GETTING TO KNOW YOUR 

DIGITAL INVERTER GENERATOR

1. Fuel cap. 

Make sure the fuel cap is always screwed on tightly. Use

unleaded gasoline only! 7 Liter capacity.

2. Spark plug access cover.

Periodically the spark plug must be

checked and maintained, see maintenance section.

3. 20 Amp AC Breaker.

The AC breaker turns off automatically when

the load exceeds the generator rated output. Reduce the load to
within specified generator rated output if AC breaker turns off. 

4. Overload indicator light. 

Lights up when generator is overloaded.

5. Power indicator light. 

Lights up when generator is ready to use.

6. Low oil warning indicator light. 

Lights up when oil level is too

low. This generator detects and shuts off automatically when the oil
level is too low. In case of an auto shut-off and the indicator light is
ON, check oil level with dipstick (#19) and fill to recommended level
with SAE 10W30 engine oil.

7. Economical mode switch.

Adjusts the engine speed based on

connected load, for improved fuel consumption.

8. Engine switch.

Must be placed to the “On” position before pulling

the recoil starter handle.

9. Recoil starter. 

Starts the engine.

10. DC Outlet.

Use to power 12V DC items.

11. 10 Amp DC Reset Button.

Resets the 12V DC outlet.

12. Grounding terminal. 

This generator must be grounded, see

grounding instructions.

13. Duplex AC 120V outlets. 

Plug up to 2-120V appliances or a power

bar, make sure the amps requirement does not exceed max amps
(17 amps) or else the AC breaker will automatically shut-off the
power output.

14. Carburetor throttle lever (choke). 

Once the engine is started, it is

necessary to gradually turn the carburetor throttle lever to the “Off”
position, see instructions futher in this manual.

15. Fuel Shut-off Valve. 

Regulates the flow of fuel to the engine. The

fuel shut-off valve must be fully opened before starting the engine.

16. Fuel Pump Primer.

To start, press fuel pump engine primer 3-5

times. For initial season start or dry starts, prime engine 30-50
times.

17. Caburetor.
18. Air cleaner filter/cover.

Periodically the air cleaner filter must be

checked and maintained, see maintenance section.

19. Oil gauge dipstick. 

Check the oil level using this oil gauge

dipstick.

MODEL 

KCG-2000i

Peak Wattage (starting)

2100W

Running Wattage 

2000W

AC Outputs

1(2x 120V/16.7A)

DC Output

12V (8.3A)

Engine (OHV)

4.5 HP

No load speed

5,400 RPM

Displacement (cc)

125

Fuel

Unleaded Gasoline

Fuel tank (L)

7

Oil capacity (L)

0.45

Run time

5-6 hours

Noise level

57 dB(A)

Dimensions (LxWxH)

21-1/2” x 11-1/2” x 20”

Weight

58 lbs

Содержание KCG-2000i

Страница 1: ...R INSTRUCTION MANUAL COPYRIGHT 2009 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL KCG 2000i Read this manual Do not attempt to operate this generator until you have read and understood the safety...

Страница 2: ...THIS WARRANTY IS NOT TRANSFERABLE AND DOES NOT COVER Damage or liability caused by shipping improper handling improper installation improper maintenance improper modification or the use of accessories...

Страница 3: ...ck will occur Be sure to ground earth the generator ELECTRICAL CONNECTION NOTES Avoid connecting the generator to commercial power outlet Avoid connecting the generator in parallel with any other gene...

Страница 4: ...on of the materials or buildings Operate generator in a clean dry well ventilated area a minimum of four feet from any building object or wall DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AREA RISK...

Страница 5: ...power 12V DC items 11 10 Amp DC Reset Button Resets the 12V DC outlet 12 Grounding terminal This generator must be grounded see grounding instructions 13 Duplex AC 120V outlets Plug up to 2 120V appl...

Страница 6: ...ing it counterclockwise 2 Make sure the fuel filter cup B is positioned inside the tank opening before refueling 3 When refueling keep in mind all safety precautions and make sure to add enough fuel b...

Страница 7: ...e indoors or in enclosed poor ventilated areas engine exhaust contains carbon monoxide an odorless and deadly gas Make sure all electrical appliances are unplugged before attempting to start generator...

Страница 8: ...8 For normal 120V operation plug your appliance or power bar into one of the duplex 120V receptacles A Fig 8 12V DC OUTLET B FIG 8 Main use charging 12V automotive batteries IMPORTANT Allow generator...

Страница 9: ...needs to be checked for its specific operating load DETERMINING WATTAGE REQUIREMENTS Note Volts X Amps Watts Example 120V X 16 7 Amps 2000 Watts Before operating this generator list all of the applian...

Страница 10: ...bon sediment is excessive replace the spark plug 4 Measure the electrodes clearance See Fig 11 The spark plug electrode clearance should be between 0 7 0 8mm If the clearance exceeds 0 8mm replace the...

Страница 11: ...NERATOR STORAGE If you plan on storing your generator for an extended period of time the following steps should be followed 1 Add fuel stabilizer to fuel tank to minimize the formation of fuel gum dep...

Отзывы: