ASSEMBLY

BLOWER MODE

Align the grooves on the blower tube (A) Fig.4 with the grooves on the blower
outlet (B). Push the blower tube onto the blower outlet until it clicks into
position. 

Warning!

The blower inlet and outlet both have a built-in limit switch which

prevents the blower from starting if the blower tube (A) and the blower inlet
safety guard (C) are not installed or not installed properly. Make sure the
blower tube and blower inlet safety guard are installed before attempting to use
the blower.  

To install the blower inlet safety guard (A) Fig.5 to the blower inlet, position the
blower inlet safety guard over the blower inlet, rotate the safety guard
approximately 90 degrees. Make sure the safety guard has engaged the
blower inlet grooves, at this point you must not be able to lift the safety guard
upwards. Make sure the limit switch actuator (B) engages the inner limit switch,
then lock the blower inlet safety guard using the locking clip (C). The blower is
now ready to use, make sure you have read and understood the safety and
operation instructions before using.

It is recommended to install the adjustable shoulder strap (D) Fig.4 to the
blower handle (E).

VACUUM/MULCHER MODE

Warning!

The vacuum/mulcher inlet and outlet both have a built-in limit switch

which prevents the vacuum/mulcher from starting if the main collection tube
(A) Fig.6 and the collection bag attachment (C) are not installed or not installed
properly. Make sure the vacuum/mulcher main collection tube and the
collection bag attachment are installed before attempting to use the
vacuum/mulcher.

In vacuum/mulcher mode, the main collection tube (A) Fig.6, lower section
collection tube (B) and the collection bag attachment (C) with collection bag
must be installed. First, remove the blower inlet safety guard (A) Fig.5 (if
installed). Then install the main collection tube (A) to the vacuum/mulcher inlet,
position the main collection tube over the vacuum/mulcher inlet, rotate the
collection tube approximately 90 degrees. Make sure the collection tube has
engaged the vacuum/mulcher inlet grooves, at this point you must not be able
to lift the collection tube upwards. Make sure the limit switch actuator  engages
the inner limit switch, then lock the collection tube using the locking clip (refer
to “B” & “C” Fig.5). 

Install the lower section collection tube (B) Fig.6 to the main collection tube (A).
Align the grooves on both collection tubes and push them together until they
click into position.

Then install the collection bag and attachment (C) Fig.6 to the vacuum/mulcher
outlet (D). Align the grooves on the collection bag attachment with the grooves
on the vacuum/mulcher outlet. Push the collection bag attachment onto the
vacuum/mulcher outlet until it clicks into position. Attach the collection bag
buckle to the clip on the lower section collection tube. The vacuum/mulcher is
now ready to use, make sure you have read and understood the safety and operation instructions before using.

It is recommended to install the adjustable shoulder strap (D) Fig.4 to the vacuum/mulcher handle (E).

FIGURE 4

FIGURE 5

FIGURE 6

Содержание 8500BVM

Страница 1: ...3 IN 1 VARIABLE SPEED BLOWER VACUUM MULCHER INSTRUCTION MANUAL COPYRIGHT 2010 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL 8500BVM ...

Страница 2: ...ccidents repairs done by an unauthorized service center alterations and lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To take advantage of this limited warranty return the product at your expense together with your dated proof of purshase to an authorized ...

Страница 3: ...tended function Check for alignment of moving parts binding of moving parts breakage of parts mounting and any other conditions that may affect its operation A guard or other parts that are damaged should be properly repaired or replaced 17 NEVER LEAVE MACHINE RUNNING UNATTENDED TURN POWER OFF Don t leave any tool running until it comes to a complete stop SPECIFIC SAFETY RULES 1 Make sure your ext...

Страница 4: ... safety guard To operate in blower mode it must be installed to the blower air inlet 7 Main vacuum mulcher collection tube with handle To operate in vacuum mulcher mode it must be installed to the blower air inlet 8 Lower section of vacuum mulcher collection tube 9 Washable leaf collection bag 10 Leaf collection bag attachment 11 Blower vacuum mulcher motor 12 On Off switch MODEL 8500BVM Air speed...

Страница 5: ...cian to install the proper outlet Do not modify the tool plug or extension cord in any way USE PROPER EXTENSION CORD Make sure the extension cord is in good condition When using an extension cord be sure to use one heavy enough to carry the current your tool will draw An undersized cord will cause a drop in line voltage resulting in loss of power and overheating See Fig 2 for table showing correct...

Страница 6: ...ure the vacuum mulcher main collection tube and the collection bag attachment are installed before attempting to use the vacuum mulcher In vacuum mulcher mode the main collection tube A Fig 6 lower section collection tube B and the collection bag attachment C with collection bag must be installed First remove the blower inlet safety guard A Fig 5 if installed Then install the main collection tube ...

Страница 7: ... the On position to start In a sweeping motion move the blower side to side advancing slowing keeping the leaves grass etc in front of you Once all debris is in a pile you can now convert your blower to vacuum mulcher mode to collect the debris for disposal In Vacuum Mulcher Mode Tilt the vacuum mulcher tube slightly and use a sweeping motion move the vacuum mulcher tube side to side and turn the ...

Страница 8: ...ed inside the blower vacuum mulcher When used properly with dry leaves the impeller housing should remain clean If damp earth and debris are vacuumed some of the particles may build up on the inside of the impeller housing If this happens the performance of the unit will decrease This area can be cleaned out by gently wiping out with a damp rag after disconnecting from the power source Your blower...

Отзывы: