background image

STANDARD/OPTIONAL ACCESSORIES

& MAINTENANCE

MAINTAINING YOUR VACUUM AND ACCESSORIES

Warning! To reduce the risk of injury and electrical shock, unplug the power cord from
the power source. Airborn dust will be produced when cleaning, wear dust mask!

To maintain peak vacuum performance, the foam and re-usable filters must be cleaned often.
When not in use, wrap the power cord around the power cord posts (top handle).

Filter maintenance

- Clean the foam filter and re-usable filter by washing them inside out in a mild

soapy water and then rince with clean water, see Fig.17. Clean optional cartridge filter in a mild
soapy water and then rince with clean water. Allow these filters to dry completely before using.

Blower foam pad maintenance

- After using the detachable blower, make sure the bottom of the

blower is not blocked by debris or leaves. The blower unit comes with an internal foam pad (A)
Fig.18. If this foam pad needs cleaning, remove the four screws that hold the bottom shield.
Remove bottom shield (B) and the foam pad from the blower unit.Clean the foam pad in a mild
soapy water and then rince with clean water. Allow the foam pad to dry completely before
reinstalling it into the lower unit.

General Maintenance and Inspection

- The inside of the tank, hose, extension wands and

accessories should be cleaned after every use, this cleaning should only be done outdoors with
the power cord disconnected from the power source. Check the condition of the power cord and
make sure it is not damaged. Also check the condition of the filters for tears and small holes. Do
not use filters with tears or small holes, replace with new filters.

TROUBLESHOOTING

Dust comes from the motor cover

-

Place/replace the dust bag if dust bag is missing or damaged or empty the tank.

Reduced efficiency/increased motor speed

-

Inlet is block or tank is full- Unblock inlet or empty tank through tank drain.

FIGURE 17  

Model

KVAC-1010

KVAC-1040

KVAC-1060

KVAC-1070

KVAC-1183

KVAC-1101

KVAC-1103

KVAC-1105

KVAC-1107

KVAC-1111

KVAC-1117

KVAC-1124

KVAC-1125

KVAC-1126

KVAC-1130

KVAC-1132

Description

30L Dust bags- 3pc. kit

Foam Filter- 1pc.

Re-usable Filter- 1pc.

Cartridge Filter- 1pc.

6ft x 1-1/4” hose

1-1/4” Round Brush- 1pc.

1-1/4” Gulper Tool- 1pc.

1-1/4” Crevice Tool- 1pc.

10” x 1-1/4” Floop Sweep- 1pc.

2pc. Extension wand kit

2-1/2” Blower extension

Caster Wheels- 4pc. kit

2-1/2” Cone nozzle

2-1/2” Blower nozzle

High Efficiency Cartridge Filter

30L High Efficiency Dust bags- 3pc. kit

Included/Optional

Optional

1pc. Included

1pc. Included

Optional

1pc. Included

Optional

Optional

1pc. Included

1pc. Included

2pc. kit Included

1pc. Included

4pcs. Included

1pc. Included

1pc. Included

Optional

Optional

Usage

Dry Vacuuming Applications

Wet•Dry Vacuuming Applications

Wet•Dry Vacuuming Applications

Dry Vacuuming Applications

General purpose

Upholstery and car interiors

General purpose

General purpose

General purpose-reversible attachment

General purpose

Blower

Replacement kit

Blower

Blower

Drywall and fine dust applications

Drywall and fine dust applications

STANDARD AND OPTIONAL ACCESSORIES

The following chart lists the standard accessories included and the available optional accessories for this wet•dry vacuum. Please note that
these accessories are not covered under warranty and are available at your nearest King Canada distributor.

FIGURE 18  

PARTS DIAGRAM & PARTS LISTS

Refer to the Parts section of the King Canada web site for the most updated parts diagram and parts list.

Содержание 8531LP-B

Страница 1: ...INSTRUCTION MANUAL COPYRIGHT 2009 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL 8531LP B W We et t Dr Dry Blo y Blow wer er V Vac ac WET DRY VACUUM WITH DETACHABLE BLOWER ...

Страница 2: ...s that specified on the nameplate A power source with voltage greater than the specified voltage on nameplate can result in SERIOUS INJURY to the user as well as damage to the motor If in doubt DO NOT PLUG IN THE VACUUM Using a power source with voltage less than the nameplate is also harmful to the motor 1 KNOW YOUR VACUUM Read and understand the owners manual and labels affixed to the vacuum Lea...

Страница 3: ...per use of extension cords may cause inefficient operation of your tool which can result in overheating Be sure your extension cord is rated to allow sufficient current flow to the motor If you are using the tool outdoors use an extension cord rated for outdoor use signified by WA on the jacket The extension cord must have a minimum wire size depending on the amperage of the tool and the length of...

Страница 4: ...flow The re usable filter can and should be used together with the foam filter Install optional cartridge filter instead of both other filters when vacuuming coarse and dusty materials Place the cover motor assembly upside down slide the foam filter A Fig 5 or optional cartridge filter over the cage B If you installed the foam filter then slide the re usable filter over the foam filter Now an opti...

Страница 5: ... When vacuuming fine dust it will be necessary to clean the foam re usable and optional cartridge filters at more frequent intervals WET VACUUMING OPERATIONAL STEPS Before vacuuming wet materials it is important that you have read and understood the safety rules in this manual 1 Unplug the power cord from the power source 2 Install a clean and dry foam filter If wet vacuuming under normal conditio...

Страница 6: ...r source and proceed USING THE DETACHABLE BLOWER This 8 gallon US Wet Dry Vacuum converts into a detachable leaf blower to use the detachable blower 1 Make sure the vacuum is in the Off 0 position and unplug the power cord from the power source 2 Remove the noise diffuser A Fig 15 from the blower outlet 3 Grasp the top handle and press the blower release button B and lift the detachable blower uni...

Страница 7: ...h new filters TROUBLESHOOTING Dust comes from the motor cover Place replace the dust bag if dust bag is missing or damaged or empty the tank Reduced efficiency increased motor speed Inlet is block or tank is full Unblock inlet or empty tank through tank drain FIGURE 17 Model KVAC 1010 KVAC 1040 KVAC 1060 KVAC 1070 KVAC 1183 KVAC 1101 KVAC 1103 KVAC 1105 KVAC 1107 KVAC 1111 KVAC 1117 KVAC 1124 KVAC...

Отзывы: