SPECIFICATIONS & 

ELECTRICAL INFORMATION

WARNING

ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN
SERIOUS INJURY! ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE COMPRESSOR DISCONNECTED FROM THE
POWER SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!

POWER SUPPLY

WARNING:

YOUR COMPRESSOR MUST BE CONNECTED TO A 120V

WALL OUTLET, WITH A MINIMUM 15-AMP. BRANCH CIRCUIT AND
USE A 15-AMP TIME DELAY FUSE OR CIRCUIT BREAKER. FAILURE
TO CONNECT IN  THIS WAY CAN RESULT IN INJURY FROM SHOCK
OR FIRE.

GROUNDING

Your compressor must be properly grounded. Not all outlets are properly
grounded. If you are not sure if your outlet is properly grounded, have it
checked by a qualified electrician.

WARNING:

IF NOT PROPERLY GROUNDED, THIS COMPRESSOR

CAN CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN USED IN
DAMP LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER CORD
IS WORN OR DAMAGED IN ANY WAY, HAVE IT REPLACED
IMMEDIATELY.

If this compressor should malfunction or breakdown, grounding provides a
path of least resistance for electric current, to reduce the risk of electric
shock.  This compressor is equipped with a cord having an equipment-
grounding conductor and grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in accordance
with all local codes and ordinances.

WARNING: 

TO MAINTAIN PROPER GROUNDING, DO NOT REMOVE OR

ALTER THE GROUNDING PRONG IN ANY MANNER.

120V OPERATION

As received from the factory, your compressor is ready to run for 120V
operation. This machine is intended for use on a circuit that has an outlet
and a plug which looks like the one illustrated in Fig.1.

WARNING:

DO NOT USE A TWO-PRONG ADAPTOR(S) FOR THEY ARE

NOT IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES.
NEVER USE IN CANADA.

FIGURE 1

LENGTH OF

CONDUCTOR

0-25 FEET

26-50 FEET

51-100 FEET

WIRE SIZES REQUIRED

(AMERICAN WIRE GAUGE)

110V LINES

NO.14
NO.12

Not recommended

FIGURE 2

EXTENSION CORDS

The use of any extension cord will cause some loss of power. IT
IS RECOMMENDED TO USE A LONGER AIR HOSE INSTEAD
OF AN EXTENSION CORD. If you do not have a choice, use the
table in Fig.2 to determine the minimum wire size (A.W.G-
American Wire Gauge) extension cord needed. Use only 3-wire
extension cords which have 3-prong grounding type plugs and 3-
hole receptacles which accept the tool’s plug.

For circuits that are further away from the electrical circuit box, the
wire size must be increased proportionately in order to deliver
ample voltage to the air compressor motor. Refer to Fig.2 for wire
length and size.

PROPERLY GROUNDED OUTLET

CURRENT CARRYING
PRONGS

GROUNDING
PRONG

SPECIFICATIONS

Model

............................................................................................................................................................................................8449N

Voltage

............................................................................................................................................................................................120V

Horsepower

......................................................................................................................................................................................1.5

Amperage

......................................................................................................................................................................................12.5A

RPM (no load speed)

....................................................................................................................................................................3400

Phase

....................................................................................................................................................................................................1

Hertz

..............................................................................................................................................................................................60Hz

Operating pressure

..................................................................................................................................................................115 PSI

CFM @ 40 PSI

................................................................................................................................................................................2.76

CFM @ 90 PSI

................................................................................................................................................................................2.30

Tank size

..................................................................................................................................................................................2 Gallon

Содержание 8449N

Страница 1: ...KING CANADA INSTRUCTION MANUAL COPYRIGHT 2010 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL 8449N 1 5 HP AIR COMPRESSOR plus plus performance performance...

Страница 2: ...nts repairs done by an unauthorized service center alterations and lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental special or co...

Страница 3: ...nk 3 Unauthorized modifications to the unloader valve safety valve or any other components which control tank pressure 4 Excessive vibration can weaken the air tank and cause rupture or explosion Atta...

Страница 4: ...nce with all local codes and ordinances WARNING TO MAINTAIN PROPER GROUNDING DO NOT REMOVE OR ALTER THE GROUNDING PRONG IN ANY MANNER 120V OPERATION As received from the factory your compressor is rea...

Страница 5: ...moval should be used where applicable OPERATION CONTROLS AIR COMPRESSOR PUMP To compress air the piston moves up and down in the cylinder On the downstroke air is drawn in through the intake valves Th...

Страница 6: ...cutout pressure setting the safety valve will protect against high pressure by popping out at it s factory set pressure slightly higher than the pressure switch cut out setting WARNING If the safety v...

Страница 7: ...sure Daily or before each use 1 Check oil level Oil level must be in the centre of the red dot of oil sight glass 2 Drain condensation from tank 3 Check for any unusual noise or vibration 4 Be sure al...

Страница 8: ...Check for cause of blown fuse breaker and replace or reset Check wiring connections Press the reset button or wait for automatic reset Check valve manually by pulling upwards on ring If condition pers...

Отзывы: