King Canada KCG-2000i Скачать руководство пользователя страница 9

WATTAGE CALCULATIONS

WATTAGE CALCULATIONS

IMPORTANT! Never exceed the rated capacity of your generator.
Serious damage to the generator or appliance could result from an
overload.

1) “Starting” and “Running” wattage requirements should always be

calculated when matching a generators wattage capacity to the
appliance or tool.

2) There are two types of electrical appliances that can be powered by

your generator;

a) Items such as radios, light bulbs, televison sets, and microwaves

have a “resistive load”. Starting wattage and running wattage are
the same.

b) Items such as refrigerators, air compressors, washer, dryer and

hand tools that use an electrical motor have an “inductive load”.

Inductive load appliances and tools require approx. 2 to 3
times the listed wattage for “starting” the equipment.

This

initial load only lasts for a few seconds on start-up but is important
when figuring your total wattage to be used.

Always start your largest electric motor first, and then plug in other
items, one at a time.

Wattage Requirement Chart below

- This is only a guideline, each

appliance or electrical device needs to be checked for its specific
operating load.

DETERMINING WATTAGE REQUIREMENTS

Note: Volts X Amps = Watts
Example: 120V X 16.7 Amps = 2000 Watts

Before operating this generator, list all of the appliances and/or tools
that are going to operate at the same time. (Then determine the
starting wattage requirements and the running wattage requirements
by following the example below;

1) Add the total amount of the running wattage of all appliances and/or
tools that will be operated at the same time.
Example 1A:
Lights = 100 Watts (Running)
Television = 135 Watts (Running)

TOTAL = 235 Watts (Running)

2) Next add the total amount of the starting wattage of any appliances
and/or tools that will start and stop during operation.
Example 1B: 
Small refrigerator 500 Watts (Running) 2000 Watts (Starting)

TOTAL = 500 Watts (Running) 2000 Watts (Starting)

3) The running wattage of examples 1A & 1B totals 735 watts. The
starting wattage of the small refrigerator is 2000 watts which is 1265
watts more than the running watts. Take this difference of 1265
starting watts from the refrigerator and add to the total running watts of
735. Therefore:

1265 Starting Watts + 735 Running Watts = 2000 Total Watts
The generator required to operate the items in example 1A & 1B
must have a minimum capacity of at least 2000 starting watts.

Содержание KCG-2000i

Страница 1: ...R INSTRUCTION MANUAL COPYRIGHT 2009 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL KCG 2000i Read this manual Do not attempt to operate this generator until you have read and understood the safety...

Страница 2: ...THIS WARRANTY IS NOT TRANSFERABLE AND DOES NOT COVER Damage or liability caused by shipping improper handling improper installation improper maintenance improper modification or the use of accessories...

Страница 3: ...ck will occur Be sure to ground earth the generator ELECTRICAL CONNECTION NOTES Avoid connecting the generator to commercial power outlet Avoid connecting the generator in parallel with any other gene...

Страница 4: ...on of the materials or buildings Operate generator in a clean dry well ventilated area a minimum of four feet from any building object or wall DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AREA RISK...

Страница 5: ...power 12V DC items 11 10 Amp DC Reset Button Resets the 12V DC outlet 12 Grounding terminal This generator must be grounded see grounding instructions 13 Duplex AC 120V outlets Plug up to 2 120V appl...

Страница 6: ...ing it counterclockwise 2 Make sure the fuel filter cup B is positioned inside the tank opening before refueling 3 When refueling keep in mind all safety precautions and make sure to add enough fuel b...

Страница 7: ...e indoors or in enclosed poor ventilated areas engine exhaust contains carbon monoxide an odorless and deadly gas Make sure all electrical appliances are unplugged before attempting to start generator...

Страница 8: ...8 For normal 120V operation plug your appliance or power bar into one of the duplex 120V receptacles A Fig 8 12V DC OUTLET B FIG 8 Main use charging 12V automotive batteries IMPORTANT Allow generator...

Страница 9: ...needs to be checked for its specific operating load DETERMINING WATTAGE REQUIREMENTS Note Volts X Amps Watts Example 120V X 16 7 Amps 2000 Watts Before operating this generator list all of the applian...

Страница 10: ...bon sediment is excessive replace the spark plug 4 Measure the electrodes clearance See Fig 11 The spark plug electrode clearance should be between 0 7 0 8mm If the clearance exceeds 0 8mm replace the...

Страница 11: ...NERATOR STORAGE If you plan on storing your generator for an extended period of time the following steps should be followed 1 Add fuel stabilizer to fuel tank to minimize the formation of fuel gum dep...

Отзывы: