King Canada KCG-4200G Скачать руководство пользователя страница 6

WARNING! To prevent permanent damage to generator or any appliances, you MUST check oil level, fuel level, air cleaner filter and

unplug any load from the generator before starting.

ASSEMBLY

Remove all the contents from the carton and proceed to the following assembly steps;

Pivot handle

Install the pivot handle (A) Fig.1A to the left side of the frame using 2 hex. bolts and hex.

nuts.

Wheels and Frame Supports

To install the wheels (B) Fig.1A to the right end of the frame, install the wheel shafts to the

front and back of the frame first and secure them in place using hex. nuts. Slide each wheel

onto the wheel shafts and secure the wheels by inserting a cotter pin (C) into the end of

the wheel shafts, then seperate and bend the cotter pin outwards. Now that the wheels

are installed, the last assembly step is to install the frame supports (D) to the frame using

hex. bolts and hex. nuts.

PRE-START ChECK

OIL LEVEL

WARNING! This generator has been shipped from the factory without oil or very little

oil in the crankcase. Operating the unit without the correct amount of oil can damage

the engine. Oil crankcase capacity: 0.6 litres.

Always check the oil level before starting the generator, make sure the genarator is

on a level surface. To check oil level;

1) Turn the oil gauge dipstick (A) Fig.1B counterclockwise, remove it and clean it with a

clean cloth.

2) Fully reinsert the oil gauge dipstick and pull it out to check the oil level.

3) If the oil level is halfway up the dipstick or below, refill with SAE 10W30 oil through the

dipstick hole until the oil level reaches 3/4 up the dipstick or until it reaches the bottom

lip of the dipstick hole as shown in illustration below.

4) Reposition the oil gauge dipstick and tighten it by turning clockwise.

FUEL LEVEL

WARNING! Make sure there is enough fuel in the fuel tank before operating.

1) Check the fuel level indicator window (A) Fig.2, if the orange float gauge is all the way up, it is not necessary to add fuel. If you do not see

or hardly see the orange float gauge, it is necessary to add fuel.

2) If it is necessary to add fuel, first make sure the engine is OFF, then open the fuel cap (B) Fig.2 by turning it counterclockwise.

3) Make sure the fuel filter cup (C) is positioned inside the tank opening before refueling.

4) When refueling, keep in mind all safety precautions and make sure to add enough fuel based on usage. A full tank will give you 8-9 hours

of operation. Use clean unleaded gasoline with a minimum of 87 octane. Do not mix oil with gasoline. Fuel tank capacity: 15 Litres.

ASSEMBLY & PRE-START ChECK

Figure 1B

Figure 2

Figure 1A

Содержание KCG-4200G

Страница 1: ...STRUCTION MANUAL COPYRIGHT 2014 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL KCG 4200G Read this manual Do not attempt to operate this generator until you have read and understood the safety operation and maintenance instructions 07 2014 ...

Страница 2: ...iability caused by shipping improper handling improper installation improper maintenance improper modification or the use of accessories and or attachments not specifically recommended Repairs necessary because of operator abuse or negligence or the failure to install operate maintain and store the product according to the instructions in the owner s manual Damage caused by cold heat rain excessiv...

Страница 3: ...ock will occur Be sure to ground earth the generator ELECTRICAL CONNECTION NOTES Avoid connecting the generator to commercial power outlet Avoid connecting the generator in parallel with any other generator WARNING The engine muffler will be very hot after use avoid touch ing the engine or muffler while they are still hot FUEL Make sure there is sufficient fuel in the tank GROUNDING Make sure to g...

Страница 4: ...ient such as storage rooms or garages can interfere with its proper ventilation fea tures causing overheating and possible ignition of the materials or build ings Operate generator in a clean dry well ventilated area a minimum of four feet from any building object or wall DO NOT OPERATE UNIT IN DOORS OR IN ANY CONFINED AREA RISK OF BREAThING INhALATION hAZARD Operate generator in clean dry well ve...

Страница 5: ...ning indicator light This generator detects and shuts off automatically when the oil level is too low In case of an auto shut off and the indicator light is ON check oil level with dipstick 12 and fill to recommended level with SAE 10W30 engine oil 15 Power ON switch This switch must be switched to ON before pulling recoil starter 16 Transport Pivot handle 17 Spark plug cover The spark plug must b...

Страница 6: ...sure the genarator is on a level surface To check oil level 1 Turn the oil gauge dipstick A Fig 1B counterclockwise remove it and clean it with a clean cloth 2 Fully reinsert the oil gauge dipstick and pull it out to check the oil level 3 If the oil level is halfway up the dipstick or below refill with SAE 10W30 oil through the dipstick hole until the oil level reaches 3 4 up the dipstick or until...

Страница 7: ...pike into the earth Your local electrical company or certified electrician should be able to help you with this information See Fig 4 STARTING YOUR GENERATOR WARNING Do not adjust or attempt maintenance of engine without consulting an authorized service center Never run engine indoors or in enclosed poor ventilated areas engine exhaust contains carbon monoxide an odorless and deadly gas Make sure ...

Страница 8: ...hould be the last equipment connected to the generator Plug voltage sensitive appliances such as TV s VCR s microwaves ovens computers and cordless telephones into a UL CSA listed voltage surge protector then connect the UL CSA listed voltage surge protector to the generator Overloading the generator will cause power fluctuations and can damage equipment and appliances King Canada will not be resp...

Страница 9: ...age Requirement Chart below This is only a guideline each ap pliance or electrical device needs to be checked for its specific operat ing load DETERMINING WATTAGE REqUIREMENTS Note Volts X Amps Watts Example 120V X 10 Amps 1200 Watts Before operating this generator list all of the appliances and or tools that are going to operate at the same time Then determine the starting wattage requirements an...

Страница 10: ...order Fuel Filter Maintenance In order to clean the fuel filter inside the fuel cock it is necessary to drain all gasoline from the tank and the carburetor see section Generator Storage below for complete instructions 1 Once the tank and carburetor are drained of all gasoline disconnect the fuel hose A Fig 11 from the fuel cock and then dismantle the fuel cock nut B from the tank 2 Remove the fuel...

Страница 11: ... 1 Generator overloaded 2 Insufficient ventilation 1 Electrical short in connected item 2 Overloaded CORRECTION 1 Add fuel or oil 2 Turn to ON position 3 Replace spark plug 4 Adjust choke accordingly 5 Open fuel shut off valve 6 Remove load from unit 7 Attach wire to spark plug 1 Have Service Center replace 2 Reset breaker 3 Have Service Center replace capacitor 4 Repair or replace cord 1 Reduce l...