 7: ...educed speed Softstart and then at the speed set with the FOR trimmer if a command is received during closure the control unit commands the complete re opening the closure terminates when the limit st...

Страница 8: ...shing light is alternating and therefore a normal lamp without an oscillating circuit can be connected 12 or 24VDC Max 10W SLOW DOWN With the slow down function the door applies a reduced force before...

Страница 9: ...nstallation maintenance repairs and cleaning operations must be documented This documentation must be preserved by the user and made available to the personnel responsible for the control WARNINGS FOR...

Отзывы: