WATTAGE SELECTION

The heater is factory wired to 1500 Watts at 
120 Volts. To reduce wattage unplug an insu-
lated push on terminal per color coding below.  
Wrap with electrical tape to prevent  possibility 
of electrical contact with other parts.

A

C

D Common

 750

END VIEW OF ELEMENT

B

 

  500

A

 - 750 W  

 B 

- 500 W   

C

 - 250 W

D

 - Common Leg of Power Supply

250

B

WIRE COLOR CODING

A  Orange

  Disconnects the 1000 Watt element

B  Blue 

      Disconnects the 750 Watt element

C  Yellow  

 Disconnects the 500 Watt element

D  Black 

    DO NOT DISCONNECT (Common)

WATTAGE SELECTION

The heater is factory wired to 2250 Watts 
at 208/240 Volts. To reduce wattage unplug  
an insulated push on terminal per the color 
coding below. Wrap with electrical tape to 
prevent the possibility of electrical contact 
with other parts.

PIC-A-WATT

SLP LIMIT

Built-in Thermotat

(Optional)

 Steel Sheath Element

2022  

208V  2250W 

2422  

240V  2250W

GRAY

GRAY

L2

 Push on Terminal

208V 
240V

MOTOR

Field Connections

GREEN

Ground

D

BLUE

BLACK 

BLACK

ORANGE

YELLOW

L1

L2

1000 WATT

A

B

C

750 WATT

500  WATT

BLACK 

A

C

D Common

 1000

END VIEW OF ELEMENT

 

750

500

A

 - 1000 W  

 B 

- 750 W   

C

 - 500 W

D

 - Common Leg of Power Supply

SLP 

Limit

Depth - 

½

"

Height - 7

½

"

Width - 13

½

"

FAN-FORCED HEATERS:

Clearances for Safe Operation

(SL Series only approved for 

zero clearance to 

fl

 oor)

WIRE COLOR CODING

A  Orange

  Disconnects the 750 Watt element

B  Blue 

      Disconnects the 500 Watt element

C  Yellow  

 Disconnects the 250 Watt element

D  Black 

    DO NOT DISCONNECT (Common)

PIC-A-WATT

BLUE

Built-in Thermotat

(Optional)

 Steel Sheath Element

1215  

120V 1500W

YELLOW

L2

 Push on Terminal

120 V

MOTOR

Field Connections

GREEN

Ground

D

SLP LIMIT

BLACK 

WHITE

GRAY

ORANGE

GRAY

L1

L2

A

B

C

BLACK 

750 WATT

500 WATT

250 WATT

NOTE: SL Slimline Series only is zero clearance to floor

CAUTION

The heater

should not

be covered
or blocked

in any manner.

EXPLODED VIEW

WIRING DIAGRAM

INSTALLATION INSTRUCTIONS

SAVE THESE INSTRUCTIONS

KING ELECTRICAL MFG. COMPANY  ·  9131 10TH AVENUE SOUTH  ·  SEATTLE, WA  98108  ·  PH: 206.762.0400  ·  FAX: 206.763.7738  ·  www.king-electric.com

INSTALLATION

2

Following are installation guidelines:

  • Disconnect power at main panel.

  • Make certain all wiring is in accordance with any/all local codes. 

 

  • Ensure units are properly grounded.

  • Heater voltage rating should be the same as supply load. 

1.  Remove two screws on front grille. Remove grille. Loosen mounting screw.  

   Remove fan heater assembly.

2. Remove a 7/8" knockout. Thread supply wire into wallbox. Use an approved  

  strain relief bushing to prevent cha

fi

 ng of supply wires through the opening in  

  wallbox.

3. Install wall can a minimum of 6" from vertical sidewalls and 4" above 

fl

 oor   

  (zero clearance to 

fl

 oor for SL series). 

The front edge of wall can must be  

 

½

" beyond finished wall.

 

4. Secure wallbox to the 2x4 studs using the two (2) holes on each side of    

  wallbox. Secure twist lock to wall stud on opposite side.   

5. Select heater wattage

 (see diagram)

King recommends the installer indicate  

  the selected heater wattage by circling the wattage listed on the nameplate.  

  To prevent the heater from being rewired to a higher wattage, cut the push- 

  on 

¼

" female terminal off the disconnected wire (orange, blue or yellow). 

  Tape all exposed wires. By disabling the heater in this manner there is no    

  need to size the circuit beyond the actual connected load. (For future 

fl

 exibility  

  to increase wattage, size circuit for the maximum 2250 Watts per heater for  

  208/240 Volt , 1500 Watts per heater for 120 Volt).

6. Reinstall heater assembly at top of wallbox with mounting screw.  

 

  Connect supply and ground wires.

 (see diagram)

7. Reinstall grille securely with screws provided.

 

For proper air circulation, the  

  top louver in grille must open into and between wall can and top of heater.

FIELD WIRING – 120/277 VOLT:

1. Connect power supply L1 (white neutral wire) to white heater wire.

2. Connect power supply L2 (black hot lead) to black heater wire.

3. Connect groundwire to green wire on wall can. 

FIELD WIRING – 208/240 VOLT:

1. Connect power supply L1 (hot lead) to a black heater wire.

2. Connect power supply L2 (hot lead) to a black heater wire.

3. Connect groundwire to green wire on wall can.

NOTE:

 The two black leads on the heater can be connected to either hot lead. 

There is no polarity. The 208/240 Volt heater does not require a neutral wire from 

the power panel.

paw-dec-sl.indd : 8/09

This heater includes a manual reset SLP thermal protector with a 
self-hold feature. If the heater shuts off in the on position and the room 
temperature is below the highest thermostat setting, immediately discon-
nect the power to the heater at the circuit breaker. Inspect for any objects 
on or adjacent to the heater that may cause high temperatures. After 

inspecting the heater, keep the power to the heater off for 10 minutes to reset the SLP 
thermal protector. If the SLP thermal protector shuts the heater off again, immediately turn 
the heater off at the circuit breaker and inspect the heater for possible fan motor failure or 
dirt and lint on the heating element. Repeat the starting procedure.

Содержание 1215

Страница 1: ...le free performance Each year the heater should be checked and cleaned for lint and or dust accumulation King recommends using a soft bristle brush and vacuum to knock off contaminates The motor is permanently lubricated and requires no oiling PAW Wall Heaters and SL Slim Line Wall Heaters carry a five 5 year warranty on the elements and a two 2 year warranty on components from date of installatio...

Страница 2: ...e two screws on front grille Remove grille Loosen mounting screw Remove fan heater assembly 2 Remove a 7 8 knockout Thread supply wire into wallbox Use an approved strain relief bushing to prevent chafing of supply wires through the opening in wallbox 3 Install wall can a minimum of 6 from vertical sidewalls and 4 above floor zero clearance to floor for SL series The front edge of wall can must be...

Страница 3: ...ctronic ES230 or ESP230 models If in the future you decide to remodel or add rooms to your home you won t have to worry about the size of your heating system With electric heat you can add to the heating system in large or small increments Q Will the room heat up faster if I put the thermostat on 90 degrees when I get home A No The thermostat is just an on off switch that is temperature sensitive ...

Страница 4: ...ome out of balance if deformed The useful life on a PAW DEC SL Series Heater depends on the amount of use environment and how often it is cleaned and maintained Heaters operated beyond their useful life are more prone to problems For example when a motor slows down due to wear or lack of cleaning it reduces the CFM and can cause the heater to overheat tripping the limit control The limit will cycl...

Страница 5: ...PAW DEC SL indd 8 09 FAN FORCED HEATERS Clearances for Safe Operation In built thermostat may be installed by customer or factory Front Grille Wall Can Grille Dimensions Depth 3 4 Height 7 1 2 Width 13 7 8 Fan blower heating element interior assembly 6 1 4 x 12 5 8 Wall opening 12 5 8 6 1 4 Top first louver in the grille must be open into and between wall can and top of heater interior for proper ...

Отзывы: