background image

MAINTENANCE & STORAGE

MAINTENANCE

Before doing any maintenance or adjustments to your air compressor,
the following safety precautions should be taken:
- Disconnect electrical power.
- Drain air tank of pressure.

Daily or before each use

1. Check oil level. Oil level should be centered with the red dot.
2. Drain condensation from tank.
3. Check for any unusual noise or vibration.
4. Be sure all nuts and bolts are tight.

Monthly

1. Inspect air system for leaks by applying soapy water to all joints.

Tighten those joints if leakage is observed.

250 hours or six months (whichever comes first)

1. Change compressor oil. See following instructions.
2. Replace oil more often if compressor is used near paint spraying

operations or in dusty environments.

CHANGING OIL

To change oil, oil must be drained from the crankcase by removing oil
sight glass (C) Fig.7. Drain oil and replace oil sight glass. To fill the
crank case with oil (approx. 450ml), first unscrew and remove oil
breather cap (A), pour air compressor oil (SAE 30 weight non-detergent
oil) into crankcase oil opening (B) until the oil level reaches the center
red dot on the oil sight glass (C). Retighten oil breather cap (A).

KEEP TOOL CLEAN

Periodically blow out all air passages with dry compressed air. Clean all
plastic parts with a soft damp cloth. NEVER use solvents to clean
plastic parts. They could possibly dissolve or otherwise damage the
material.

CAUTION

: Wear safety glasses while using compressed air.

FAILURE TO START

Should your compressor fail to start, check to make sure the prongs on
the cord plug are making good contact in the outlet. Also, check for
blown fuses or open circuit breakers in the line. If using an extension
cord, try using a longer air hose instead and try to start compressor
again.

STORAGE

1. Set the “OFF/AUTO” button to “OFF”.
2. Lift and turn the regulator counterclockwise to set the outlet pressure

to zero. 

3. Remove the air tool or accessory .
4. Pull ring on safety valve (H) Fig. 5, allowing air to bleed from the

tank, until tank pressure is approximately 20psi. Release safety
valve ring.

5. Drain water from air tank. Turn drain valve (B) Fig. 4, counterclock-

wise, to open.

NOTE: If drain valve is plugged, pull ring on safety valve (H) Fig. 5, and

hold until air pressure has been released. The valve can then be
removed, cleaned, and reinstalled.

6. After the water has been completely drained, turn drain valve to
close. The air compressor can now be stored. 
7. Protect the electrical cord and air hose from damage by winding

them loosely around the air compressor.

8. Store the air compressor in a clean and dry location.

FIGURE 7

TROUBLE

No start condition

Low pressure

Safety valve releasing

Oil discharge in air

POSSIBLE CAUSE

Fuse blown or circuit breaker tripped
Loose electrical connections
Overheated motor

Air leak in safety valve

Restricted air filter
Defective check valve

Defective pressure switch or improper
adjustment

Improper oil viscosity
Too much oil in crankcase
Compressor overheated
Restricted air filter

CORRECTIVE ACTION

Check voltage or eliminate extension cord or reset
Check wiring connections
Press the reset button or wait for automatic reset

Check valve manually by pulling upwards on ring. If condition
persists replace valve
Clean or replace as necessary
Replace check valve

Check for proper adjustment and if problem persists, replace
pressure switch

Replace oil with SAE 30 oil
Drain crankcase and fill to proper level
Air pressure regulated too high
Replace filter

TROUBLE SHOOTING

Содержание 8498

Страница 1: ...INSTRUCTION MANUAL COPYRIGHT 2006 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL 8498 5 PEAK HP 20 GALLON AIR COMPRESSOR plus plus performance performance...

Страница 2: ...umer a 2 year limited warranty as of the date the product was purchased at retail and that each product is free from defects in materials Warranty does not apply to defects due directly or indirectly...

Страница 3: ...nk 3 Unauthorized modifications to the unloader valve safety valve or any other components which control tank pressure 4 Excessive vibration can weaken the air tank and cause rupture or explosion Atta...

Страница 4: ...es WARNING TO MAINTAIN PROPER GROUNDING DO NOT REMOVE OR ALTER THE GROUNDING PRONG IN ANY MANNER 110V OPERATION As received from the factory your compressor is ready to run for 110V operation This mac...

Страница 5: ...AUGE G FIG 5 The tank pressure gauge indicates the air pressure in the tank COOLING SYSTEM This compressor contains an advanced design cooling system The cooling system is working when air is being ex...

Страница 6: ...VALVE AND WHEN THE PISTON OR THE CYLINDER SLEEVE IS REPLACED A Set the pressure switch to the OFF position B Plug the power cord into the correct branch circuit receptacle C Turn the drain valve B Fig...

Страница 7: ...rs in the line If using an extension cord try using a longer air hose instead and try to start compressor again STORAGE 1 Set the OFF AUTO button to OFF 2 Lift and turn the regulator counterclockwise...

Отзывы: