King Canada 8500BVM Скачать руководство пользователя страница 5

ELECTRICAL INFORMATION

WARNING!

ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN
SERIOUS INJURY! ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THIS POWER TOOL DISCONNECTED FROM THE
POWER SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!

POWER SUPPLY

WARNING:

YOUR BLOWER/VACUUM/MULCHER IS WIRED AT THE FACTORY FOR 110-120V

OPERATION, IT MUST BE CONNECTED TO A 110-120V/15-AMP. TIME DELAY FUSE OR
CIRCUIT BREAKER. FAILURE TO CONNECT IN THIS WAY CAN RESULT IN INJURY FROM
SHOCK OR FIRE. This Blower/Vacuum/Mulcher is intended for use with a polarized 2 wire or 3 wire
extension cord having an outlet and a plug which looks like the one illustrated in Fig.1.

SAFETY WARNINGS AND INSTRUCTIONS: POLARIZED PLUG

To reduce the risk of electric shock, this Blower/Vacuum/Mulcher comes with a polarized 120V plug
(one blade is wider than the other). It must be used with a suitable polarized 2 wire or 3 wire
extension cord. Polarized connections will fit together only one way. Make sure that the receptacle
end of the extension cord has large and small blade slot widths. If the plug does not fit fully into the
extension cord, reverse the plug. If it still does not fit, obtain a suitable extension cord. If the extension cord does not fit fully in the outlet,
contact a qualified electrician to install the proper outlet. Do not modify the tool plug or extension cord in any way.

USE PROPER EXTENSION CORD

Make sure the extension cord is in good condition. When using an extension cord, be sure to use one
heavy enough to carry the current your tool will draw. An undersized cord will cause a drop in line
voltage resulting in loss of power and overheating. See Fig.2 for table showing correct size to use
depending on the cord lenght and the nameplate amperage rating. If in doubt, use the next heavier
gauge. The smaller the gauge number, the heavier the cord. Always use U.L. or CSA listed extension
cords.

WARNING: 

Replace damaged cords immediately. Use of damaged cords can shock, burn or

electrocute.

CONNECTING THE POWER CORD TO EXTENSION CORD

Secure the extension cord (A) Fig.3 to the extension cord lock (B) on the motor housing. First
bend the end of the extension cord and then pass it through the cord lock opening (C). Then
slip the extension cord around the “T” notch cord lock (B) and pull on the extension cord to get
a tight fit. This will prevent accidental unplugging of the extension cord during use. Then plug
the female end of the extension cord into the tool’s polarized plug.

WARNING!

To reduce risk of electric shock, do not expose to rain, do not use on wet surfaces.

Store indoors.

FIGURE 2

Tool’s

Amperage

Rating

3-6
6-8

8-10

10-12
12-16

Cord Size in A.W.G.

Cord Length in Feet

25

50

100 150

18

16

16

14

18

16

14

12

18

16

14

12

18

16

14

12

14

12

-

-

FIGURE 1

Polarized 

power outlet

Polarized 

extension cord

FIGURE 3

Содержание 8500BVM

Страница 1: ...3 IN 1 VARIABLE SPEED BLOWER VACUUM MULCHER INSTRUCTION MANUAL COPYRIGHT 2010 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL 8500BVM ...

Страница 2: ...ccidents repairs done by an unauthorized service center alterations and lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To take advantage of this limited warranty return the product at your expense together with your dated proof of purshase to an authorized ...

Страница 3: ...tended function Check for alignment of moving parts binding of moving parts breakage of parts mounting and any other conditions that may affect its operation A guard or other parts that are damaged should be properly repaired or replaced 17 NEVER LEAVE MACHINE RUNNING UNATTENDED TURN POWER OFF Don t leave any tool running until it comes to a complete stop SPECIFIC SAFETY RULES 1 Make sure your ext...

Страница 4: ... safety guard To operate in blower mode it must be installed to the blower air inlet 7 Main vacuum mulcher collection tube with handle To operate in vacuum mulcher mode it must be installed to the blower air inlet 8 Lower section of vacuum mulcher collection tube 9 Washable leaf collection bag 10 Leaf collection bag attachment 11 Blower vacuum mulcher motor 12 On Off switch MODEL 8500BVM Air speed...

Страница 5: ...cian to install the proper outlet Do not modify the tool plug or extension cord in any way USE PROPER EXTENSION CORD Make sure the extension cord is in good condition When using an extension cord be sure to use one heavy enough to carry the current your tool will draw An undersized cord will cause a drop in line voltage resulting in loss of power and overheating See Fig 2 for table showing correct...

Страница 6: ...ure the vacuum mulcher main collection tube and the collection bag attachment are installed before attempting to use the vacuum mulcher In vacuum mulcher mode the main collection tube A Fig 6 lower section collection tube B and the collection bag attachment C with collection bag must be installed First remove the blower inlet safety guard A Fig 5 if installed Then install the main collection tube ...

Страница 7: ... the On position to start In a sweeping motion move the blower side to side advancing slowing keeping the leaves grass etc in front of you Once all debris is in a pile you can now convert your blower to vacuum mulcher mode to collect the debris for disposal In Vacuum Mulcher Mode Tilt the vacuum mulcher tube slightly and use a sweeping motion move the vacuum mulcher tube side to side and turn the ...

Страница 8: ...ed inside the blower vacuum mulcher When used properly with dry leaves the impeller housing should remain clean If damp earth and debris are vacuumed some of the particles may build up on the inside of the impeller housing If this happens the performance of the unit will decrease This area can be cleaned out by gently wiping out with a damp rag after disconnecting from the power source Your blower...

Отзывы: